P 1165

P 1165
technical infos

Average fill factor

  • 0.67

average spinning loss factor

  • 0.802

Core

  • steel core

Lay direction

  • choice of right hand or left hand

Compacting

  • strands compacted – thereby extra wear resistant

Finish

  • choice of bright or galvanised

Rope diameter tolerance

  • +1/+4%

Indication

  • Please refer to our operating manual stranded ropes! Available at www.pfeifer.info/manual-strand-ropes

  • Sample schematic of rope construction used for representative purposes only. Actual construction dependent upon rope diameter.
Safety

WARNING: Never use with a swivel – failure to comply may result in serious damages and injuries!
Product variants
Nominal rope Ø [mm]
Minimum breaking force Fmin 1770 [kN]
Minimum breaking force Fmin 1960 [kN]
Minimum breaking force Fmin 2160 [kN]
Details
  • 12
    112
    124
    131
    Nominal rope Ø [mm] 12
    Weight approx. 68.3 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 112
    Minimum breaking force Fmin 1960 [kN] 124
    Minimum breaking force Fmin 2160 [kN] 131
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 13
    131
    147
    157
    Nominal rope Ø [mm] 13
    Weight approx. 79.2 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 131
    Minimum breaking force Fmin 1960 [kN] 147
    Minimum breaking force Fmin 2160 [kN] 157
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 14
    153
    169
    183
    Nominal rope Ø [mm] 14
    Weight approx. 93 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 153
    Minimum breaking force Fmin 1960 [kN] 169
    Minimum breaking force Fmin 2160 [kN] 183
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 15
    176
    194
    208
    Nominal rope Ø [mm] 15
    Weight approx. 106 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 176
    Minimum breaking force Fmin 1960 [kN] 194
    Minimum breaking force Fmin 2160 [kN] 208
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 16
    198
    219
    237
    Nominal rope Ø [mm] 16
    Weight approx. 119 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 198
    Minimum breaking force Fmin 1960 [kN] 219
    Minimum breaking force Fmin 2160 [kN] 237
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 18
    250
    277
    298
    Nominal rope Ø [mm] 18
    Weight approx. 152 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 250
    Minimum breaking force Fmin 1960 [kN] 277
    Minimum breaking force Fmin 2160 [kN] 298
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 19
    275
    305
    329
    Nominal rope Ø [mm] 19
    Weight approx. 168 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 275
    Minimum breaking force Fmin 1960 [kN] 305
    Minimum breaking force Fmin 2160 [kN] 329
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 20
    307
    340
    368
    Nominal rope Ø [mm] 20
    Weight approx. 185 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 307
    Minimum breaking force Fmin 1960 [kN] 340
    Minimum breaking force Fmin 2160 [kN] 368
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 22
    370
    410
    441
    Nominal rope Ø [mm] 22
    Weight approx. 226 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 370
    Minimum breaking force Fmin 1960 [kN] 410
    Minimum breaking force Fmin 2160 [kN] 441
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 24
    447
    492
    540
    Nominal rope Ø [mm] 24
    Weight approx. 274 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 447
    Minimum breaking force Fmin 1960 [kN] 492
    Minimum breaking force Fmin 2160 [kN] 540
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 26
    520
    581
    622
    Nominal rope Ø [mm] 26
    Weight approx. 314 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 520
    Minimum breaking force Fmin 1960 [kN] 581
    Minimum breaking force Fmin 2160 [kN] 622
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 28
    604
    663
    722
    Nominal rope Ø [mm] 28
    Weight approx. 368 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 604
    Minimum breaking force Fmin 1960 [kN] 663
    Minimum breaking force Fmin 2160 [kN] 722
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 30
    689
    763
    831
    Nominal rope Ø [mm] 30
    Weight approx. 421 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 689
    Minimum breaking force Fmin 1960 [kN] 763
    Minimum breaking force Fmin 2160 [kN] 831
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 32
    777
    861
    949
    Nominal rope Ø [mm] 32
    Weight approx. 475 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 777
    Minimum breaking force Fmin 1960 [kN] 861
    Minimum breaking force Fmin 2160 [kN] 949
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 34
    891
    980
    1070
    Nominal rope Ø [mm] 34
    Weight approx. 545 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 891
    Minimum breaking force Fmin 1960 [kN] 980
    Minimum breaking force Fmin 2160 [kN] 1070
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 36
    992
    1130
    1192
    Nominal rope Ø [mm] 36
    Weight approx. 609 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 992
    Minimum breaking force Fmin 1960 [kN] 1130
    Minimum breaking force Fmin 2160 [kN] 1192
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 38
    1101
    1220
    1328
    Nominal rope Ø [mm] 38
    Weight approx. 665 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1101
    Minimum breaking force Fmin 1960 [kN] 1220
    Minimum breaking force Fmin 2160 [kN] 1328
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 40
    1222
    1353
    1455
    Nominal rope Ø [mm] 40
    Weight approx. 743 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1222
    Minimum breaking force Fmin 1960 [kN] 1353
    Minimum breaking force Fmin 2160 [kN] 1455
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 44
    1441
    1595
    1736
    Nominal rope Ø [mm] 44
    Weight approx. 887 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1441
    Minimum breaking force Fmin 1960 [kN] 1595
    Minimum breaking force Fmin 2160 [kN] 1736
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 48
    1707
    1891
    2045
    Nominal rope Ø [mm] 48
    Weight approx. 1051 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1707
    Minimum breaking force Fmin 1960 [kN] 1891
    Minimum breaking force Fmin 2160 [kN] 2045
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 50
    1853
    2052
    2219
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 12
Minimum breaking force Fmin 1770 [kN] 112
Minimum breaking force Fmin 1960 [kN] 124
Minimum breaking force Fmin 2160 [kN] 131
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 13
Minimum breaking force Fmin 1770 [kN] 131
Minimum breaking force Fmin 1960 [kN] 147
Minimum breaking force Fmin 2160 [kN] 157
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 14
Minimum breaking force Fmin 1770 [kN] 153
Minimum breaking force Fmin 1960 [kN] 169
Minimum breaking force Fmin 2160 [kN] 183
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 15
Minimum breaking force Fmin 1770 [kN] 176
Minimum breaking force Fmin 1960 [kN] 194
Minimum breaking force Fmin 2160 [kN] 208
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 16
Minimum breaking force Fmin 1770 [kN] 198
Minimum breaking force Fmin 1960 [kN] 219
Minimum breaking force Fmin 2160 [kN] 237
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 18
Minimum breaking force Fmin 1770 [kN] 250
Minimum breaking force Fmin 1960 [kN] 277
Minimum breaking force Fmin 2160 [kN] 298
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 19
Minimum breaking force Fmin 1770 [kN] 275
Minimum breaking force Fmin 1960 [kN] 305
Minimum breaking force Fmin 2160 [kN] 329
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 20
Minimum breaking force Fmin 1770 [kN] 307
Minimum breaking force Fmin 1960 [kN] 340
Minimum breaking force Fmin 2160 [kN] 368
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 22
Minimum breaking force Fmin 1770 [kN] 370
Minimum breaking force Fmin 1960 [kN] 410
Minimum breaking force Fmin 2160 [kN] 441
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 24
Minimum breaking force Fmin 1770 [kN] 447
Minimum breaking force Fmin 1960 [kN] 492
Minimum breaking force Fmin 2160 [kN] 540
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 26
Minimum breaking force Fmin 1770 [kN] 520
Minimum breaking force Fmin 1960 [kN] 581
Minimum breaking force Fmin 2160 [kN] 622
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 28
Minimum breaking force Fmin 1770 [kN] 604
Minimum breaking force Fmin 1960 [kN] 663
Minimum breaking force Fmin 2160 [kN] 722
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 30
Minimum breaking force Fmin 1770 [kN] 689
Minimum breaking force Fmin 1960 [kN] 763
Minimum breaking force Fmin 2160 [kN] 831
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 32
Minimum breaking force Fmin 1770 [kN] 777
Minimum breaking force Fmin 1960 [kN] 861
Minimum breaking force Fmin 2160 [kN] 949
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 34
Minimum breaking force Fmin 1770 [kN] 891
Minimum breaking force Fmin 1960 [kN] 980
Minimum breaking force Fmin 2160 [kN] 1070
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 36
Minimum breaking force Fmin 1770 [kN] 992
Minimum breaking force Fmin 1960 [kN] 1130
Minimum breaking force Fmin 2160 [kN] 1192
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 38
Minimum breaking force Fmin 1770 [kN] 1101
Minimum breaking force Fmin 1960 [kN] 1220
Minimum breaking force Fmin 2160 [kN] 1328
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 40
Minimum breaking force Fmin 1770 [kN] 1222
Minimum breaking force Fmin 1960 [kN] 1353
Minimum breaking force Fmin 2160 [kN] 1455
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 44
Minimum breaking force Fmin 1770 [kN] 1441
Minimum breaking force Fmin 1960 [kN] 1595
Minimum breaking force Fmin 2160 [kN] 1736
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 48
Minimum breaking force Fmin 1770 [kN] 1707
Minimum breaking force Fmin 1960 [kN] 1891
Minimum breaking force Fmin 2160 [kN] 2045
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 50
Minimum breaking force Fmin 1770 [kN] 1853
Minimum breaking force Fmin 1960 [kN] 2052
Minimum breaking force Fmin 2160 [kN] 2219
  • Details
    Nominal rope Ø [mm] 50
    Weight approx. 1141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1853
    Minimum breaking force Fmin 1960 [kN] 2052
    Minimum breaking force Fmin 2160 [kN] 2219
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Other rope diameters and constructions on enquiry.
Downloads
Contact
Market Contact Location type
All other markets
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-301
Fax +49 8331 937-123
E-Mail wireropes@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Germany
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-181
Fax +49 8331 937-123
E-Mail seile@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Oktjaborskaja Nabereschnaja, No. 104, Korpus 23
RU-193079 St. Petersburg
Tel. +7 812 740 12-24
Fax +7 812 493 48-21
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Service centre
USA
PFEIFER Wire Rope & Lifting Technology Inc.
2023 Humble Westfield
US-Houston, TX 77037
Tel. +1 832 827 2923
Fax +1 281 784 2903
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Service centre
Austria
PFEIFER Seil- und Hebetechnik GmbH
Harterfeldweg 2
AT-4481 Asten
Tel. +43 7224 662 24-0
Fax +43 7224 662 24-13
E-Mail info@pfeifer-austria.at
Web www.pfeifer-austria.at
Sales subsidiary
China
PFEIFER Steel Wire Rope (Shanghai) Co., Ltd.
Building 1, No. 366 Chen Xiang Road, Nanxiang Town, Jiading District
CN-Shanghai 201802
Industrieseile/Industry ropes
Tel. +86 21 56 77 80 06
Fax +86 21 56 77 92 29
E-Mail info@pfeifer.com.cn
Web www.pfeifer.com.cn
Sales subsidiary
Great Britain
PFEIFER Rope & Tackle Ltd.
Unit 1A1, Marchwood Industrial Park, North Road
GB-Southampton SO40 4BL
Tel. +44 23 8066-5470
Fax +44 23 8066-5471
E-Mail sales@ropeandtackle.com
Web www.pfeifer-rt.com
Sales subsidiary
Hungary
PFEIFER Garant Kft.
Gyömrői út 108-126
HU-1103 Budapest
Tel. +36 1 260 10 14
Fax +36 1 262 09 27
E-Mail info@pfeifer-garant.hu
Web www.pfeifer-garant.hu
Sales subsidiary
Luxemburg
PFEIFER SOGEQUIP S.à.r.l.
Zone Ind. Schifflange-Foetz
LU-3844 Schifflange
Tel. +352 57 42-42
Fax +352 57 42-62
E-Mail info@pfeifer-sogequip.lu
Web www.pfeifer-sogequip.lu
Sales subsidiary
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Pyzhevskiy pereulok, h. 5, bld.1, office 108
RU-119017 Moskau
Tel. +7 495 363 01-27
Fax +7 495 363 01-28
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Sales subsidiary
Spain
PFEIFER Cables y Equipos de Elevación S.L.
Avda. de los Pirineos, 25 – Nave 20, San Sebastián de los Reyes
ES-28703 Madrid
Tel. +34 91 659-3185
Fax +34 91 659-3139
E-Mail p-es@pfeifer.es
Web www.pfeifer.es
Sales subsidiary
USA
PFEIFER Wire Rope & Lifting Technology Inc.
600 Industry Drive
US-Hampton, VA 23661
Tel. +1 757 825 2544
Fax +1 757 825 2546
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Sales subsidiary
United Arab Emirates
PFEIFER Middle East Wire Rope & Lifting Technology FZE
Jebel Ali Free Zone 1, RA08UA07, PO Box 263081
AE-Dubai
Tel. +971 4 883-8445
Fax +971 4 883-8446
E-Mail sales@pfeifer.ae
Web rope-lifting-ae.pfeifer.info
Sales subsidiary
Germany
PFEIFER Seil- und Hebetechnik GmbH
Krönenbarg 92b
DE-21077 Hamburg
Tel. +49 40 78 04 63-0
Fax +49 40 78 70 13
E-Mail psh-hamburg@pfeifer.de
Web www.pfeifer.info
Office
Switzerland
pewag Suisse AG
Hasentalstrasse 8
CH-8934 Knonau
Tel. +41 44 768 55-55
Fax +41 44 768 55-30
E-Mail info@pewag-suisse.ch
Web www.pewag-suisse.ch
Agency

Feel free to contact us

Tel.

+49 8331 937-301

Inquiry

please leave empty!
* Required fields

Cookie settings

We use cookies to optimise our web page for you. By continuing to use the web page you agree to the use of cookies. Further information about cookies can be found in our data protection declaration.

Required cookies

Required cookies are mandatory for the basic functions of the website. Without these cookies, you will unfortunately not be able to use our website. These cookies are always set when you use the website. No personal data is collected or stored.

Functional cookies

These cookies allow us to analyze website usage so that we can measure and improve its performance. No personal data is collected or stored.

Data protection declaration