P 102

P 102
technical infos

Average fill factor

  • 0.6441

average spinning loss factor 1770

  • 0.83

average spinning loss factor 1960

  • 0.83

average spinning loss factor 2160

  • 0.81

Core

  • steel core

Lay type

  • lang lay

Lay direction

  • choice of right hand or left hand

Compacting

  • strands compacted – thereby extra wear resistant

Finish

  • choice of bright or galvanised

Rope diameter tolerance

  • 0/+4%

Indication

  • Please refer to our operating manual stranded ropes! Available at www.pfeifer.info/manual-strand-ropes

  • Sample schematic of rope construction used for representative purposes only. Actual construction dependent upon rope diameter.
Product variants
Nominal rope Ø [mm]
Minimum breaking force Fmin 1770 [kN]
Minimum breaking force Fmin 1960 [kN]
Details
  • 6
    26.8
    29.6
    Nominal rope Ø [mm] 6
    Weight approx. 17 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 26.8
    Minimum breaking force Fmin 1960 [kN] 29.6
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 7
    36.4
    40.3
    Nominal rope Ø [mm] 7
    Weight approx. 23 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 36.4
    Minimum breaking force Fmin 1960 [kN] 40.3
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 8
    47.6
    52.7
    Nominal rope Ø [mm] 8
    Weight approx. 30 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 47.6
    Minimum breaking force Fmin 1960 [kN] 52.7
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 9
    60.2
    66.7
    Nominal rope Ø [mm] 9
    Weight approx. 38 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 60.2
    Minimum breaking force Fmin 1960 [kN] 66.7
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 9.2
    63.2
    70.2
    Nominal rope Ø [mm] 9.2
    Weight approx. 39 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 63.2
    Minimum breaking force Fmin 1960 [kN] 70.2
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 10
    74.3
    82.3
    Nominal rope Ø [mm] 10
    Weight approx. 47 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 74.3
    Minimum breaking force Fmin 1960 [kN] 82.3
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 11
    89.9
    99.6
    Nominal rope Ø [mm] 11
    Weight approx. 56 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 89.9
    Minimum breaking force Fmin 1960 [kN] 99.6
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 12
    107
    119
    Nominal rope Ø [mm] 12
    Weight approx. 67 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 107
    Minimum breaking force Fmin 1960 [kN] 119
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 13
    126
    139
    Nominal rope Ø [mm] 13
    Weight approx. 79 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 126
    Minimum breaking force Fmin 1960 [kN] 139
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 14
    146
    161
    Nominal rope Ø [mm] 14
    Weight approx. 91 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 146
    Minimum breaking force Fmin 1960 [kN] 161
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 15
    167
    185
    Nominal rope Ø [mm] 15
    Weight approx. 105 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 167
    Minimum breaking force Fmin 1960 [kN] 185
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 16
    190
    211
    Nominal rope Ø [mm] 16
    Weight approx. 119 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 190
    Minimum breaking force Fmin 1960 [kN] 211
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 17
    215
    238
    Nominal rope Ø [mm] 17
    Weight approx. 135 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 215
    Minimum breaking force Fmin 1960 [kN] 238
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 18
    241
    267
    Nominal rope Ø [mm] 18
    Weight approx. 151 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 241
    Minimum breaking force Fmin 1960 [kN] 267
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 19
    268
    297
    Nominal rope Ø [mm] 19
    Weight approx. 168 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 268
    Minimum breaking force Fmin 1960 [kN] 297
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 20
    297
    329
    Nominal rope Ø [mm] 20
    Weight approx. 186 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 297
    Minimum breaking force Fmin 1960 [kN] 329
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 21
    328
    363
    Nominal rope Ø [mm] 21
    Weight approx. 205 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 328
    Minimum breaking force Fmin 1960 [kN] 363
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 22
    360
    398
    Nominal rope Ø [mm] 22
    Weight approx. 225 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 360
    Minimum breaking force Fmin 1960 [kN] 398
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 23
    393
    435
    Nominal rope Ø [mm] 23
    Weight approx. 246 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 393
    Minimum breaking force Fmin 1960 [kN] 435
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 24
    428
    474
    Nominal rope Ø [mm] 24
    Weight approx. 268 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 428
    Minimum breaking force Fmin 1960 [kN] 474
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 25
    464
    514
    Nominal rope Ø [mm] 25
    Weight approx. 291 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 464
    Minimum breaking force Fmin 1960 [kN] 514
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 26
    502
    556
    Nominal rope Ø [mm] 26
    Weight approx. 315 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 502
    Minimum breaking force Fmin 1960 [kN] 556
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 27
    542
    600
    Nominal rope Ø [mm] 27
    Weight approx. 339 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 542
    Minimum breaking force Fmin 1960 [kN] 600
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 28
    583
    645
    Nominal rope Ø [mm] 28
    Weight approx. 365 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 583
    Minimum breaking force Fmin 1960 [kN] 645
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 29
    625
    692
    Nominal rope Ø [mm] 29
    Weight approx. 391 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 625
    Minimum breaking force Fmin 1960 [kN] 692
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 30
    669
    741
    Nominal rope Ø [mm] 30
    Weight approx. 419 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 669
    Minimum breaking force Fmin 1960 [kN] 741
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 31
    714
    791
    Nominal rope Ø [mm] 31
    Weight approx. 447 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 714
    Minimum breaking force Fmin 1960 [kN] 791
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 32
    761
    843
    Nominal rope Ø [mm] 32
    Weight approx. 477 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 761
    Minimum breaking force Fmin 1960 [kN] 843
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 33
    809
    896
    Nominal rope Ø [mm] 33
    Weight approx. 507 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 809
    Minimum breaking force Fmin 1960 [kN] 896
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 34
    859
    951
    Nominal rope Ø [mm] 34
    Weight approx. 538 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 859
    Minimum breaking force Fmin 1960 [kN] 951
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 35
    910
    1008
    Nominal rope Ø [mm] 35
    Weight approx. 570 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 910
    Minimum breaking force Fmin 1960 [kN] 1008
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 36
    963
    1067
    Nominal rope Ø [mm] 36
    Weight approx. 603 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 963
    Minimum breaking force Fmin 1960 [kN] 1067
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 37
    1018
    1126
    Nominal rope Ø [mm] 37
    Weight approx. 637 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1018
    Minimum breaking force Fmin 1960 [kN] 1126
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 38
    1073
    1189
    Nominal rope Ø [mm] 38
    Weight approx. 672 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1073
    Minimum breaking force Fmin 1960 [kN] 1189
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 39
    1130
    1252
    Nominal rope Ø [mm] 39
    Weight approx. 708 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1130
    Minimum breaking force Fmin 1960 [kN] 1252
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 40
    1189
    1316
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 6
Minimum breaking force Fmin 1770 [kN] 26.8
Minimum breaking force Fmin 1960 [kN] 29.6
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 7
Minimum breaking force Fmin 1770 [kN] 36.4
Minimum breaking force Fmin 1960 [kN] 40.3
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 8
Minimum breaking force Fmin 1770 [kN] 47.6
Minimum breaking force Fmin 1960 [kN] 52.7
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 9
Minimum breaking force Fmin 1770 [kN] 60.2
Minimum breaking force Fmin 1960 [kN] 66.7
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 9.2
Minimum breaking force Fmin 1770 [kN] 63.2
Minimum breaking force Fmin 1960 [kN] 70.2
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 10
Minimum breaking force Fmin 1770 [kN] 74.3
Minimum breaking force Fmin 1960 [kN] 82.3
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 11
Minimum breaking force Fmin 1770 [kN] 89.9
Minimum breaking force Fmin 1960 [kN] 99.6
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 12
Minimum breaking force Fmin 1770 [kN] 107
Minimum breaking force Fmin 1960 [kN] 119
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 13
Minimum breaking force Fmin 1770 [kN] 126
Minimum breaking force Fmin 1960 [kN] 139
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 14
Minimum breaking force Fmin 1770 [kN] 146
Minimum breaking force Fmin 1960 [kN] 161
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 15
Minimum breaking force Fmin 1770 [kN] 167
Minimum breaking force Fmin 1960 [kN] 185
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 16
Minimum breaking force Fmin 1770 [kN] 190
Minimum breaking force Fmin 1960 [kN] 211
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 17
Minimum breaking force Fmin 1770 [kN] 215
Minimum breaking force Fmin 1960 [kN] 238
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 18
Minimum breaking force Fmin 1770 [kN] 241
Minimum breaking force Fmin 1960 [kN] 267
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 19
Minimum breaking force Fmin 1770 [kN] 268
Minimum breaking force Fmin 1960 [kN] 297
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 20
Minimum breaking force Fmin 1770 [kN] 297
Minimum breaking force Fmin 1960 [kN] 329
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 21
Minimum breaking force Fmin 1770 [kN] 328
Minimum breaking force Fmin 1960 [kN] 363
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 22
Minimum breaking force Fmin 1770 [kN] 360
Minimum breaking force Fmin 1960 [kN] 398
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 23
Minimum breaking force Fmin 1770 [kN] 393
Minimum breaking force Fmin 1960 [kN] 435
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 24
Minimum breaking force Fmin 1770 [kN] 428
Minimum breaking force Fmin 1960 [kN] 474
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 25
Minimum breaking force Fmin 1770 [kN] 464
Minimum breaking force Fmin 1960 [kN] 514
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 26
Minimum breaking force Fmin 1770 [kN] 502
Minimum breaking force Fmin 1960 [kN] 556
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 27
Minimum breaking force Fmin 1770 [kN] 542
Minimum breaking force Fmin 1960 [kN] 600
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 28
Minimum breaking force Fmin 1770 [kN] 583
Minimum breaking force Fmin 1960 [kN] 645
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 29
Minimum breaking force Fmin 1770 [kN] 625
Minimum breaking force Fmin 1960 [kN] 692
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 30
Minimum breaking force Fmin 1770 [kN] 669
Minimum breaking force Fmin 1960 [kN] 741
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 31
Minimum breaking force Fmin 1770 [kN] 714
Minimum breaking force Fmin 1960 [kN] 791
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 32
Minimum breaking force Fmin 1770 [kN] 761
Minimum breaking force Fmin 1960 [kN] 843
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 33
Minimum breaking force Fmin 1770 [kN] 809
Minimum breaking force Fmin 1960 [kN] 896
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 34
Minimum breaking force Fmin 1770 [kN] 859
Minimum breaking force Fmin 1960 [kN] 951
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 35
Minimum breaking force Fmin 1770 [kN] 910
Minimum breaking force Fmin 1960 [kN] 1008
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 36
Minimum breaking force Fmin 1770 [kN] 963
Minimum breaking force Fmin 1960 [kN] 1067
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 37
Minimum breaking force Fmin 1770 [kN] 1018
Minimum breaking force Fmin 1960 [kN] 1126
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 38
Minimum breaking force Fmin 1770 [kN] 1073
Minimum breaking force Fmin 1960 [kN] 1189
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 39
Minimum breaking force Fmin 1770 [kN] 1130
Minimum breaking force Fmin 1960 [kN] 1252
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Nominal rope Ø [mm] 40
Minimum breaking force Fmin 1770 [kN] 1189
Minimum breaking force Fmin 1960 [kN] 1316
  • Details
    Nominal rope Ø [mm] 40
    Weight approx. 745 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1189
    Minimum breaking force Fmin 1960 [kN] 1316
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
Other rope diameters and constructions on enquiry.
Downloads
Contact
Market Contact Location type
All other markets
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-301
Fax +49 8331 937-123
E-Mail wireropes@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Germany
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-181
Fax +49 8331 937-123
E-Mail seile@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Oktjaborskaja Nabereschnaja, No. 104, Korpus 23
RU-193079 St. Petersburg
Tel. +7 812 740 12-24
Fax +7 812 493 48-21
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Service centre
USA
PFEIFER Wire Rope & Lifting Technology Inc.
2023 Humble Westfield
US-Houston, TX 77037
Tel. +1 832 827 2923
Fax +1 281 784 2903
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Service centre
Austria
PFEIFER Seil- und Hebetechnik GmbH
Harterfeldweg 2
AT-4481 Asten
Tel. +43 7224 662 24-0
Fax +43 7224 662 24-13
E-Mail info@pfeifer-austria.at
Web www.pfeifer-austria.at
Sales subsidiary
China
PFEIFER Steel Wire Rope (Shanghai) Co., Ltd.
Building 1, No. 366 Chen Xiang Road, Nanxiang Town, Jiading District
CN-Shanghai 201802
Industrieseile/Industry ropes
Tel. +86 21 56 77 80 06
Fax +86 21 56 77 92 29
E-Mail info@pfeifer.com.cn
Web www.pfeifer.com.cn
Sales subsidiary
Great Britain
PFEIFER Rope & Tackle Ltd.
Unit 1A1, Marchwood Industrial Park, North Road
GB-Southampton SO40 4BL
Tel. +44 23 8066-5470
Fax +44 23 8066-5471
E-Mail sales@ropeandtackle.com
Web www.pfeifer-rt.com
Sales subsidiary
Hungary
PFEIFER Garant Kft.
Gyömrői út 108-126
HU-1103 Budapest
Tel. +36 1 260 10 14
Fax +36 1 262 09 27
E-Mail info@pfeifer-garant.hu
Web www.pfeifer-garant.hu
Sales subsidiary
Luxemburg
PFEIFER SOGEQUIP S.à.r.l.
Zone Ind. Schifflange-Foetz
LU-3844 Schifflange
Tel. +352 57 42-42
Fax +352 57 42-62
E-Mail info@pfeifer-sogequip.lu
Web www.pfeifer-sogequip.lu
Sales subsidiary
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Pyzhevskiy pereulok, h. 5, bld.1, office 108
RU-119017 Moskau
Tel. +7 495 363 01-27
Fax +7 495 363 01-28
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Sales subsidiary
Spain
PFEIFER Cables y Equipos de Elevación S.L.
Avda. de los Pirineos, 25 – Nave 20, San Sebastián de los Reyes
ES-28703 Madrid
Tel. +34 91 659-3185
Fax +34 91 659-3139
E-Mail p-es@pfeifer.es
Web www.pfeifer.es
Sales subsidiary
USA
PFEIFER Wire Rope & Lifting Technology Inc.
600 Industry Drive
US-Hampton, VA 23661
Tel. +1 757 825 2544
Fax +1 757 825 2546
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Sales subsidiary
United Arab Emirates
PFEIFER Middle East Wire Rope & Lifting Technology FZE
Jebel Ali Free Zone 1, RA08UA07, PO Box 263081
AE-Dubai
Tel. +971 4 883-8445
Fax +971 4 883-8446
E-Mail sales@pfeifer.ae
Web rope-lifting-ae.pfeifer.info
Sales subsidiary
Germany
PFEIFER Seil- und Hebetechnik GmbH
Krönenbarg 92b
DE-21077 Hamburg
Tel. +49 40 78 04 63-0
Fax +49 40 78 70 13
E-Mail psh-hamburg@pfeifer.de
Web www.pfeifer.info
Office
Switzerland
pewag Suisse AG
Hasentalstrasse 8
CH-8934 Knonau
Tel. +41 44 768 55-55
Fax +41 44 768 55-30
E-Mail info@pewag-suisse.ch
Web www.pewag-suisse.ch
Agency

Feel free to contact us

Tel.

+49 8331 937-301

Inquiry

please leave empty!
* Required fields

Cookie settings

We use cookies to optimise our web page for you. By continuing to use the web page you agree to the use of cookies. Further information about cookies can be found in our data protection declaration.

Required cookies

Required cookies are mandatory for the basic functions of the website. Without these cookies, you will unfortunately not be able to use our website. These cookies are always set when you use the website. No personal data is collected or stored.

Functional cookies

These cookies allow us to analyze website usage so that we can measure and improve its performance. No personal data is collected or stored.

Data protection declaration