P 206

P 206
technical infos

Average fill factor

  • 0.72

average spinning loss factor 1770

  • 0.82

average spinning loss factor 1960

  • 0.82

average spinning loss factor 2160

  • 0.8

Core

  • steel core compacted

Lay type

  • lang lay

Lay direction

  • choice of right hand or left hand

Compacting

  • strands compacted – thereby extra wear resistant

Finish

  • bright

Rope diameter tolerance

  • 0/+4%

Indication

  • Please refer to our operating manual stranded ropes! Available at www.pfeifer.info/manual-strand-ropes

  • Sample schematic of rope construction used for representative purposes only. Actual construction dependent upon rope diameter.
Product variants
Nominal rope Ø [mm]
Minimum breaking force Fmin 1770 [kN]
Minimum breaking force Fmin 1960 [kN]
Minimum breaking force Fmin 2160 [kN]
Details
  • 10
    81.9
    89.6
    97.4
    Nominal rope Ø [mm] 10
    Weight approx. 49 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 81.9
    Minimum breaking force Fmin 1960 [kN] 89.6
    Minimum breaking force Fmin 2160 [kN] 97.4
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 11
    99.5
    108.8
    118.4
    Nominal rope Ø [mm] 11
    Weight approx. 60 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 99.5
    Minimum breaking force Fmin 1960 [kN] 108.8
    Minimum breaking force Fmin 2160 [kN] 118.4
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 12
    118.2
    130.8
    139.9
    Nominal rope Ø [mm] 12
    Weight approx. 71 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 118.2
    Minimum breaking force Fmin 1960 [kN] 130.8
    Minimum breaking force Fmin 2160 [kN] 139.9
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 13
    139
    152.7
    165.4
    Nominal rope Ø [mm] 13
    Weight approx. 83 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 139
    Minimum breaking force Fmin 1960 [kN] 152.7
    Minimum breaking force Fmin 2160 [kN] 165.4
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 14
    161.7
    179.1
    190.9
    Nominal rope Ø [mm] 14
    Weight approx. 96 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 161.7
    Minimum breaking force Fmin 1960 [kN] 179.1
    Minimum breaking force Fmin 2160 [kN] 190.9
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 15
    184.5
    204
    219.5
    Nominal rope Ø [mm] 15
    Weight approx. 110 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 184.5
    Minimum breaking force Fmin 1960 [kN] 204
    Minimum breaking force Fmin 2160 [kN] 219.5
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 16
    209.4
    230.6
    249.1
    Nominal rope Ø [mm] 16
    Weight approx. 127 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 209.4
    Minimum breaking force Fmin 1960 [kN] 230.6
    Minimum breaking force Fmin 2160 [kN] 249.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 17
    235.9
    257.9
    280.6
    Nominal rope Ø [mm] 17
    Weight approx. 142 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 235.9
    Minimum breaking force Fmin 1960 [kN] 257.9
    Minimum breaking force Fmin 2160 [kN] 280.6
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 18
    266.9
    293.9
    317.5
    Nominal rope Ø [mm] 18
    Weight approx. 160 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 266.9
    Minimum breaking force Fmin 1960 [kN] 293.9
    Minimum breaking force Fmin 2160 [kN] 317.5
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 19
    297.1
    329
    352.8
    Nominal rope Ø [mm] 19
    Weight approx. 178 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 297.1
    Minimum breaking force Fmin 1960 [kN] 329
    Minimum breaking force Fmin 2160 [kN] 352.8
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 20
    329.3
    362.2
    391.7
    Nominal rope Ø [mm] 20
    Weight approx. 198 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 329.3
    Minimum breaking force Fmin 1960 [kN] 362.2
    Minimum breaking force Fmin 2160 [kN] 391.7
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 21
    362.3
    396.1
    430.9
    Nominal rope Ø [mm] 21
    Weight approx. 217 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 362.3
    Minimum breaking force Fmin 1960 [kN] 396.1
    Minimum breaking force Fmin 2160 [kN] 430.9
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 22
    398.5
    441.4
    472
    Nominal rope Ø [mm] 22
    Weight approx. 238 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 398.5
    Minimum breaking force Fmin 1960 [kN] 441.4
    Minimum breaking force Fmin 2160 [kN] 472
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 23
    431.5
    471.8
    513.2
    Nominal rope Ø [mm] 23
    Weight approx. 261 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 431.5
    Minimum breaking force Fmin 1960 [kN] 471.8
    Minimum breaking force Fmin 2160 [kN] 513.2
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 24
    474.3
    524.3
    564.1
    Nominal rope Ø [mm] 24
    Weight approx. 284 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 474.3
    Minimum breaking force Fmin 1960 [kN] 524.3
    Minimum breaking force Fmin 2160 [kN] 564.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 25
    512.8
    567.9
    609.4
    Nominal rope Ø [mm] 25
    Weight approx. 304 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 512.8
    Minimum breaking force Fmin 1960 [kN] 567.9
    Minimum breaking force Fmin 2160 [kN] 609.4
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 26
    555
    614.9
    657.4
    Nominal rope Ø [mm] 26
    Weight approx. 329 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 555
    Minimum breaking force Fmin 1960 [kN] 614.9
    Minimum breaking force Fmin 2160 [kN] 657.4
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 27
    598.3
    654.2
    711.7
    Nominal rope Ø [mm] 27
    Weight approx. 357 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 598.3
    Minimum breaking force Fmin 1960 [kN] 654.2
    Minimum breaking force Fmin 2160 [kN] 711.7
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 28
    643.7
    712.9
    765.6
    Nominal rope Ø [mm] 28
    Weight approx. 385 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 643.7
    Minimum breaking force Fmin 1960 [kN] 712.9
    Minimum breaking force Fmin 2160 [kN] 765.6
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 29
    690.2
    754.6
    821
    Nominal rope Ø [mm] 29
    Weight approx. 412 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 690.2
    Minimum breaking force Fmin 1960 [kN] 754.6
    Minimum breaking force Fmin 2160 [kN] 821
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 30
    738.1
    817.4
    877.9
    Nominal rope Ø [mm] 30
    Weight approx. 440 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 738.1
    Minimum breaking force Fmin 1960 [kN] 817.4
    Minimum breaking force Fmin 2160 [kN] 877.9
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 31
    785.3
    869.7
    958.4
    Nominal rope Ø [mm] 31
    Weight approx. 470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 785.3
    Minimum breaking force Fmin 1960 [kN] 869.7
    Minimum breaking force Fmin 2160 [kN] 958.4
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 32
    843.4
    930
    1002.8
    Nominal rope Ø [mm] 32
    Weight approx. 504 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 843.4
    Minimum breaking force Fmin 1960 [kN] 930
    Minimum breaking force Fmin 2160 [kN] 1002.8
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 33
    896.6
    992.8
    1094.1
    Nominal rope Ø [mm] 33
    Weight approx. 536 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 896.6
    Minimum breaking force Fmin 1960 [kN] 992.8
    Minimum breaking force Fmin 2160 [kN] 1094.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 34
    950.8
    1045
    1130.9
    Nominal rope Ø [mm] 34
    Weight approx. 567 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 950.8
    Minimum breaking force Fmin 1960 [kN] 1045
    Minimum breaking force Fmin 2160 [kN] 1130.9
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 36
    1070
    1185
    1262.3
    Nominal rope Ø [mm] 36
    Weight approx. 640 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1070
    Minimum breaking force Fmin 1960 [kN] 1185
    Minimum breaking force Fmin 2160 [kN] 1262.3
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 38
    1191
    1319
    1412.2
    Nominal rope Ø [mm] 38
    Weight approx. 709 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1191
    Minimum breaking force Fmin 1960 [kN] 1319
    Minimum breaking force Fmin 2160 [kN] 1412.2
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 40
    1360
    1462
    1560.4
    Nominal rope Ø [mm] 40
    Weight approx. 792 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1360
    Minimum breaking force Fmin 1960 [kN] 1462
    Minimum breaking force Fmin 2160 [kN] 1560.4
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 42
    1455
    1611.2
    1667.4
    Nominal rope Ø [mm] 42
    Weight approx. 871 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1455
    Minimum breaking force Fmin 1960 [kN] 1611.2
    Minimum breaking force Fmin 2160 [kN] 1667.4
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 44
    1596
    1767
    1823.7
    Nominal rope Ø [mm] 44
    Weight approx. 955 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1596
    Minimum breaking force Fmin 1960 [kN] 1767
    Minimum breaking force Fmin 2160 [kN] 1823.7
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 46
    1748
    1935
    1989.7
    Nominal rope Ø [mm] 46
    Weight approx. 1048 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1748
    Minimum breaking force Fmin 1960 [kN] 1935
    Minimum breaking force Fmin 2160 [kN] 1989.7
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 48
    1908.4
    2113.3
    2187
    Nominal rope Ø [mm] 48
    Weight approx. 1140 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1908.4
    Minimum breaking force Fmin 1960 [kN] 2113.3
    Minimum breaking force Fmin 2160 [kN] 2187
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 50
    2052.5
    2272.8
    2504.7
    Nominal rope Ø [mm] 50
    Weight approx. 1230 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2052.5
    Minimum breaking force Fmin 1960 [kN] 2272.8
    Minimum breaking force Fmin 2160 [kN] 2504.7
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 52
    2223.2
    2461.8
    2713
    Nominal rope Ø [mm] 52
    Weight approx. 1333 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2223.2
    Minimum breaking force Fmin 1960 [kN] 2461.8
    Minimum breaking force Fmin 2160 [kN] 2713
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 54
    2394.2
    2651.2
    2921.7
    Nominal rope Ø [mm] 54
    Weight approx. 1435 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2394.2
    Minimum breaking force Fmin 1960 [kN] 2651.2
    Minimum breaking force Fmin 2160 [kN] 2921.7
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 56
    2574.8
    2851.2
    3142.2
    Nominal rope Ø [mm] 56
    Weight approx. 1543 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2574.8
    Minimum breaking force Fmin 1960 [kN] 2851.2
    Minimum breaking force Fmin 2160 [kN] 3142.2
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 58
    2762
    3058.5
    3370.6
    Nominal rope Ø [mm] 58
    Weight approx. 1656 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2762
    Minimum breaking force Fmin 1960 [kN] 3058.5
    Minimum breaking force Fmin 2160 [kN] 3370.6
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
  • 60
    2955.8
    3273.1
    3607.1
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 10
Minimum breaking force Fmin 1770 [kN] 81.9
Minimum breaking force Fmin 1960 [kN] 89.6
Minimum breaking force Fmin 2160 [kN] 97.4
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 11
Minimum breaking force Fmin 1770 [kN] 99.5
Minimum breaking force Fmin 1960 [kN] 108.8
Minimum breaking force Fmin 2160 [kN] 118.4
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 12
Minimum breaking force Fmin 1770 [kN] 118.2
Minimum breaking force Fmin 1960 [kN] 130.8
Minimum breaking force Fmin 2160 [kN] 139.9
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 13
Minimum breaking force Fmin 1770 [kN] 139
Minimum breaking force Fmin 1960 [kN] 152.7
Minimum breaking force Fmin 2160 [kN] 165.4
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 14
Minimum breaking force Fmin 1770 [kN] 161.7
Minimum breaking force Fmin 1960 [kN] 179.1
Minimum breaking force Fmin 2160 [kN] 190.9
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 15
Minimum breaking force Fmin 1770 [kN] 184.5
Minimum breaking force Fmin 1960 [kN] 204
Minimum breaking force Fmin 2160 [kN] 219.5
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 16
Minimum breaking force Fmin 1770 [kN] 209.4
Minimum breaking force Fmin 1960 [kN] 230.6
Minimum breaking force Fmin 2160 [kN] 249.1
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 17
Minimum breaking force Fmin 1770 [kN] 235.9
Minimum breaking force Fmin 1960 [kN] 257.9
Minimum breaking force Fmin 2160 [kN] 280.6
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 18
Minimum breaking force Fmin 1770 [kN] 266.9
Minimum breaking force Fmin 1960 [kN] 293.9
Minimum breaking force Fmin 2160 [kN] 317.5
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 19
Minimum breaking force Fmin 1770 [kN] 297.1
Minimum breaking force Fmin 1960 [kN] 329
Minimum breaking force Fmin 2160 [kN] 352.8
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 20
Minimum breaking force Fmin 1770 [kN] 329.3
Minimum breaking force Fmin 1960 [kN] 362.2
Minimum breaking force Fmin 2160 [kN] 391.7
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 21
Minimum breaking force Fmin 1770 [kN] 362.3
Minimum breaking force Fmin 1960 [kN] 396.1
Minimum breaking force Fmin 2160 [kN] 430.9
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 22
Minimum breaking force Fmin 1770 [kN] 398.5
Minimum breaking force Fmin 1960 [kN] 441.4
Minimum breaking force Fmin 2160 [kN] 472
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 23
Minimum breaking force Fmin 1770 [kN] 431.5
Minimum breaking force Fmin 1960 [kN] 471.8
Minimum breaking force Fmin 2160 [kN] 513.2
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 24
Minimum breaking force Fmin 1770 [kN] 474.3
Minimum breaking force Fmin 1960 [kN] 524.3
Minimum breaking force Fmin 2160 [kN] 564.1
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 25
Minimum breaking force Fmin 1770 [kN] 512.8
Minimum breaking force Fmin 1960 [kN] 567.9
Minimum breaking force Fmin 2160 [kN] 609.4
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 26
Minimum breaking force Fmin 1770 [kN] 555
Minimum breaking force Fmin 1960 [kN] 614.9
Minimum breaking force Fmin 2160 [kN] 657.4
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 27
Minimum breaking force Fmin 1770 [kN] 598.3
Minimum breaking force Fmin 1960 [kN] 654.2
Minimum breaking force Fmin 2160 [kN] 711.7
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 28
Minimum breaking force Fmin 1770 [kN] 643.7
Minimum breaking force Fmin 1960 [kN] 712.9
Minimum breaking force Fmin 2160 [kN] 765.6
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 29
Minimum breaking force Fmin 1770 [kN] 690.2
Minimum breaking force Fmin 1960 [kN] 754.6
Minimum breaking force Fmin 2160 [kN] 821
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 30
Minimum breaking force Fmin 1770 [kN] 738.1
Minimum breaking force Fmin 1960 [kN] 817.4
Minimum breaking force Fmin 2160 [kN] 877.9
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 31
Minimum breaking force Fmin 1770 [kN] 785.3
Minimum breaking force Fmin 1960 [kN] 869.7
Minimum breaking force Fmin 2160 [kN] 958.4
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 32
Minimum breaking force Fmin 1770 [kN] 843.4
Minimum breaking force Fmin 1960 [kN] 930
Minimum breaking force Fmin 2160 [kN] 1002.8
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 33
Minimum breaking force Fmin 1770 [kN] 896.6
Minimum breaking force Fmin 1960 [kN] 992.8
Minimum breaking force Fmin 2160 [kN] 1094.1
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 34
Minimum breaking force Fmin 1770 [kN] 950.8
Minimum breaking force Fmin 1960 [kN] 1045
Minimum breaking force Fmin 2160 [kN] 1130.9
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 36
Minimum breaking force Fmin 1770 [kN] 1070
Minimum breaking force Fmin 1960 [kN] 1185
Minimum breaking force Fmin 2160 [kN] 1262.3
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 38
Minimum breaking force Fmin 1770 [kN] 1191
Minimum breaking force Fmin 1960 [kN] 1319
Minimum breaking force Fmin 2160 [kN] 1412.2
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 40
Minimum breaking force Fmin 1770 [kN] 1360
Minimum breaking force Fmin 1960 [kN] 1462
Minimum breaking force Fmin 2160 [kN] 1560.4
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 42
Minimum breaking force Fmin 1770 [kN] 1455
Minimum breaking force Fmin 1960 [kN] 1611.2
Minimum breaking force Fmin 2160 [kN] 1667.4
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 44
Minimum breaking force Fmin 1770 [kN] 1596
Minimum breaking force Fmin 1960 [kN] 1767
Minimum breaking force Fmin 2160 [kN] 1823.7
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 46
Minimum breaking force Fmin 1770 [kN] 1748
Minimum breaking force Fmin 1960 [kN] 1935
Minimum breaking force Fmin 2160 [kN] 1989.7
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 48
Minimum breaking force Fmin 1770 [kN] 1908.4
Minimum breaking force Fmin 1960 [kN] 2113.3
Minimum breaking force Fmin 2160 [kN] 2187
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 50
Minimum breaking force Fmin 1770 [kN] 2052.5
Minimum breaking force Fmin 1960 [kN] 2272.8
Minimum breaking force Fmin 2160 [kN] 2504.7
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 52
Minimum breaking force Fmin 1770 [kN] 2223.2
Minimum breaking force Fmin 1960 [kN] 2461.8
Minimum breaking force Fmin 2160 [kN] 2713
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 54
Minimum breaking force Fmin 1770 [kN] 2394.2
Minimum breaking force Fmin 1960 [kN] 2651.2
Minimum breaking force Fmin 2160 [kN] 2921.7
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 56
Minimum breaking force Fmin 1770 [kN] 2574.8
Minimum breaking force Fmin 1960 [kN] 2851.2
Minimum breaking force Fmin 2160 [kN] 3142.2
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 58
Minimum breaking force Fmin 1770 [kN] 2762
Minimum breaking force Fmin 1960 [kN] 3058.5
Minimum breaking force Fmin 2160 [kN] 3370.6
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Nominal rope Ø [mm] 60
Minimum breaking force Fmin 1770 [kN] 2955.8
Minimum breaking force Fmin 1960 [kN] 3273.1
Minimum breaking force Fmin 2160 [kN] 3607.1
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1772 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2955.8
    Minimum breaking force Fmin 1960 [kN] 3273.1
    Minimum breaking force Fmin 2160 [kN] 3607.1
    Number of load-bearing wires in the external strands 126
    RCN according to ISO 4309 23-3
Other rope diameters and constructions on enquiry.
Downloads
Contact
Market Contact Location type
All other markets
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-301
Fax +49 8331 937-123
E-Mail wireropes@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Germany
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-181
Fax +49 8331 937-123
E-Mail seile@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Oktjaborskaja Nabereschnaja, No. 104, Korpus 23
RU-193079 St. Petersburg
Tel. +7 812 740 12-24
Fax +7 812 493 48-21
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Service centre
USA
PFEIFER Wire Rope & Lifting Technology Inc.
2023 Humble Westfield
US-Houston, TX 77037
Tel. +1 832 827 2923
Fax +1 281 784 2903
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Service centre
Austria
PFEIFER Seil- und Hebetechnik GmbH
Harterfeldweg 2
AT-4481 Asten
Tel. +43 7224 662 24-0
Fax +43 7224 662 24-13
E-Mail info@pfeifer-austria.at
Web www.pfeifer-austria.at
Sales subsidiary
China
PFEIFER Steel Wire Rope (Shanghai) Co., Ltd.
Building 1, No. 366 Chen Xiang Road, Nanxiang Town, Jiading District
CN-Shanghai 201802
Industrieseile/Industry ropes
Tel. +86 21 56 77 80 06
Fax +86 21 56 77 92 29
E-Mail info@pfeifer.com.cn
Web www.pfeifer.com.cn
Sales subsidiary
Great Britain
PFEIFER Rope & Tackle Ltd.
Unit 1A1, Marchwood Industrial Park, North Road
GB-Southampton SO40 4BL
Tel. +44 23 8066-5470
Fax +44 23 8066-5471
E-Mail sales@ropeandtackle.com
Web www.pfeifer-rt.com
Sales subsidiary
Hungary
PFEIFER Garant Kft.
Gyömrői út 108-126
HU-1103 Budapest
Tel. +36 1 260 10 14
Fax +36 1 262 09 27
E-Mail info@pfeifer-garant.hu
Web www.pfeifer-garant.hu
Sales subsidiary
Luxemburg
PFEIFER SOGEQUIP S.à.r.l.
Zone Ind. Schifflange-Foetz
LU-3844 Schifflange
Tel. +352 57 42-42
Fax +352 57 42-62
E-Mail info@pfeifer-sogequip.lu
Web www.pfeifer-sogequip.lu
Sales subsidiary
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Pyzhevskiy pereulok, h. 5, bld.1, office 108
RU-119017 Moskau
Tel. +7 495 363 01-27
Fax +7 495 363 01-28
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Sales subsidiary
Spain
PFEIFER Cables y Equipos de Elevación S.L.
Avda. de los Pirineos, 25 – Nave 20, San Sebastián de los Reyes
ES-28703 Madrid
Tel. +34 91 659-3185
Fax +34 91 659-3139
E-Mail p-es@pfeifer.es
Web www.pfeifer.es
Sales subsidiary
USA
PFEIFER Wire Rope & Lifting Technology Inc.
600 Industry Drive
US-Hampton, VA 23661
Tel. +1 757 825 2544
Fax +1 757 825 2546
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Sales subsidiary
United Arab Emirates
PFEIFER Middle East Wire Rope & Lifting Technology FZE
Jebel Ali Free Zone 1, RA08UA07, PO Box 263081
AE-Dubai
Tel. +971 4 883-8445
Fax +971 4 883-8446
E-Mail sales@pfeifer.ae
Web rope-lifting-ae.pfeifer.info
Sales subsidiary
Germany
PFEIFER Seil- und Hebetechnik GmbH
Krönenbarg 92b
DE-21077 Hamburg
Tel. +49 40 78 04 63-0
Fax +49 40 78 70 13
E-Mail psh-hamburg@pfeifer.de
Web www.pfeifer.info
Office
Switzerland
pewag Suisse AG
Hasentalstrasse 8
CH-8934 Knonau
Tel. +41 44 768 55-55
Fax +41 44 768 55-30
E-Mail info@pewag-suisse.ch
Web www.pewag-suisse.ch
Agency

Feel free to contact us

Tel.

+49 8331 937-301

Inquiry

please leave empty!
* Required fields

Cookie settings

We use cookies to optimise our web page for you. By continuing to use the web page you agree to the use of cookies. Further information about cookies can be found in our data protection declaration.

Required cookies

Required cookies are mandatory for the basic functions of the website. Without these cookies, you will unfortunately not be able to use our website. These cookies are always set when you use the website. No personal data is collected or stored.

Functional cookies

These cookies allow us to analyze website usage so that we can measure and improve its performance. No personal data is collected or stored.

Data protection declaration