P 106

P 106
technical infos

Average fill factor

  • 0.7145

average spinning loss factor 1770

  • 0.835

average spinning loss factor 1960

  • 0.835

average spinning loss factor 2160

  • 0.815

Core

  • steel core

Lay type

  • lang lay

Lay direction

  • choice of right hand or left hand

Compacting

  • strands compacted – thereby extra wear resistant

Finish

  • bright

Rope diameter tolerance

  • 0/+4%

Indication

  • Please refer to our operating manual stranded ropes! Available at www.pfeifer.info/manual-strand-ropes

  • Sample schematic of rope construction used for representative purposes only. Actual construction dependent upon rope diameter.
Product variants
Nominal rope Ø [mm]
Minimum breaking force Fmin 1770 [kN]
Minimum breaking force Fmin 1960 [kN]
Minimum breaking force Fmin 2160 [kN]
Details
  • 4
    13.3
    14.7
    15.8
    Nominal rope Ø [mm] 4
    Weight approx. 8 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 13.3
    Minimum breaking force Fmin 1960 [kN] 14.7
    Minimum breaking force Fmin 2160 [kN] 15.8
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 5
    20.7
    23
    24.7
    Nominal rope Ø [mm] 5
    Weight approx. 12 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 20.7
    Minimum breaking force Fmin 1960 [kN] 23
    Minimum breaking force Fmin 2160 [kN] 24.7
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 6
    29.9
    33.1
    35.6
    Nominal rope Ø [mm] 6
    Weight approx. 17 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 29.9
    Minimum breaking force Fmin 1960 [kN] 33.1
    Minimum breaking force Fmin 2160 [kN] 35.6
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 7
    40.6
    45
    48.4
    Nominal rope Ø [mm] 7
    Weight approx. 24 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 40.6
    Minimum breaking force Fmin 1960 [kN] 45
    Minimum breaking force Fmin 2160 [kN] 48.4
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 8
    53.1
    58.8
    63.2
    Nominal rope Ø [mm] 8
    Weight approx. 31 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 53.1
    Minimum breaking force Fmin 1960 [kN] 58.8
    Minimum breaking force Fmin 2160 [kN] 63.2
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 9
    67.2
    74.4
    80
    Nominal rope Ø [mm] 9
    Weight approx. 39 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 67.2
    Minimum breaking force Fmin 1960 [kN] 74.4
    Minimum breaking force Fmin 2160 [kN] 80
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 10
    82.4
    91.7
    98.6
    Nominal rope Ø [mm] 10
    Weight approx. 49 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 82.4
    Minimum breaking force Fmin 1960 [kN] 91.7
    Minimum breaking force Fmin 2160 [kN] 98.6
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 11
    101
    112
    120
    Nominal rope Ø [mm] 11
    Weight approx. 59 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 101
    Minimum breaking force Fmin 1960 [kN] 112
    Minimum breaking force Fmin 2160 [kN] 120
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 12
    119
    132
    142
    Nominal rope Ø [mm] 12
    Weight approx. 70 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 119
    Minimum breaking force Fmin 1960 [kN] 132
    Minimum breaking force Fmin 2160 [kN] 142
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 13
    141
    156
    168
    Nominal rope Ø [mm] 13
    Weight approx. 83 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 141
    Minimum breaking force Fmin 1960 [kN] 156
    Minimum breaking force Fmin 2160 [kN] 168
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 14
    162
    181
    194
    Nominal rope Ø [mm] 14
    Weight approx. 95 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 162
    Minimum breaking force Fmin 1960 [kN] 181
    Minimum breaking force Fmin 2160 [kN] 194
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 15
    186
    207
    222
    Nominal rope Ø [mm] 15
    Weight approx. 109 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 186
    Minimum breaking force Fmin 1960 [kN] 207
    Minimum breaking force Fmin 2160 [kN] 222
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 16
    214
    238
    256
    Nominal rope Ø [mm] 16
    Weight approx. 126 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 214
    Minimum breaking force Fmin 1960 [kN] 238
    Minimum breaking force Fmin 2160 [kN] 256
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 17
    240
    267
    287
    Nominal rope Ø [mm] 17
    Weight approx. 141 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 240
    Minimum breaking force Fmin 1960 [kN] 267
    Minimum breaking force Fmin 2160 [kN] 287
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 18
    271
    301
    323
    Nominal rope Ø [mm] 18
    Weight approx. 159 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 271
    Minimum breaking force Fmin 1960 [kN] 301
    Minimum breaking force Fmin 2160 [kN] 323
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 19
    300
    333
    358
    Nominal rope Ø [mm] 19
    Weight approx. 176 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 300
    Minimum breaking force Fmin 1960 [kN] 333
    Minimum breaking force Fmin 2160 [kN] 358
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 20
    334
    371
    398
    Nominal rope Ø [mm] 20
    Weight approx. 196 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 334
    Minimum breaking force Fmin 1960 [kN] 371
    Minimum breaking force Fmin 2160 [kN] 398
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 21
    371
    412
    442
    Nominal rope Ø [mm] 21
    Weight approx. 218 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 371
    Minimum breaking force Fmin 1960 [kN] 412
    Minimum breaking force Fmin 2160 [kN] 442
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 22
    406
    451
    485
    Nominal rope Ø [mm] 22
    Weight approx. 238 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 406
    Minimum breaking force Fmin 1960 [kN] 451
    Minimum breaking force Fmin 2160 [kN] 485
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 23
    442
    491
    528
    Nominal rope Ø [mm] 23
    Weight approx. 260 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 442
    Minimum breaking force Fmin 1960 [kN] 491
    Minimum breaking force Fmin 2160 [kN] 528
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 24
    481
    534
    573
    Nominal rope Ø [mm] 24
    Weight approx. 282 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 481
    Minimum breaking force Fmin 1960 [kN] 534
    Minimum breaking force Fmin 2160 [kN] 573
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 25
    512
    569
    611
    Nominal rope Ø [mm] 25
    Weight approx. 301 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 512
    Minimum breaking force Fmin 1960 [kN] 569
    Minimum breaking force Fmin 2160 [kN] 611
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 26
    554
    616
    661
    Nominal rope Ø [mm] 26
    Weight approx. 325 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 554
    Minimum breaking force Fmin 1960 [kN] 616
    Minimum breaking force Fmin 2160 [kN] 661
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 27
    596
    662
    711
    Nominal rope Ø [mm] 27
    Weight approx. 350 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 596
    Minimum breaking force Fmin 1960 [kN] 662
    Minimum breaking force Fmin 2160 [kN] 711
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 28
    652
    725
    778
    Nominal rope Ø [mm] 28
    Weight approx. 383 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 652
    Minimum breaking force Fmin 1960 [kN] 725
    Minimum breaking force Fmin 2160 [kN] 778
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 29
    692
    769
    825
    Nominal rope Ø [mm] 29
    Weight approx. 406 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 692
    Minimum breaking force Fmin 1960 [kN] 769
    Minimum breaking force Fmin 2160 [kN] 825
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 30
    740
    822
    883
    Nominal rope Ø [mm] 30
    Weight approx. 434 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 740
    Minimum breaking force Fmin 1960 [kN] 822
    Minimum breaking force Fmin 2160 [kN] 883
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 31
    786
    874
    938
    Nominal rope Ø [mm] 31
    Weight approx. 461 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 786
    Minimum breaking force Fmin 1960 [kN] 874
    Minimum breaking force Fmin 2160 [kN] 938
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 32
    844
    937
    1006
    Nominal rope Ø [mm] 32
    Weight approx. 495 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 844
    Minimum breaking force Fmin 1960 [kN] 937
    Minimum breaking force Fmin 2160 [kN] 1006
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 33
    895
    995
    1068
    Nominal rope Ø [mm] 33
    Weight approx. 525 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 895
    Minimum breaking force Fmin 1960 [kN] 995
    Minimum breaking force Fmin 2160 [kN] 1068
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 34
    952
    1058
    1136
    Nominal rope Ø [mm] 34
    Weight approx. 559 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 952
    Minimum breaking force Fmin 1960 [kN] 1058
    Minimum breaking force Fmin 2160 [kN] 1136
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 35
    1013
    1126
    1209
    Nominal rope Ø [mm] 35
    Weight approx. 595 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1013
    Minimum breaking force Fmin 1960 [kN] 1126
    Minimum breaking force Fmin 2160 [kN] 1209
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 36
    1072
    1191
    1279
    Nominal rope Ø [mm] 36
    Weight approx. 629 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1072
    Minimum breaking force Fmin 1960 [kN] 1191
    Minimum breaking force Fmin 2160 [kN] 1279
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 37
    1132
    1258
    1351
    Nominal rope Ø [mm] 37
    Weight approx. 665 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1132
    Minimum breaking force Fmin 1960 [kN] 1258
    Minimum breaking force Fmin 2160 [kN] 1351
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 38
    1194
    1327
    1425
    Nominal rope Ø [mm] 38
    Weight approx. 701 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1194
    Minimum breaking force Fmin 1960 [kN] 1327
    Minimum breaking force Fmin 2160 [kN] 1425
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 39
    1258
    1398
    1501
    Nominal rope Ø [mm] 39
    Weight approx. 738 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1258
    Minimum breaking force Fmin 1960 [kN] 1398
    Minimum breaking force Fmin 2160 [kN] 1501
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 40
    1323
    1471
    1579
    Nominal rope Ø [mm] 40
    Weight approx. 777 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1323
    Minimum breaking force Fmin 1960 [kN] 1471
    Minimum breaking force Fmin 2160 [kN] 1579
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 41
    1390
    1545
    1659
    Nominal rope Ø [mm] 41
    Weight approx. 816 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1390
    Minimum breaking force Fmin 1960 [kN] 1545
    Minimum breaking force Fmin 2160 [kN] 1659
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 42
    1459
    1621
    1741
    Nominal rope Ø [mm] 42
    Weight approx. 856 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1459
    Minimum breaking force Fmin 1960 [kN] 1621
    Minimum breaking force Fmin 2160 [kN] 1741
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 43
    1529
    1700
    1825
    Nominal rope Ø [mm] 43
    Weight approx. 898 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1529
    Minimum breaking force Fmin 1960 [kN] 1700
    Minimum breaking force Fmin 2160 [kN] 1825
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 44
    1601
    1780
    1910
    Nominal rope Ø [mm] 44
    Weight approx. 940 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1601
    Minimum breaking force Fmin 1960 [kN] 1780
    Minimum breaking force Fmin 2160 [kN] 1910
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 45
    1675
    1861
    1999
    Nominal rope Ø [mm] 45
    Weight approx. 983 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1675
    Minimum breaking force Fmin 1960 [kN] 1861
    Minimum breaking force Fmin 2160 [kN] 1999
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 46
    1750
    1945
    2088
    Nominal rope Ø [mm] 46
    Weight approx. 1027 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1750
    Minimum breaking force Fmin 1960 [kN] 1945
    Minimum breaking force Fmin 2160 [kN] 2088
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 47
    1827
    2030
    2180
    Nominal rope Ø [mm] 47
    Weight approx. 1072 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1827
    Minimum breaking force Fmin 1960 [kN] 2030
    Minimum breaking force Fmin 2160 [kN] 2180
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 48
    1906
    2117
    2273
    Nominal rope Ø [mm] 48
    Weight approx. 1118 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1906
    Minimum breaking force Fmin 1960 [kN] 2117
    Minimum breaking force Fmin 2160 [kN] 2273
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 49
    1986
    2207
    2370
    Nominal rope Ø [mm] 49
    Weight approx. 1165 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1986
    Minimum breaking force Fmin 1960 [kN] 2207
    Minimum breaking force Fmin 2160 [kN] 2370
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 50
    2068
    2298
    2467
    Nominal rope Ø [mm] 50
    Weight approx. 1214 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2068
    Minimum breaking force Fmin 1960 [kN] 2298
    Minimum breaking force Fmin 2160 [kN] 2467
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 51
    2152
    2391
    2567
    Nominal rope Ø [mm] 51
    Weight approx. 1263 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2152
    Minimum breaking force Fmin 1960 [kN] 2391
    Minimum breaking force Fmin 2160 [kN] 2567
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 52
    2237
    2485
    2668
    Nominal rope Ø [mm] 52
    Weight approx. 1313 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2237
    Minimum breaking force Fmin 1960 [kN] 2485
    Minimum breaking force Fmin 2160 [kN] 2668
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 53
    2323
    2582
    2772
    Nominal rope Ø [mm] 53
    Weight approx. 1364 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2323
    Minimum breaking force Fmin 1960 [kN] 2582
    Minimum breaking force Fmin 2160 [kN] 2772
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 54
    2412
    2681
    2878
    Nominal rope Ø [mm] 54
    Weight approx. 1415 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2412
    Minimum breaking force Fmin 1960 [kN] 2681
    Minimum breaking force Fmin 2160 [kN] 2878
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 55
    2503
    2781
    2986
    Nominal rope Ø [mm] 55
    Weight approx. 1468 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2503
    Minimum breaking force Fmin 1960 [kN] 2781
    Minimum breaking force Fmin 2160 [kN] 2986
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 56
    2594
    2883
    3095
    Nominal rope Ø [mm] 56
    Weight approx. 1522 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2594
    Minimum breaking force Fmin 1960 [kN] 2883
    Minimum breaking force Fmin 2160 [kN] 3095
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 57
    2695
    2984
    3209
    Nominal rope Ø [mm] 57
    Weight approx. 1577 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2695
    Minimum breaking force Fmin 1960 [kN] 2984
    Minimum breaking force Fmin 2160 [kN] 3209
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 58
    2790
    3090
    3324
    Nominal rope Ø [mm] 58
    Weight approx. 1633 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2790
    Minimum breaking force Fmin 1960 [kN] 3090
    Minimum breaking force Fmin 2160 [kN] 3324
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 59
    2887
    3197
    3438
    Nominal rope Ø [mm] 59
    Weight approx. 1690 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2887
    Minimum breaking force Fmin 1960 [kN] 3197
    Minimum breaking force Fmin 2160 [kN] 3438
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 60
    2986
    3307
    3557
    Nominal rope Ø [mm] 60
    Weight approx. 1747 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2986
    Minimum breaking force Fmin 1960 [kN] 3307
    Minimum breaking force Fmin 2160 [kN] 3557
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 61
    3086
    3418
    3676
    Nominal rope Ø [mm] 61
    Weight approx. 1806 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3086
    Minimum breaking force Fmin 1960 [kN] 3418
    Minimum breaking force Fmin 2160 [kN] 3676
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 62
    3188
    3530
    3797
    Nominal rope Ø [mm] 62
    Weight approx. 1866 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3188
    Minimum breaking force Fmin 1960 [kN] 3530
    Minimum breaking force Fmin 2160 [kN] 3797
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 63
    3292
    3645
    3921
    Nominal rope Ø [mm] 63
    Weight approx. 1927 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3292
    Minimum breaking force Fmin 1960 [kN] 3645
    Minimum breaking force Fmin 2160 [kN] 3921
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 64
    3397
    3762
    4046
    Nominal rope Ø [mm] 64
    Weight approx. 1988 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3397
    Minimum breaking force Fmin 1960 [kN] 3762
    Minimum breaking force Fmin 2160 [kN] 4046
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 65
    3504
    3880
    4174
    Nominal rope Ø [mm] 65
    Weight approx. 2051 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3504
    Minimum breaking force Fmin 1960 [kN] 3880
    Minimum breaking force Fmin 2160 [kN] 4174
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 66
    3613
    4000
    4303
    Nominal rope Ø [mm] 66
    Weight approx. 2114 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3613
    Minimum breaking force Fmin 1960 [kN] 4000
    Minimum breaking force Fmin 2160 [kN] 4303
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 67
    3723
    4122
    4434
    Nominal rope Ø [mm] 67
    Weight approx. 2179 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3723
    Minimum breaking force Fmin 1960 [kN] 4122
    Minimum breaking force Fmin 2160 [kN] 4434
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 68
    3835
    4247
    4568
    Nominal rope Ø [mm] 68
    Weight approx. 2245 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3835
    Minimum breaking force Fmin 1960 [kN] 4247
    Minimum breaking force Fmin 2160 [kN] 4568
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 69
    3949
    4373
    4703
    Nominal rope Ø [mm] 69
    Weight approx. 2311 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3949
    Minimum breaking force Fmin 1960 [kN] 4373
    Minimum breaking force Fmin 2160 [kN] 4703
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 70
    4064
    4500
    4840
    Nominal rope Ø [mm] 70
    Weight approx. 2379 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4064
    Minimum breaking force Fmin 1960 [kN] 4500
    Minimum breaking force Fmin 2160 [kN] 4840
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 71
    4181
    4630
    Nominal rope Ø [mm] 71
    Weight approx. 2447 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4181
    Minimum breaking force Fmin 1960 [kN] 4630
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 72
    4299
    4761
    Nominal rope Ø [mm] 72
    Weight approx. 2516 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4299
    Minimum breaking force Fmin 1960 [kN] 4761
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 73
    4420
    4894
    Nominal rope Ø [mm] 73
    Weight approx. 2587 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4420
    Minimum breaking force Fmin 1960 [kN] 4894
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 74
    4542
    5029
    Nominal rope Ø [mm] 74
    Weight approx. 2658 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4542
    Minimum breaking force Fmin 1960 [kN] 5029
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 75
    4665
    5166
    Nominal rope Ø [mm] 75
    Weight approx. 2730 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4665
    Minimum breaking force Fmin 1960 [kN] 5166
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 76
    4790
    5305
    Nominal rope Ø [mm] 76
    Weight approx. 2804 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4790
    Minimum breaking force Fmin 1960 [kN] 5305
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 77
    4917
    5445
    Nominal rope Ø [mm] 77
    Weight approx. 2878 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4917
    Minimum breaking force Fmin 1960 [kN] 5445
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 78
    5046
    5588
    Nominal rope Ø [mm] 78
    Weight approx. 2953 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5046
    Minimum breaking force Fmin 1960 [kN] 5588
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 79
    5176
    5731
    Nominal rope Ø [mm] 79
    Weight approx. 3029 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5176
    Minimum breaking force Fmin 1960 [kN] 5731
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 80
    5308
    5878
    Nominal rope Ø [mm] 80
    Weight approx. 3107 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5308
    Minimum breaking force Fmin 1960 [kN] 5878
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 81
    5442
    6025
    Nominal rope Ø [mm] 81
    Weight approx. 3185 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5442
    Minimum breaking force Fmin 1960 [kN] 6025
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 82
    5577
    6176
    Nominal rope Ø [mm] 82
    Weight approx. 3264 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5577
    Minimum breaking force Fmin 1960 [kN] 6176
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 83
    5714
    6327
    Nominal rope Ø [mm] 83
    Weight approx. 3344 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5714
    Minimum breaking force Fmin 1960 [kN] 6327
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 84
    5852
    6480
    Nominal rope Ø [mm] 84
    Weight approx. 3425 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5852
    Minimum breaking force Fmin 1960 [kN] 6480
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 85
    5992
    6636
    Nominal rope Ø [mm] 85
    Weight approx. 3507 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5992
    Minimum breaking force Fmin 1960 [kN] 6636
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 86
    6134
    6793
    Nominal rope Ø [mm] 86
    Weight approx. 3590 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 6134
    Minimum breaking force Fmin 1960 [kN] 6793
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 87
    6278
    6951
    Nominal rope Ø [mm] 87
    Weight approx. 3674 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 6278
    Minimum breaking force Fmin 1960 [kN] 6951
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 88
    6423
    7113
    Nominal rope Ø [mm] 88
    Weight approx. 3759 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 6423
    Minimum breaking force Fmin 1960 [kN] 7113
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 89
    6570
    7275
    Nominal rope Ø [mm] 89
    Weight approx. 3845 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 6570
    Minimum breaking force Fmin 1960 [kN] 7275
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 90
    6718
    7439
    Nominal rope Ø [mm] 90
    Weight approx. 3932 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 6718
    Minimum breaking force Fmin 1960 [kN] 7439
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 91
    6868
    7605
    Nominal rope Ø [mm] 91
    Weight approx. 4020 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 6868
    Minimum breaking force Fmin 1960 [kN] 7605
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 92
    7020
    7773
    Nominal rope Ø [mm] 92
    Weight approx. 4109 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7020
    Minimum breaking force Fmin 1960 [kN] 7773
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 93
    7173
    7943
    Nominal rope Ø [mm] 93
    Weight approx. 4198 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7173
    Minimum breaking force Fmin 1960 [kN] 7943
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 94
    7329
    8115
    Nominal rope Ø [mm] 94
    Weight approx. 4289 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7329
    Minimum breaking force Fmin 1960 [kN] 8115
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 95
    7485
    8289
    Nominal rope Ø [mm] 95
    Weight approx. 4381 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7485
    Minimum breaking force Fmin 1960 [kN] 8289
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 96
    7644
    8464
    Nominal rope Ø [mm] 96
    Weight approx. 4474 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7644
    Minimum breaking force Fmin 1960 [kN] 8464
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 97
    7804
    8641
    Nominal rope Ø [mm] 97
    Weight approx. 4567 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7804
    Minimum breaking force Fmin 1960 [kN] 8641
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 98
    7965
    8820
    Nominal rope Ø [mm] 98
    Weight approx. 4662 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7965
    Minimum breaking force Fmin 1960 [kN] 8820
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 99
    8129
    9001
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 4
Minimum breaking force Fmin 1770 [kN] 13.3
Minimum breaking force Fmin 1960 [kN] 14.7
Minimum breaking force Fmin 2160 [kN] 15.8
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 5
Minimum breaking force Fmin 1770 [kN] 20.7
Minimum breaking force Fmin 1960 [kN] 23
Minimum breaking force Fmin 2160 [kN] 24.7
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 6
Minimum breaking force Fmin 1770 [kN] 29.9
Minimum breaking force Fmin 1960 [kN] 33.1
Minimum breaking force Fmin 2160 [kN] 35.6
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 7
Minimum breaking force Fmin 1770 [kN] 40.6
Minimum breaking force Fmin 1960 [kN] 45
Minimum breaking force Fmin 2160 [kN] 48.4
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 8
Minimum breaking force Fmin 1770 [kN] 53.1
Minimum breaking force Fmin 1960 [kN] 58.8
Minimum breaking force Fmin 2160 [kN] 63.2
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 9
Minimum breaking force Fmin 1770 [kN] 67.2
Minimum breaking force Fmin 1960 [kN] 74.4
Minimum breaking force Fmin 2160 [kN] 80
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 10
Minimum breaking force Fmin 1770 [kN] 82.4
Minimum breaking force Fmin 1960 [kN] 91.7
Minimum breaking force Fmin 2160 [kN] 98.6
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 11
Minimum breaking force Fmin 1770 [kN] 101
Minimum breaking force Fmin 1960 [kN] 112
Minimum breaking force Fmin 2160 [kN] 120
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 12
Minimum breaking force Fmin 1770 [kN] 119
Minimum breaking force Fmin 1960 [kN] 132
Minimum breaking force Fmin 2160 [kN] 142
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 13
Minimum breaking force Fmin 1770 [kN] 141
Minimum breaking force Fmin 1960 [kN] 156
Minimum breaking force Fmin 2160 [kN] 168
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 14
Minimum breaking force Fmin 1770 [kN] 162
Minimum breaking force Fmin 1960 [kN] 181
Minimum breaking force Fmin 2160 [kN] 194
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 15
Minimum breaking force Fmin 1770 [kN] 186
Minimum breaking force Fmin 1960 [kN] 207
Minimum breaking force Fmin 2160 [kN] 222
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 16
Minimum breaking force Fmin 1770 [kN] 214
Minimum breaking force Fmin 1960 [kN] 238
Minimum breaking force Fmin 2160 [kN] 256
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 17
Minimum breaking force Fmin 1770 [kN] 240
Minimum breaking force Fmin 1960 [kN] 267
Minimum breaking force Fmin 2160 [kN] 287
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 18
Minimum breaking force Fmin 1770 [kN] 271
Minimum breaking force Fmin 1960 [kN] 301
Minimum breaking force Fmin 2160 [kN] 323
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 19
Minimum breaking force Fmin 1770 [kN] 300
Minimum breaking force Fmin 1960 [kN] 333
Minimum breaking force Fmin 2160 [kN] 358
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 20
Minimum breaking force Fmin 1770 [kN] 334
Minimum breaking force Fmin 1960 [kN] 371
Minimum breaking force Fmin 2160 [kN] 398
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 21
Minimum breaking force Fmin 1770 [kN] 371
Minimum breaking force Fmin 1960 [kN] 412
Minimum breaking force Fmin 2160 [kN] 442
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 22
Minimum breaking force Fmin 1770 [kN] 406
Minimum breaking force Fmin 1960 [kN] 451
Minimum breaking force Fmin 2160 [kN] 485
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 23
Minimum breaking force Fmin 1770 [kN] 442
Minimum breaking force Fmin 1960 [kN] 491
Minimum breaking force Fmin 2160 [kN] 528
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 24
Minimum breaking force Fmin 1770 [kN] 481
Minimum breaking force Fmin 1960 [kN] 534
Minimum breaking force Fmin 2160 [kN] 573
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 25
Minimum breaking force Fmin 1770 [kN] 512
Minimum breaking force Fmin 1960 [kN] 569
Minimum breaking force Fmin 2160 [kN] 611
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 26
Minimum breaking force Fmin 1770 [kN] 554
Minimum breaking force Fmin 1960 [kN] 616
Minimum breaking force Fmin 2160 [kN] 661
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 27
Minimum breaking force Fmin 1770 [kN] 596
Minimum breaking force Fmin 1960 [kN] 662
Minimum breaking force Fmin 2160 [kN] 711
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 28
Minimum breaking force Fmin 1770 [kN] 652
Minimum breaking force Fmin 1960 [kN] 725
Minimum breaking force Fmin 2160 [kN] 778
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 29
Minimum breaking force Fmin 1770 [kN] 692
Minimum breaking force Fmin 1960 [kN] 769
Minimum breaking force Fmin 2160 [kN] 825
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 30
Minimum breaking force Fmin 1770 [kN] 740
Minimum breaking force Fmin 1960 [kN] 822
Minimum breaking force Fmin 2160 [kN] 883
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 31
Minimum breaking force Fmin 1770 [kN] 786
Minimum breaking force Fmin 1960 [kN] 874
Minimum breaking force Fmin 2160 [kN] 938
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 32
Minimum breaking force Fmin 1770 [kN] 844
Minimum breaking force Fmin 1960 [kN] 937
Minimum breaking force Fmin 2160 [kN] 1006
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 33
Minimum breaking force Fmin 1770 [kN] 895
Minimum breaking force Fmin 1960 [kN] 995
Minimum breaking force Fmin 2160 [kN] 1068
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 34
Minimum breaking force Fmin 1770 [kN] 952
Minimum breaking force Fmin 1960 [kN] 1058
Minimum breaking force Fmin 2160 [kN] 1136
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 35
Minimum breaking force Fmin 1770 [kN] 1013
Minimum breaking force Fmin 1960 [kN] 1126
Minimum breaking force Fmin 2160 [kN] 1209
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 36
Minimum breaking force Fmin 1770 [kN] 1072
Minimum breaking force Fmin 1960 [kN] 1191
Minimum breaking force Fmin 2160 [kN] 1279
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 37
Minimum breaking force Fmin 1770 [kN] 1132
Minimum breaking force Fmin 1960 [kN] 1258
Minimum breaking force Fmin 2160 [kN] 1351
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 38
Minimum breaking force Fmin 1770 [kN] 1194
Minimum breaking force Fmin 1960 [kN] 1327
Minimum breaking force Fmin 2160 [kN] 1425
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 39
Minimum breaking force Fmin 1770 [kN] 1258
Minimum breaking force Fmin 1960 [kN] 1398
Minimum breaking force Fmin 2160 [kN] 1501
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 40
Minimum breaking force Fmin 1770 [kN] 1323
Minimum breaking force Fmin 1960 [kN] 1471
Minimum breaking force Fmin 2160 [kN] 1579
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 41
Minimum breaking force Fmin 1770 [kN] 1390
Minimum breaking force Fmin 1960 [kN] 1545
Minimum breaking force Fmin 2160 [kN] 1659
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 42
Minimum breaking force Fmin 1770 [kN] 1459
Minimum breaking force Fmin 1960 [kN] 1621
Minimum breaking force Fmin 2160 [kN] 1741
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 43
Minimum breaking force Fmin 1770 [kN] 1529
Minimum breaking force Fmin 1960 [kN] 1700
Minimum breaking force Fmin 2160 [kN] 1825
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 44
Minimum breaking force Fmin 1770 [kN] 1601
Minimum breaking force Fmin 1960 [kN] 1780
Minimum breaking force Fmin 2160 [kN] 1910
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 45
Minimum breaking force Fmin 1770 [kN] 1675
Minimum breaking force Fmin 1960 [kN] 1861
Minimum breaking force Fmin 2160 [kN] 1999
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 46
Minimum breaking force Fmin 1770 [kN] 1750
Minimum breaking force Fmin 1960 [kN] 1945
Minimum breaking force Fmin 2160 [kN] 2088
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 47
Minimum breaking force Fmin 1770 [kN] 1827
Minimum breaking force Fmin 1960 [kN] 2030
Minimum breaking force Fmin 2160 [kN] 2180
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 48
Minimum breaking force Fmin 1770 [kN] 1906
Minimum breaking force Fmin 1960 [kN] 2117
Minimum breaking force Fmin 2160 [kN] 2273
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 49
Minimum breaking force Fmin 1770 [kN] 1986
Minimum breaking force Fmin 1960 [kN] 2207
Minimum breaking force Fmin 2160 [kN] 2370
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 50
Minimum breaking force Fmin 1770 [kN] 2068
Minimum breaking force Fmin 1960 [kN] 2298
Minimum breaking force Fmin 2160 [kN] 2467
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 51
Minimum breaking force Fmin 1770 [kN] 2152
Minimum breaking force Fmin 1960 [kN] 2391
Minimum breaking force Fmin 2160 [kN] 2567
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 52
Minimum breaking force Fmin 1770 [kN] 2237
Minimum breaking force Fmin 1960 [kN] 2485
Minimum breaking force Fmin 2160 [kN] 2668
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 53
Minimum breaking force Fmin 1770 [kN] 2323
Minimum breaking force Fmin 1960 [kN] 2582
Minimum breaking force Fmin 2160 [kN] 2772
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 54
Minimum breaking force Fmin 1770 [kN] 2412
Minimum breaking force Fmin 1960 [kN] 2681
Minimum breaking force Fmin 2160 [kN] 2878
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 55
Minimum breaking force Fmin 1770 [kN] 2503
Minimum breaking force Fmin 1960 [kN] 2781
Minimum breaking force Fmin 2160 [kN] 2986
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 56
Minimum breaking force Fmin 1770 [kN] 2594
Minimum breaking force Fmin 1960 [kN] 2883
Minimum breaking force Fmin 2160 [kN] 3095
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 57
Minimum breaking force Fmin 1770 [kN] 2695
Minimum breaking force Fmin 1960 [kN] 2984
Minimum breaking force Fmin 2160 [kN] 3209
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 58
Minimum breaking force Fmin 1770 [kN] 2790
Minimum breaking force Fmin 1960 [kN] 3090
Minimum breaking force Fmin 2160 [kN] 3324
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 59
Minimum breaking force Fmin 1770 [kN] 2887
Minimum breaking force Fmin 1960 [kN] 3197
Minimum breaking force Fmin 2160 [kN] 3438
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 60
Minimum breaking force Fmin 1770 [kN] 2986
Minimum breaking force Fmin 1960 [kN] 3307
Minimum breaking force Fmin 2160 [kN] 3557
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 61
Minimum breaking force Fmin 1770 [kN] 3086
Minimum breaking force Fmin 1960 [kN] 3418
Minimum breaking force Fmin 2160 [kN] 3676
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 62
Minimum breaking force Fmin 1770 [kN] 3188
Minimum breaking force Fmin 1960 [kN] 3530
Minimum breaking force Fmin 2160 [kN] 3797
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 63
Minimum breaking force Fmin 1770 [kN] 3292
Minimum breaking force Fmin 1960 [kN] 3645
Minimum breaking force Fmin 2160 [kN] 3921
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 64
Minimum breaking force Fmin 1770 [kN] 3397
Minimum breaking force Fmin 1960 [kN] 3762
Minimum breaking force Fmin 2160 [kN] 4046
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 65
Minimum breaking force Fmin 1770 [kN] 3504
Minimum breaking force Fmin 1960 [kN] 3880
Minimum breaking force Fmin 2160 [kN] 4174
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 66
Minimum breaking force Fmin 1770 [kN] 3613
Minimum breaking force Fmin 1960 [kN] 4000
Minimum breaking force Fmin 2160 [kN] 4303
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 67
Minimum breaking force Fmin 1770 [kN] 3723
Minimum breaking force Fmin 1960 [kN] 4122
Minimum breaking force Fmin 2160 [kN] 4434
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 68
Minimum breaking force Fmin 1770 [kN] 3835
Minimum breaking force Fmin 1960 [kN] 4247
Minimum breaking force Fmin 2160 [kN] 4568
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 69
Minimum breaking force Fmin 1770 [kN] 3949
Minimum breaking force Fmin 1960 [kN] 4373
Minimum breaking force Fmin 2160 [kN] 4703
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 70
Minimum breaking force Fmin 1770 [kN] 4064
Minimum breaking force Fmin 1960 [kN] 4500
Minimum breaking force Fmin 2160 [kN] 4840
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 71
Minimum breaking force Fmin 1770 [kN] 4181
Minimum breaking force Fmin 1960 [kN] 4630
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 72
Minimum breaking force Fmin 1770 [kN] 4299
Minimum breaking force Fmin 1960 [kN] 4761
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 73
Minimum breaking force Fmin 1770 [kN] 4420
Minimum breaking force Fmin 1960 [kN] 4894
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 74
Minimum breaking force Fmin 1770 [kN] 4542
Minimum breaking force Fmin 1960 [kN] 5029
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 75
Minimum breaking force Fmin 1770 [kN] 4665
Minimum breaking force Fmin 1960 [kN] 5166
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 76
Minimum breaking force Fmin 1770 [kN] 4790
Minimum breaking force Fmin 1960 [kN] 5305
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 77
Minimum breaking force Fmin 1770 [kN] 4917
Minimum breaking force Fmin 1960 [kN] 5445
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 78
Minimum breaking force Fmin 1770 [kN] 5046
Minimum breaking force Fmin 1960 [kN] 5588
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 79
Minimum breaking force Fmin 1770 [kN] 5176
Minimum breaking force Fmin 1960 [kN] 5731
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 80
Minimum breaking force Fmin 1770 [kN] 5308
Minimum breaking force Fmin 1960 [kN] 5878
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 81
Minimum breaking force Fmin 1770 [kN] 5442
Minimum breaking force Fmin 1960 [kN] 6025
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 82
Minimum breaking force Fmin 1770 [kN] 5577
Minimum breaking force Fmin 1960 [kN] 6176
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 83
Minimum breaking force Fmin 1770 [kN] 5714
Minimum breaking force Fmin 1960 [kN] 6327
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 84
Minimum breaking force Fmin 1770 [kN] 5852
Minimum breaking force Fmin 1960 [kN] 6480
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 85
Minimum breaking force Fmin 1770 [kN] 5992
Minimum breaking force Fmin 1960 [kN] 6636
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 86
Minimum breaking force Fmin 1770 [kN] 6134
Minimum breaking force Fmin 1960 [kN] 6793
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 87
Minimum breaking force Fmin 1770 [kN] 6278
Minimum breaking force Fmin 1960 [kN] 6951
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 88
Minimum breaking force Fmin 1770 [kN] 6423
Minimum breaking force Fmin 1960 [kN] 7113
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 89
Minimum breaking force Fmin 1770 [kN] 6570
Minimum breaking force Fmin 1960 [kN] 7275
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 90
Minimum breaking force Fmin 1770 [kN] 6718
Minimum breaking force Fmin 1960 [kN] 7439
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 91
Minimum breaking force Fmin 1770 [kN] 6868
Minimum breaking force Fmin 1960 [kN] 7605
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 92
Minimum breaking force Fmin 1770 [kN] 7020
Minimum breaking force Fmin 1960 [kN] 7773
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 93
Minimum breaking force Fmin 1770 [kN] 7173
Minimum breaking force Fmin 1960 [kN] 7943
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 94
Minimum breaking force Fmin 1770 [kN] 7329
Minimum breaking force Fmin 1960 [kN] 8115
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 95
Minimum breaking force Fmin 1770 [kN] 7485
Minimum breaking force Fmin 1960 [kN] 8289
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 96
Minimum breaking force Fmin 1770 [kN] 7644
Minimum breaking force Fmin 1960 [kN] 8464
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 97
Minimum breaking force Fmin 1770 [kN] 7804
Minimum breaking force Fmin 1960 [kN] 8641
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 98
Minimum breaking force Fmin 1770 [kN] 7965
Minimum breaking force Fmin 1960 [kN] 8820
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 99
Minimum breaking force Fmin 1770 [kN] 8129
Minimum breaking force Fmin 1960 [kN] 9001
  • Details
    Nominal rope Ø [mm] 99
    Weight approx. 4758 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 8129
    Minimum breaking force Fmin 1960 [kN] 9001
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Other rope diameters and constructions on enquiry.
Downloads
Contact
Market Contact Location type
All other markets
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-301
Fax +49 8331 937-123
E-Mail wireropes@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Germany
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-181
Fax +49 8331 937-123
E-Mail seile@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Oktjaborskaja Nabereschnaja, No. 104, Korpus 23
RU-193079 St. Petersburg
Tel. +7 812 740 12-24
Fax +7 812 493 48-21
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Service centre
USA
PFEIFER Wire Rope & Lifting Technology Inc.
2023 Humble Westfield
US-Houston, TX 77037
Tel. +1 832 827 2923
Fax +1 281 784 2903
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Service centre
Austria
PFEIFER Seil- und Hebetechnik GmbH
Harterfeldweg 2
AT-4481 Asten
Tel. +43 7224 662 24-0
Fax +43 7224 662 24-13
E-Mail info@pfeifer-austria.at
Web www.pfeifer-austria.at
Sales subsidiary
China
PFEIFER Steel Wire Rope (Shanghai) Co., Ltd.
9th Floor, No. 2555 Jiayinyuan Road, Nanxiang Town, Jiading District
CN-Shanghai
Industrieseile/Industry ropes
Tel. +86 21 56 77 80 06
Fax +86 21 56 77 92 29
E-Mail info@pfeifer.com.cn
Web www.pfeifer.com.cn
Sales subsidiary
Great Britain
PFEIFER DRAKO Ltd.
Unit 1A1, Marchwood Industrial Park, North Road
GB-Southampton SO40 4BL
Tel. +44 23 8066-5470
Fax +44 23 8066-5471
E-Mail southampton@pfeifer.uk
Web www.pfeifer.co.uk
Sales subsidiary
Hungary
PFEIFER Garant Kft.
Gyömrői út 108-126
HU-1103 Budapest
Tel. +36 1 260 10 14
Fax +36 1 262 09 27
E-Mail info@pfeifer-garant.hu
Web www.pfeifer-garant.hu
Sales subsidiary
Luxemburg
PFEIFER SOGEQUIP S.à.r.l.
Zone Ind. Schifflange-Foetz
LU-3844 Schifflange
Tel. +352 57 42-42
Fax +352 57 42-62
E-Mail info@pfeifer-sogequip.lu
Web www.pfeifer-sogequip.lu
Sales subsidiary
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Pyzhevskiy pereulok, h. 5, bld.1, office 108
RU-119017 Moskau
Tel. +7 495 363 01-27
Fax +7 495 363 01-28
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Sales subsidiary
Spain
PFEIFER Cables y Equipos de Elevación S.L.
Avda. de los Pirineos, 25 – Nave 20, San Sebastián de los Reyes
ES-28703 Madrid
Tel. +34 91 659-3185
Fax +34 91 659-3139
E-Mail p-es@pfeifer.es
Web www.pfeifer.es
Sales subsidiary
USA
PFEIFER Wire Rope & Lifting Technology Inc.
600 Industry Drive
US-Hampton, VA 23661
Tel. +1 757 825 2544
Fax +1 757 825 2546
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Sales subsidiary
United Arab Emirates
PFEIFER Middle East Wire Rope & Lifting Technology FZE
Jebel Ali Free Zone 1, RA08UA07, PO Box 263081
AE-Dubai
Tel. +971 4 883-8445
Fax +971 4 883-8446
E-Mail sales@pfeifer.ae
Web rope-lifting-ae.pfeifer.info
Sales subsidiary
Germany
PFEIFER Seil- und Hebetechnik GmbH
Krönenbarg 92b
DE-21077 Hamburg
Tel. +49 40 78 04 63-0
Fax +49 40 78 70 13
E-Mail psh-hamburg@pfeifer.de
Web www.pfeifer.info
Office
Switzerland
pewag Suisse AG
Hasentalstrasse 8
CH-8934 Knonau
Tel. +41 44 768 55-55
Fax +41 44 768 55-30
E-Mail info@pewag-suisse.ch
Web www.pewag-suisse.ch
Agency

Feel free to contact us

Tel.

+49 8331 937-301

Inquiry

please leave empty!
* Required fields

Cookie settings

We use cookies to optimise our web page for you. By continuing to use the web page you agree to the use of cookies. Further information about cookies can be found in our data protection declaration.

Required cookies

Required cookies are mandatory for the basic functions of the website. Without these cookies, you will unfortunately not be able to use our website. These cookies are always set when you use the website. No personal data is collected or stored.

Functional cookies

These cookies allow us to analyze website usage so that we can measure and improve its performance. No personal data is collected or stored.

Data protection declaration