P 1025

P 1025
technical infos

Average fill factor

  • 0.672

average spinning loss factor 1960

  • 0.85

average spinning loss factor 2160

  • 0.81

Core

  • full plastic impregnation of the compacted steel core to further extend fatigue life, improve structural stability

Lay direction

  • choice of right hand or left hand

Compacting

  • strands compacted – thereby extra wear resistant

Finish

  • choice of bright or galvanised

Rope diameter tolerance

  • +0/+5%

Indication

  • Please refer to our operating manual stranded ropes! Available at www.pfeifer.info/manual-strand-ropes

  • Sample schematic of rope construction used for representative purposes only. Actual construction dependent upon rope diameter.
Product variants
Nominal rope Ø [mm]
Minimum breaking force Fmin 1960 [kN]
Minimum breaking force Fmin 2160 [kN]
Details
  • 13
    149
    156.2
    Nominal rope Ø [mm] 13
    Weight approx. 77 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 149
    Minimum breaking force Fmin 2160 [kN] 156.2
    Number of load-bearing wires in the external strands 136
    RCN according to ISO 4309 03
  • 14
    174.8
    187
    Nominal rope Ø [mm] 14
    Weight approx. 90 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 174.8
    Minimum breaking force Fmin 2160 [kN] 187
    Number of load-bearing wires in the external strands 136
    RCN according to ISO 4309 03
  • 15
    202.7
    214
    Nominal rope Ø [mm] 15
    Weight approx. 103 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 202.7
    Minimum breaking force Fmin 2160 [kN] 214
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 16
    229.4
    242.4
    Nominal rope Ø [mm] 16
    Weight approx. 116 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 229.4
    Minimum breaking force Fmin 2160 [kN] 242.4
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 18
    288.2
    307
    Nominal rope Ø [mm] 18
    Weight approx. 149 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 288.2
    Minimum breaking force Fmin 2160 [kN] 307
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 19
    323.5
    342
    Nominal rope Ø [mm] 19
    Weight approx. 164 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 323.5
    Minimum breaking force Fmin 2160 [kN] 342
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 20
    355.5
    379
    Nominal rope Ø [mm] 20
    Weight approx. 184 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 355.5
    Minimum breaking force Fmin 2160 [kN] 379
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 22
    433.7
    458.5
    Nominal rope Ø [mm] 22
    Weight approx. 221 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 433.7
    Minimum breaking force Fmin 2160 [kN] 458.5
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 24
    514.3
    556
    Nominal rope Ø [mm] 24
    Weight approx. 263 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 514.3
    Minimum breaking force Fmin 2160 [kN] 556
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 25
    558.2
    602
    Nominal rope Ø [mm] 25
    Weight approx. 286 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 558.2
    Minimum breaking force Fmin 2160 [kN] 602
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 25.4
    572
    611
    Nominal rope Ø [mm] 25.4
    Weight approx. 298 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 572
    Minimum breaking force Fmin 2160 [kN] 611
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 26
    607.8
    655
    Nominal rope Ø [mm] 26
    Weight approx. 311 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 607.8
    Minimum breaking force Fmin 2160 [kN] 655
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 28
    697.3
    748
    Nominal rope Ø [mm] 28
    Weight approx. 357 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 697.3
    Minimum breaking force Fmin 2160 [kN] 748
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 30
    803
    864
    Nominal rope Ø [mm] 30
    Weight approx. 412 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 803
    Minimum breaking force Fmin 2160 [kN] 864
    Number of load-bearing wires in the external strands 248
    RCN according to ISO 4309 11
  • 32
    911
    968
    Nominal rope Ø [mm] 32
    Weight approx. 467 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 911
    Minimum breaking force Fmin 2160 [kN] 968
    Number of load-bearing wires in the external strands 248
    RCN according to ISO 4309 11
  • 34
    1024.9
    1091
    Nominal rope Ø [mm] 34
    Weight approx. 529 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 1024.9
    Minimum breaking force Fmin 2160 [kN] 1091
    Number of load-bearing wires in the external strands 248
    RCN according to ISO 4309 11
  • 36
    1150
    1217
    Nominal rope Ø [mm] 36
    Weight approx. 584 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 1150
    Minimum breaking force Fmin 2160 [kN] 1217
    Number of load-bearing wires in the external strands 248
    RCN according to ISO 4309 11
  • 38
    1270.6
    1332.5
    Nominal rope Ø [mm] 38
    Weight approx. 658 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 1270.6
    Minimum breaking force Fmin 2160 [kN] 1332.5
    Number of load-bearing wires in the external strands 248
    RCN according to ISO 4309 11
  • 40
    1409.8
    1478.6
    Nominal rope Ø [mm] 40
    Weight approx. 730 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 1409.8
    Minimum breaking force Fmin 2160 [kN] 1478.6
    Number of load-bearing wires in the external strands 248
    RCN according to ISO 4309 11
  • 42
    1538.4
    1613.3
    Nominal rope Ø [mm] 42
    Weight approx. 798 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 1538.4
    Minimum breaking force Fmin 2160 [kN] 1613.3
    Number of load-bearing wires in the external strands 248
    RCN according to ISO 4309 11
  • 44
    1735.6
    1820.2
    Nominal rope Ø [mm] 44
    Weight approx. 900 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 1735.6
    Minimum breaking force Fmin 2160 [kN] 1820.2
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 46
    1883.2
    1975
    Nominal rope Ø [mm] 46
    Weight approx. 978 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 1883.2
    Minimum breaking force Fmin 2160 [kN] 1975
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 48
    2055.3
    2155.5
    Nominal rope Ø [mm] 48
    Weight approx. 1061 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 2055.3
    Minimum breaking force Fmin 2160 [kN] 2155.5
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 50
    2252.9
    2362.7
    Nominal rope Ø [mm] 50
    Weight approx. 1162 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 2252.9
    Minimum breaking force Fmin 2160 [kN] 2362.7
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 52
    2426.9
    2545.2
    Nominal rope Ø [mm] 52
    Weight approx. 1251 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 2426.9
    Minimum breaking force Fmin 2160 [kN] 2545.2
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 54
    2607
    2734
    Nominal rope Ø [mm] 54
    Weight approx. 1349 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 2607
    Minimum breaking force Fmin 2160 [kN] 2734
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 56
    2805
    2941.7
    Nominal rope Ø [mm] 56
    Weight approx. 1459 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 2805
    Minimum breaking force Fmin 2160 [kN] 2941.7
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 58
    3020.9
    3168.1
    Nominal rope Ø [mm] 58
    Weight approx. 1569 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3020.9
    Minimum breaking force Fmin 2160 [kN] 3168.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 60
    3224
    3381.1
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 13
Minimum breaking force Fmin 1960 [kN] 149
Minimum breaking force Fmin 2160 [kN] 156.2
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 14
Minimum breaking force Fmin 1960 [kN] 174.8
Minimum breaking force Fmin 2160 [kN] 187
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 15
Minimum breaking force Fmin 1960 [kN] 202.7
Minimum breaking force Fmin 2160 [kN] 214
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 16
Minimum breaking force Fmin 1960 [kN] 229.4
Minimum breaking force Fmin 2160 [kN] 242.4
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 18
Minimum breaking force Fmin 1960 [kN] 288.2
Minimum breaking force Fmin 2160 [kN] 307
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 19
Minimum breaking force Fmin 1960 [kN] 323.5
Minimum breaking force Fmin 2160 [kN] 342
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 20
Minimum breaking force Fmin 1960 [kN] 355.5
Minimum breaking force Fmin 2160 [kN] 379
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 22
Minimum breaking force Fmin 1960 [kN] 433.7
Minimum breaking force Fmin 2160 [kN] 458.5
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 24
Minimum breaking force Fmin 1960 [kN] 514.3
Minimum breaking force Fmin 2160 [kN] 556
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 25
Minimum breaking force Fmin 1960 [kN] 558.2
Minimum breaking force Fmin 2160 [kN] 602
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 25.4
Minimum breaking force Fmin 1960 [kN] 572
Minimum breaking force Fmin 2160 [kN] 611
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 26
Minimum breaking force Fmin 1960 [kN] 607.8
Minimum breaking force Fmin 2160 [kN] 655
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 28
Minimum breaking force Fmin 1960 [kN] 697.3
Minimum breaking force Fmin 2160 [kN] 748
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 30
Minimum breaking force Fmin 1960 [kN] 803
Minimum breaking force Fmin 2160 [kN] 864
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 32
Minimum breaking force Fmin 1960 [kN] 911
Minimum breaking force Fmin 2160 [kN] 968
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 34
Minimum breaking force Fmin 1960 [kN] 1024.9
Minimum breaking force Fmin 2160 [kN] 1091
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 36
Minimum breaking force Fmin 1960 [kN] 1150
Minimum breaking force Fmin 2160 [kN] 1217
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 38
Minimum breaking force Fmin 1960 [kN] 1270.6
Minimum breaking force Fmin 2160 [kN] 1332.5
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 40
Minimum breaking force Fmin 1960 [kN] 1409.8
Minimum breaking force Fmin 2160 [kN] 1478.6
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 42
Minimum breaking force Fmin 1960 [kN] 1538.4
Minimum breaking force Fmin 2160 [kN] 1613.3
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 44
Minimum breaking force Fmin 1960 [kN] 1735.6
Minimum breaking force Fmin 2160 [kN] 1820.2
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 46
Minimum breaking force Fmin 1960 [kN] 1883.2
Minimum breaking force Fmin 2160 [kN] 1975
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 48
Minimum breaking force Fmin 1960 [kN] 2055.3
Minimum breaking force Fmin 2160 [kN] 2155.5
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 50
Minimum breaking force Fmin 1960 [kN] 2252.9
Minimum breaking force Fmin 2160 [kN] 2362.7
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 52
Minimum breaking force Fmin 1960 [kN] 2426.9
Minimum breaking force Fmin 2160 [kN] 2545.2
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 54
Minimum breaking force Fmin 1960 [kN] 2607
Minimum breaking force Fmin 2160 [kN] 2734
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 56
Minimum breaking force Fmin 1960 [kN] 2805
Minimum breaking force Fmin 2160 [kN] 2941.7
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 58
Minimum breaking force Fmin 1960 [kN] 3020.9
Minimum breaking force Fmin 2160 [kN] 3168.1
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Nominal rope Ø [mm] 60
Minimum breaking force Fmin 1960 [kN] 3224
Minimum breaking force Fmin 2160 [kN] 3381.1
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1671 [kg/100 m]
    Minimum breaking force Fmin 1960 [kN] 3224
    Minimum breaking force Fmin 2160 [kN] 3381.1
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
Other rope diameters and constructions on enquiry.
Downloads
Contact
Market Contact Location type
All other markets
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-301
Fax +49 8331 937-123
E-Mail wireropes@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Germany
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-181
Fax +49 8331 937-123
E-Mail seile@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Oktjaborskaja Nabereschnaja, No. 104, Korpus 23
RU-193079 St. Petersburg
Tel. +7 812 740 12-24
Fax +7 812 493 48-21
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Service centre
USA
PFEIFER Wire Rope & Lifting Technology Inc.
2023 Humble Westfield
US-Houston, TX 77037
Tel. +1 832 827 2923
Fax +1 281 784 2903
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Service centre
Austria
PFEIFER Seil- und Hebetechnik GmbH
Harterfeldweg 2
AT-4481 Asten
Tel. +43 7224 662 24-0
Fax +43 7224 662 24-13
E-Mail info@pfeifer-austria.at
Web www.pfeifer-austria.at
Sales subsidiary
China
PFEIFER Steel Wire Rope (Shanghai) Co., Ltd.
9th Floor, No. 2555 Jiayinyuan Road, Nanxiang Town, Jiading District
CN-Shanghai
Industrieseile/Industry ropes
Tel. +86 21 56 77 80 06
Fax +86 21 56 77 92 29
E-Mail info@pfeifer.com.cn
Web www.pfeifer.com.cn
Sales subsidiary
Great Britain
PFEIFER DRAKO Ltd.
Unit 1A1, Marchwood Industrial Park, North Road
GB-Southampton SO40 4BL
Tel. +44 23 8066-5470
Fax +44 23 8066-5471
E-Mail southampton@pfeifer.uk
Web www.pfeifer.co.uk
Sales subsidiary
Hungary
PFEIFER Garant Kft.
Gyömrői út 108-126
HU-1103 Budapest
Tel. +36 1 260 10 14
Fax +36 1 262 09 27
E-Mail info@pfeifer-garant.hu
Web www.pfeifer-garant.hu
Sales subsidiary
Luxemburg
PFEIFER SOGEQUIP S.à.r.l.
Zone Ind. Schifflange-Foetz
LU-3844 Schifflange
Tel. +352 57 42-42
Fax +352 57 42-62
E-Mail info@pfeifer-sogequip.lu
Web www.pfeifer-sogequip.lu
Sales subsidiary
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Pyzhevskiy pereulok, h. 5, bld.1, office 108
RU-119017 Moskau
Tel. +7 495 363 01-27
Fax +7 495 363 01-28
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Sales subsidiary
Spain
PFEIFER Cables y Equipos de Elevación S.L.
Avda. de los Pirineos, 25 – Nave 20, San Sebastián de los Reyes
ES-28703 Madrid
Tel. +34 91 659-3185
Fax +34 91 659-3139
E-Mail p-es@pfeifer.es
Web www.pfeifer.es
Sales subsidiary
USA
PFEIFER Wire Rope & Lifting Technology Inc.
600 Industry Drive
US-Hampton, VA 23661
Tel. +1 757 825 2544
Fax +1 757 825 2546
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Sales subsidiary
United Arab Emirates
PFEIFER Middle East Wire Rope & Lifting Technology FZE
Jebel Ali Free Zone 1, RA08UA07, PO Box 263081
AE-Dubai
Tel. +971 4 883-8445
Fax +971 4 883-8446
E-Mail sales@pfeifer.ae
Web rope-lifting-ae.pfeifer.info
Sales subsidiary
Germany
PFEIFER Seil- und Hebetechnik GmbH
Krönenbarg 92b
DE-21077 Hamburg
Tel. +49 40 78 04 63-0
Fax +49 40 78 70 13
E-Mail psh-hamburg@pfeifer.de
Web www.pfeifer.info
Office
Switzerland
pewag Suisse AG
Hasentalstrasse 8
CH-8934 Knonau
Tel. +41 44 768 55-55
Fax +41 44 768 55-30
E-Mail info@pewag-suisse.ch
Web www.pewag-suisse.ch
Agency

Feel free to contact us

Tel.

+49 8331 937-301

Inquiry

please leave empty!
* Required fields

Cookie settings

We use cookies to optimise our web page for you. By continuing to use the web page you agree to the use of cookies. Further information about cookies can be found in our data protection declaration.

Required cookies

Required cookies are mandatory for the basic functions of the website. Without these cookies, you will unfortunately not be able to use our website. These cookies are always set when you use the website. No personal data is collected or stored.

Functional cookies

These cookies allow us to analyze website usage so that we can measure and improve its performance. No personal data is collected or stored.

Data protection declaration