P 124

P 124
technical infos

Average fill factor

  • 0.6226

average spinning loss factor 1770

  • 0.845

average spinning loss factor 1960

  • 0.845

average spinning loss factor 2160

  • 0.835

Core

  • plastic coated steel core – therefore increased structural strength

Lay direction

  • choice of right hand or left hand

Compacting

  • not compacted

Finish

  • choice of bright or galvanised

Rope diameter tolerance

  • 0/+4,5%

Indication

  • Please refer to our operating manual stranded ropes! Available at www.pfeifer.info/manual-strand-ropes

  • Sample schematic of rope construction used for representative purposes only. Actual construction dependent upon rope diameter.
Safety

WARNING: Never use with a swivel – failure to comply may result in serious damages and injuries!
Product variants
Nominal rope Ø [mm]
Minimum breaking force Fmin 1770 [kN]
Minimum breaking force Fmin 1960 [kN]
Minimum breaking force Fmin 2160 [kN]
Details
  • 4
    11.7
    13
    14.1
    Nominal rope Ø 4
    Weight approx. 7 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 11.7
    Minimum breaking force Fmin 1960 [kN] 13
    Minimum breaking force Fmin 2160 [kN] 14.1
    Number of load-bearing wires in the external strands 56
    RCN according to ISO 4309 02
  • 5
    18.3
    20.2
    22
    Nominal rope Ø 5
    Weight approx. 11 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 18.3
    Minimum breaking force Fmin 1960 [kN] 20.2
    Minimum breaking force Fmin 2160 [kN] 22
    Number of load-bearing wires in the external strands 56
    RCN according to ISO 4309 02
  • 6
    26.3
    29.2
    31.7
    Nominal rope Ø 6
    Weight approx. 16 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 26.3
    Minimum breaking force Fmin 1960 [kN] 29.2
    Minimum breaking force Fmin 2160 [kN] 31.7
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 7
    35.8
    39.7
    43.2
    Nominal rope Ø 7
    Weight approx. 22 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 35.8
    Minimum breaking force Fmin 1960 [kN] 39.7
    Minimum breaking force Fmin 2160 [kN] 43.2
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 8
    43.7
    48.6
    53.4
    Nominal rope Ø 8
    Weight approx. 27 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 43.7
    Minimum breaking force Fmin 1960 [kN] 48.6
    Minimum breaking force Fmin 2160 [kN] 53.4
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 9
    56.9
    63.3
    69.3
    Nominal rope Ø 9
    Weight approx. 35 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 56.9
    Minimum breaking force Fmin 1960 [kN] 63.3
    Minimum breaking force Fmin 2160 [kN] 69.3
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 10
    68.2
    76
    83
    Nominal rope Ø 10
    Weight approx. 42 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 68.2
    Minimum breaking force Fmin 1960 [kN] 76
    Minimum breaking force Fmin 2160 [kN] 83
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 11
    86.3
    96.1
    105
    Nominal rope Ø 11
    Weight approx. 54 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 86.3
    Minimum breaking force Fmin 1960 [kN] 96.1
    Minimum breaking force Fmin 2160 [kN] 105
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 12
    106
    118
    129
    Nominal rope Ø 12
    Weight approx. 65 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 106
    Minimum breaking force Fmin 1960 [kN] 118
    Minimum breaking force Fmin 2160 [kN] 129
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 13
    122
    136
    148
    Nominal rope Ø 13
    Weight approx. 76 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 122
    Minimum breaking force Fmin 1960 [kN] 136
    Minimum breaking force Fmin 2160 [kN] 148
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 14
    137
    152
    166
    Nominal rope Ø 14
    Weight approx. 85 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 137
    Minimum breaking force Fmin 1960 [kN] 152
    Minimum breaking force Fmin 2160 [kN] 166
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 15
    166
    184
    201
    Nominal rope Ø 15
    Weight approx. 103 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 166
    Minimum breaking force Fmin 1960 [kN] 184
    Minimum breaking force Fmin 2160 [kN] 201
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 16
    187
    208
    227
    Nominal rope Ø 16
    Weight approx. 116 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 187
    Minimum breaking force Fmin 1960 [kN] 208
    Minimum breaking force Fmin 2160 [kN] 227
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 17
    210
    233
    254
    Nominal rope Ø 17
    Weight approx. 130 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 210
    Minimum breaking force Fmin 1960 [kN] 233
    Minimum breaking force Fmin 2160 [kN] 254
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 18
    236
    262
    286
    Nominal rope Ø 18
    Weight approx. 146 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 236
    Minimum breaking force Fmin 1960 [kN] 262
    Minimum breaking force Fmin 2160 [kN] 286
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 19
    260
    289
    316
    Nominal rope Ø 19
    Weight approx. 161 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 260
    Minimum breaking force Fmin 1960 [kN] 289
    Minimum breaking force Fmin 2160 [kN] 316
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 20
    288
    320
    348
    Nominal rope Ø 20
    Weight approx. 178 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 288
    Minimum breaking force Fmin 1960 [kN] 320
    Minimum breaking force Fmin 2160 [kN] 348
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 21
    315
    351
    382
    Nominal rope Ø 21
    Weight approx. 195 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 315
    Minimum breaking force Fmin 1960 [kN] 351
    Minimum breaking force Fmin 2160 [kN] 382
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 22
    361
    401
    437
    Nominal rope Ø 22
    Weight approx. 223 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 361
    Minimum breaking force Fmin 1960 [kN] 401
    Minimum breaking force Fmin 2160 [kN] 437
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 23
    390
    434
    473
    Nominal rope Ø 23
    Weight approx. 241 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 390
    Minimum breaking force Fmin 1960 [kN] 434
    Minimum breaking force Fmin 2160 [kN] 473
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 24
    422
    469
    511
    Nominal rope Ø 24
    Weight approx. 261 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 422
    Minimum breaking force Fmin 1960 [kN] 469
    Minimum breaking force Fmin 2160 [kN] 511
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 25
    462
    513
    559
    Nominal rope Ø 25
    Weight approx. 285 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 462
    Minimum breaking force Fmin 1960 [kN] 513
    Minimum breaking force Fmin 2160 [kN] 559
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 26
    497
    552
    601
    Nominal rope Ø 26
    Weight approx. 307 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 497
    Minimum breaking force Fmin 1960 [kN] 552
    Minimum breaking force Fmin 2160 [kN] 601
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 27
    528
    587
    640
    Nominal rope Ø 27
    Weight approx. 326 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 528
    Minimum breaking force Fmin 1960 [kN] 587
    Minimum breaking force Fmin 2160 [kN] 640
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 28
    580
    645
    701
    Nominal rope Ø 28
    Weight approx. 358 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 580
    Minimum breaking force Fmin 1960 [kN] 645
    Minimum breaking force Fmin 2160 [kN] 701
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 29
    620
    689
    749
    Nominal rope Ø 29
    Weight approx. 382 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 620
    Minimum breaking force Fmin 1960 [kN] 689
    Minimum breaking force Fmin 2160 [kN] 749
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 30
    663
    736
    802
    Nominal rope Ø 30
    Weight approx. 409 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 663
    Minimum breaking force Fmin 1960 [kN] 736
    Minimum breaking force Fmin 2160 [kN] 802
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 31
    703
    781
    850
    Nominal rope Ø 31
    Weight approx. 434 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 703
    Minimum breaking force Fmin 1960 [kN] 781
    Minimum breaking force Fmin 2160 [kN] 850
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 32
    745
    827
    901
    Nominal rope Ø 32
    Weight approx. 459 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 745
    Minimum breaking force Fmin 1960 [kN] 827
    Minimum breaking force Fmin 2160 [kN] 901
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 33
    806
    896
    975
    Nominal rope Ø 33
    Weight approx. 497 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 806
    Minimum breaking force Fmin 1960 [kN] 896
    Minimum breaking force Fmin 2160 [kN] 975
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 34
    855
    951
    1035
    Nominal rope Ø 34
    Weight approx. 528 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 855
    Minimum breaking force Fmin 1960 [kN] 951
    Minimum breaking force Fmin 2160 [kN] 1035
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 35
    884
    982
    1069
    Nominal rope Ø 35
    Weight approx. 545 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 884
    Minimum breaking force Fmin 1960 [kN] 982
    Minimum breaking force Fmin 2160 [kN] 1069
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 36
    953
    1058
    1152
    Nominal rope Ø 36
    Weight approx. 588 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 953
    Minimum breaking force Fmin 1960 [kN] 1058
    Minimum breaking force Fmin 2160 [kN] 1152
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 37
    1002
    1113
    1212
    Nominal rope Ø 37
    Weight approx. 618 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1002
    Minimum breaking force Fmin 1960 [kN] 1113
    Minimum breaking force Fmin 2160 [kN] 1212
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 38
    1069
    1188
    1293
    Nominal rope Ø 38
    Weight approx. 660 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1069
    Minimum breaking force Fmin 1960 [kN] 1188
    Minimum breaking force Fmin 2160 [kN] 1293
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 39
    1120
    1244
    1354
    Nominal rope Ø 39
    Weight approx. 691 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1120
    Minimum breaking force Fmin 1960 [kN] 1244
    Minimum breaking force Fmin 2160 [kN] 1354
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 40
    1180
    1311
    1427
    Nominal rope Ø 40
    Weight approx. 728 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1180
    Minimum breaking force Fmin 1960 [kN] 1311
    Minimum breaking force Fmin 2160 [kN] 1427
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 41
    1232
    1369
    1490
    Nominal rope Ø 41
    Weight approx. 760 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1232
    Minimum breaking force Fmin 1960 [kN] 1369
    Minimum breaking force Fmin 2160 [kN] 1490
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 42
    1307
    1452
    1581
    Nominal rope Ø 42
    Weight approx. 806 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1307
    Minimum breaking force Fmin 1960 [kN] 1452
    Minimum breaking force Fmin 2160 [kN] 1581
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 43
    1368
    1520
    1654
    Nominal rope Ø 43
    Weight approx. 844 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1368
    Minimum breaking force Fmin 1960 [kN] 1520
    Minimum breaking force Fmin 2160 [kN] 1654
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 44
    1434
    1594
    1734
    Nominal rope Ø 44
    Weight approx. 885 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1434
    Minimum breaking force Fmin 1960 [kN] 1594
    Minimum breaking force Fmin 2160 [kN] 1734
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 45
    1481
    1640
    1786
    Nominal rope Ø 45
    Weight approx. 911 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1481
    Minimum breaking force Fmin 1960 [kN] 1640
    Minimum breaking force Fmin 2160 [kN] 1786
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 46
    1550
    1723
    1875
    Nominal rope Ø 46
    Weight approx. 956 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1550
    Minimum breaking force Fmin 1960 [kN] 1723
    Minimum breaking force Fmin 2160 [kN] 1875
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 47
    1616
    1789
    1948
    Nominal rope Ø 47
    Weight approx. 994 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1616
    Minimum breaking force Fmin 1960 [kN] 1789
    Minimum breaking force Fmin 2160 [kN] 1948
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 48
    1678
    1864
    2029
    Nominal rope Ø 48
    Weight approx. 1035 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1678
    Minimum breaking force Fmin 1960 [kN] 1864
    Minimum breaking force Fmin 2160 [kN] 2029
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 49
    1756
    1944
    2118
    Nominal rope Ø 49
    Weight approx. 1080 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1756
    Minimum breaking force Fmin 1960 [kN] 1944
    Minimum breaking force Fmin 2160 [kN] 2118
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 06
  • 50
    1824
    2027
    2206
    Nominal rope Ø 50
    Weight approx. 1125 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1824
    Minimum breaking force Fmin 1960 [kN] 2027
    Minimum breaking force Fmin 2160 [kN] 2206
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 51
    1902
    2107
    2294
    Nominal rope Ø 51
    Weight approx. 1170 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1902
    Minimum breaking force Fmin 1960 [kN] 2107
    Minimum breaking force Fmin 2160 [kN] 2294
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 52
    1951
    2168
    2359
    Nominal rope Ø 52
    Weight approx. 1203 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1951
    Minimum breaking force Fmin 1960 [kN] 2168
    Minimum breaking force Fmin 2160 [kN] 2359
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 53
    2054
    2275
    2477
    Nominal rope Ø 53
    Weight approx. 1264 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2054
    Minimum breaking force Fmin 1960 [kN] 2275
    Minimum breaking force Fmin 2160 [kN] 2477
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 54
    2133
    2369
    2578
    Nominal rope Ø 54
    Weight approx. 1315 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2133
    Minimum breaking force Fmin 1960 [kN] 2369
    Minimum breaking force Fmin 2160 [kN] 2578
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 55
    2212
    2450
    2668
    Nominal rope Ø 55
    Weight approx. 1361 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2212
    Minimum breaking force Fmin 1960 [kN] 2450
    Minimum breaking force Fmin 2160 [kN] 2668
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 56
    2323
    2581
    2808
    Nominal rope Ø 56
    Weight approx. 1432 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2323
    Minimum breaking force Fmin 1960 [kN] 2581
    Minimum breaking force Fmin 2160 [kN] 2808
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 57
    2376
    2631
    2866
    Nominal rope Ø 57
    Weight approx. 1462 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2376
    Minimum breaking force Fmin 1960 [kN] 2631
    Minimum breaking force Fmin 2160 [kN] 2866
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 58
    2482
    2758
    3001
    Nominal rope Ø 58
    Weight approx. 1531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2482
    Minimum breaking force Fmin 1960 [kN] 2758
    Minimum breaking force Fmin 2160 [kN] 3001
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 59
    2546
    2819
    3070
    Nominal rope Ø 59
    Weight approx. 1566 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2546
    Minimum breaking force Fmin 1960 [kN] 2819
    Minimum breaking force Fmin 2160 [kN] 3070
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 60
    2659
    2954
    3214
    Nominal rope Ø 60
    Weight approx. 1640 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2659
    Minimum breaking force Fmin 1960 [kN] 2954
    Minimum breaking force Fmin 2160 [kN] 3214
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 61
    2722
    3013
    3282
    Nominal rope Ø 61
    Weight approx. 1674 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2722
    Minimum breaking force Fmin 1960 [kN] 3013
    Minimum breaking force Fmin 2160 [kN] 3282
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 62
    2811
    3113
    3390
    Nominal rope Ø 62
    Weight approx. 1729 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2811
    Minimum breaking force Fmin 1960 [kN] 3113
    Minimum breaking force Fmin 2160 [kN] 3390
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 63
    2903
    3214
    3500
    Nominal rope Ø 63
    Weight approx. 1786 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2903
    Minimum breaking force Fmin 1960 [kN] 3214
    Minimum breaking force Fmin 2160 [kN] 3500
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 64
    2996
    3317
    3612
    Nominal rope Ø 64
    Weight approx. 1843 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2996
    Minimum breaking force Fmin 1960 [kN] 3317
    Minimum breaking force Fmin 2160 [kN] 3612
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 65
    3090
    3421
    3727
    Nominal rope Ø 65
    Weight approx. 1901 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3090
    Minimum breaking force Fmin 1960 [kN] 3421
    Minimum breaking force Fmin 2160 [kN] 3727
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 66
    3186
    3528
    3842
    Nominal rope Ø 66
    Weight approx. 1960 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3186
    Minimum breaking force Fmin 1960 [kN] 3528
    Minimum breaking force Fmin 2160 [kN] 3842
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 67
    3283
    3635
    3959
    Nominal rope Ø 67
    Weight approx. 2019 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3283
    Minimum breaking force Fmin 1960 [kN] 3635
    Minimum breaking force Fmin 2160 [kN] 3959
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 68
    3382
    3745
    4078
    Nominal rope Ø 68
    Weight approx. 2080 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3382
    Minimum breaking force Fmin 1960 [kN] 3745
    Minimum breaking force Fmin 2160 [kN] 4078
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 69
    3482
    3856
    4199
    Nominal rope Ø 69
    Weight approx. 2142 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3482
    Minimum breaking force Fmin 1960 [kN] 3856
    Minimum breaking force Fmin 2160 [kN] 4199
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 70
    3584
    3968
    4321
    Nominal rope Ø 70
    Weight approx. 2204 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3584
    Minimum breaking force Fmin 1960 [kN] 3968
    Minimum breaking force Fmin 2160 [kN] 4321
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 71
    3687
    4082
    4446
    Nominal rope Ø 71
    Weight approx. 2268 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3687
    Minimum breaking force Fmin 1960 [kN] 4082
    Minimum breaking force Fmin 2160 [kN] 4446
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 72
    3792
    4198
    4572
    Nominal rope Ø 72
    Weight approx. 2332 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3792
    Minimum breaking force Fmin 1960 [kN] 4198
    Minimum breaking force Fmin 2160 [kN] 4572
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 73
    3897
    4315
    4700
    Nominal rope Ø 73
    Weight approx. 2397 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3897
    Minimum breaking force Fmin 1960 [kN] 4315
    Minimum breaking force Fmin 2160 [kN] 4700
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 74
    4005
    4435
    4830
    Nominal rope Ø 74
    Weight approx. 2463 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4005
    Minimum breaking force Fmin 1960 [kN] 4435
    Minimum breaking force Fmin 2160 [kN] 4830
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 75
    4114
    4555
    4961
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 4
Minimum breaking force Fmin 1770 [kN] 11.7
Minimum breaking force Fmin 1960 [kN] 13
Minimum breaking force Fmin 2160 [kN] 14.1
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 5
Minimum breaking force Fmin 1770 [kN] 18.3
Minimum breaking force Fmin 1960 [kN] 20.2
Minimum breaking force Fmin 2160 [kN] 22
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 6
Minimum breaking force Fmin 1770 [kN] 26.3
Minimum breaking force Fmin 1960 [kN] 29.2
Minimum breaking force Fmin 2160 [kN] 31.7
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 7
Minimum breaking force Fmin 1770 [kN] 35.8
Minimum breaking force Fmin 1960 [kN] 39.7
Minimum breaking force Fmin 2160 [kN] 43.2
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 8
Minimum breaking force Fmin 1770 [kN] 43.7
Minimum breaking force Fmin 1960 [kN] 48.6
Minimum breaking force Fmin 2160 [kN] 53.4
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 9
Minimum breaking force Fmin 1770 [kN] 56.9
Minimum breaking force Fmin 1960 [kN] 63.3
Minimum breaking force Fmin 2160 [kN] 69.3
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 10
Minimum breaking force Fmin 1770 [kN] 68.2
Minimum breaking force Fmin 1960 [kN] 76
Minimum breaking force Fmin 2160 [kN] 83
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 11
Minimum breaking force Fmin 1770 [kN] 86.3
Minimum breaking force Fmin 1960 [kN] 96.1
Minimum breaking force Fmin 2160 [kN] 105
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 12
Minimum breaking force Fmin 1770 [kN] 106
Minimum breaking force Fmin 1960 [kN] 118
Minimum breaking force Fmin 2160 [kN] 129
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 13
Minimum breaking force Fmin 1770 [kN] 122
Minimum breaking force Fmin 1960 [kN] 136
Minimum breaking force Fmin 2160 [kN] 148
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 14
Minimum breaking force Fmin 1770 [kN] 137
Minimum breaking force Fmin 1960 [kN] 152
Minimum breaking force Fmin 2160 [kN] 166
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 15
Minimum breaking force Fmin 1770 [kN] 166
Minimum breaking force Fmin 1960 [kN] 184
Minimum breaking force Fmin 2160 [kN] 201
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 16
Minimum breaking force Fmin 1770 [kN] 187
Minimum breaking force Fmin 1960 [kN] 208
Minimum breaking force Fmin 2160 [kN] 227
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 17
Minimum breaking force Fmin 1770 [kN] 210
Minimum breaking force Fmin 1960 [kN] 233
Minimum breaking force Fmin 2160 [kN] 254
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 18
Minimum breaking force Fmin 1770 [kN] 236
Minimum breaking force Fmin 1960 [kN] 262
Minimum breaking force Fmin 2160 [kN] 286
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 19
Minimum breaking force Fmin 1770 [kN] 260
Minimum breaking force Fmin 1960 [kN] 289
Minimum breaking force Fmin 2160 [kN] 316
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 20
Minimum breaking force Fmin 1770 [kN] 288
Minimum breaking force Fmin 1960 [kN] 320
Minimum breaking force Fmin 2160 [kN] 348
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 21
Minimum breaking force Fmin 1770 [kN] 315
Minimum breaking force Fmin 1960 [kN] 351
Minimum breaking force Fmin 2160 [kN] 382
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 22
Minimum breaking force Fmin 1770 [kN] 361
Minimum breaking force Fmin 1960 [kN] 401
Minimum breaking force Fmin 2160 [kN] 437
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 23
Minimum breaking force Fmin 1770 [kN] 390
Minimum breaking force Fmin 1960 [kN] 434
Minimum breaking force Fmin 2160 [kN] 473
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 24
Minimum breaking force Fmin 1770 [kN] 422
Minimum breaking force Fmin 1960 [kN] 469
Minimum breaking force Fmin 2160 [kN] 511
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 25
Minimum breaking force Fmin 1770 [kN] 462
Minimum breaking force Fmin 1960 [kN] 513
Minimum breaking force Fmin 2160 [kN] 559
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 26
Minimum breaking force Fmin 1770 [kN] 497
Minimum breaking force Fmin 1960 [kN] 552
Minimum breaking force Fmin 2160 [kN] 601
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 27
Minimum breaking force Fmin 1770 [kN] 528
Minimum breaking force Fmin 1960 [kN] 587
Minimum breaking force Fmin 2160 [kN] 640
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 28
Minimum breaking force Fmin 1770 [kN] 580
Minimum breaking force Fmin 1960 [kN] 645
Minimum breaking force Fmin 2160 [kN] 701
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 29
Minimum breaking force Fmin 1770 [kN] 620
Minimum breaking force Fmin 1960 [kN] 689
Minimum breaking force Fmin 2160 [kN] 749
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 30
Minimum breaking force Fmin 1770 [kN] 663
Minimum breaking force Fmin 1960 [kN] 736
Minimum breaking force Fmin 2160 [kN] 802
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 31
Minimum breaking force Fmin 1770 [kN] 703
Minimum breaking force Fmin 1960 [kN] 781
Minimum breaking force Fmin 2160 [kN] 850
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 32
Minimum breaking force Fmin 1770 [kN] 745
Minimum breaking force Fmin 1960 [kN] 827
Minimum breaking force Fmin 2160 [kN] 901
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 33
Minimum breaking force Fmin 1770 [kN] 806
Minimum breaking force Fmin 1960 [kN] 896
Minimum breaking force Fmin 2160 [kN] 975
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 34
Minimum breaking force Fmin 1770 [kN] 855
Minimum breaking force Fmin 1960 [kN] 951
Minimum breaking force Fmin 2160 [kN] 1035
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 35
Minimum breaking force Fmin 1770 [kN] 884
Minimum breaking force Fmin 1960 [kN] 982
Minimum breaking force Fmin 2160 [kN] 1069
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 36
Minimum breaking force Fmin 1770 [kN] 953
Minimum breaking force Fmin 1960 [kN] 1058
Minimum breaking force Fmin 2160 [kN] 1152
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 37
Minimum breaking force Fmin 1770 [kN] 1002
Minimum breaking force Fmin 1960 [kN] 1113
Minimum breaking force Fmin 2160 [kN] 1212
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 38
Minimum breaking force Fmin 1770 [kN] 1069
Minimum breaking force Fmin 1960 [kN] 1188
Minimum breaking force Fmin 2160 [kN] 1293
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 39
Minimum breaking force Fmin 1770 [kN] 1120
Minimum breaking force Fmin 1960 [kN] 1244
Minimum breaking force Fmin 2160 [kN] 1354
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 40
Minimum breaking force Fmin 1770 [kN] 1180
Minimum breaking force Fmin 1960 [kN] 1311
Minimum breaking force Fmin 2160 [kN] 1427
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 41
Minimum breaking force Fmin 1770 [kN] 1232
Minimum breaking force Fmin 1960 [kN] 1369
Minimum breaking force Fmin 2160 [kN] 1490
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 42
Minimum breaking force Fmin 1770 [kN] 1307
Minimum breaking force Fmin 1960 [kN] 1452
Minimum breaking force Fmin 2160 [kN] 1581
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 43
Minimum breaking force Fmin 1770 [kN] 1368
Minimum breaking force Fmin 1960 [kN] 1520
Minimum breaking force Fmin 2160 [kN] 1654
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 44
Minimum breaking force Fmin 1770 [kN] 1434
Minimum breaking force Fmin 1960 [kN] 1594
Minimum breaking force Fmin 2160 [kN] 1734
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 45
Minimum breaking force Fmin 1770 [kN] 1481
Minimum breaking force Fmin 1960 [kN] 1640
Minimum breaking force Fmin 2160 [kN] 1786
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 46
Minimum breaking force Fmin 1770 [kN] 1550
Minimum breaking force Fmin 1960 [kN] 1723
Minimum breaking force Fmin 2160 [kN] 1875
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 47
Minimum breaking force Fmin 1770 [kN] 1616
Minimum breaking force Fmin 1960 [kN] 1789
Minimum breaking force Fmin 2160 [kN] 1948
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 48
Minimum breaking force Fmin 1770 [kN] 1678
Minimum breaking force Fmin 1960 [kN] 1864
Minimum breaking force Fmin 2160 [kN] 2029
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 49
Minimum breaking force Fmin 1770 [kN] 1756
Minimum breaking force Fmin 1960 [kN] 1944
Minimum breaking force Fmin 2160 [kN] 2118
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 50
Minimum breaking force Fmin 1770 [kN] 1824
Minimum breaking force Fmin 1960 [kN] 2027
Minimum breaking force Fmin 2160 [kN] 2206
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 51
Minimum breaking force Fmin 1770 [kN] 1902
Minimum breaking force Fmin 1960 [kN] 2107
Minimum breaking force Fmin 2160 [kN] 2294
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 52
Minimum breaking force Fmin 1770 [kN] 1951
Minimum breaking force Fmin 1960 [kN] 2168
Minimum breaking force Fmin 2160 [kN] 2359
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 53
Minimum breaking force Fmin 1770 [kN] 2054
Minimum breaking force Fmin 1960 [kN] 2275
Minimum breaking force Fmin 2160 [kN] 2477
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 54
Minimum breaking force Fmin 1770 [kN] 2133
Minimum breaking force Fmin 1960 [kN] 2369
Minimum breaking force Fmin 2160 [kN] 2578
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 55
Minimum breaking force Fmin 1770 [kN] 2212
Minimum breaking force Fmin 1960 [kN] 2450
Minimum breaking force Fmin 2160 [kN] 2668
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 56
Minimum breaking force Fmin 1770 [kN] 2323
Minimum breaking force Fmin 1960 [kN] 2581
Minimum breaking force Fmin 2160 [kN] 2808
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 57
Minimum breaking force Fmin 1770 [kN] 2376
Minimum breaking force Fmin 1960 [kN] 2631
Minimum breaking force Fmin 2160 [kN] 2866
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 58
Minimum breaking force Fmin 1770 [kN] 2482
Minimum breaking force Fmin 1960 [kN] 2758
Minimum breaking force Fmin 2160 [kN] 3001
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 59
Minimum breaking force Fmin 1770 [kN] 2546
Minimum breaking force Fmin 1960 [kN] 2819
Minimum breaking force Fmin 2160 [kN] 3070
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 60
Minimum breaking force Fmin 1770 [kN] 2659
Minimum breaking force Fmin 1960 [kN] 2954
Minimum breaking force Fmin 2160 [kN] 3214
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 61
Minimum breaking force Fmin 1770 [kN] 2722
Minimum breaking force Fmin 1960 [kN] 3013
Minimum breaking force Fmin 2160 [kN] 3282
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 62
Minimum breaking force Fmin 1770 [kN] 2811
Minimum breaking force Fmin 1960 [kN] 3113
Minimum breaking force Fmin 2160 [kN] 3390
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 63
Minimum breaking force Fmin 1770 [kN] 2903
Minimum breaking force Fmin 1960 [kN] 3214
Minimum breaking force Fmin 2160 [kN] 3500
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 64
Minimum breaking force Fmin 1770 [kN] 2996
Minimum breaking force Fmin 1960 [kN] 3317
Minimum breaking force Fmin 2160 [kN] 3612
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 65
Minimum breaking force Fmin 1770 [kN] 3090
Minimum breaking force Fmin 1960 [kN] 3421
Minimum breaking force Fmin 2160 [kN] 3727
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 66
Minimum breaking force Fmin 1770 [kN] 3186
Minimum breaking force Fmin 1960 [kN] 3528
Minimum breaking force Fmin 2160 [kN] 3842
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 67
Minimum breaking force Fmin 1770 [kN] 3283
Minimum breaking force Fmin 1960 [kN] 3635
Minimum breaking force Fmin 2160 [kN] 3959
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 68
Minimum breaking force Fmin 1770 [kN] 3382
Minimum breaking force Fmin 1960 [kN] 3745
Minimum breaking force Fmin 2160 [kN] 4078
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 69
Minimum breaking force Fmin 1770 [kN] 3482
Minimum breaking force Fmin 1960 [kN] 3856
Minimum breaking force Fmin 2160 [kN] 4199
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 70
Minimum breaking force Fmin 1770 [kN] 3584
Minimum breaking force Fmin 1960 [kN] 3968
Minimum breaking force Fmin 2160 [kN] 4321
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 71
Minimum breaking force Fmin 1770 [kN] 3687
Minimum breaking force Fmin 1960 [kN] 4082
Minimum breaking force Fmin 2160 [kN] 4446
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 72
Minimum breaking force Fmin 1770 [kN] 3792
Minimum breaking force Fmin 1960 [kN] 4198
Minimum breaking force Fmin 2160 [kN] 4572
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 73
Minimum breaking force Fmin 1770 [kN] 3897
Minimum breaking force Fmin 1960 [kN] 4315
Minimum breaking force Fmin 2160 [kN] 4700
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 74
Minimum breaking force Fmin 1770 [kN] 4005
Minimum breaking force Fmin 1960 [kN] 4435
Minimum breaking force Fmin 2160 [kN] 4830
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 75
Minimum breaking force Fmin 1770 [kN] 4114
Minimum breaking force Fmin 1960 [kN] 4555
Minimum breaking force Fmin 2160 [kN] 4961
  • Details
    Nominal rope Ø 75
    Weight approx. 2531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4114
    Minimum breaking force Fmin 1960 [kN] 4555
    Minimum breaking force Fmin 2160 [kN] 4961
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Other rope diameters and constructions on enquiry.
Downloads
Contact
Market Contact Location type
All other markets
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-301
Fax +49 8331 937-123
E-Mail wireropes@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Germany
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-181
Fax +49 8331 937-123
E-Mail seile@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Oktjaborskaja Nabereschnaja, No. 104, Korpus 23
RU-193079 St. Petersburg
Tel. +7 812 740 12-24
Fax +7 812 493 48-21
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Service centre
USA
PFEIFER Wire Rope & Lifting Technology Inc.
2023 Humble Westfield
US-Houston, TX 77037
Tel. +1 832 827 2923
Fax +1 281 784 2903
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Service centre
Austria
PFEIFER Seil- und Hebetechnik GmbH
Harterfeldweg 2
AT-4481 Asten
Tel. +43 7224 662 24-0
Fax +43 7224 662 24-13
E-Mail info@pfeifer-austria.at
Web www.pfeifer-austria.at
Sales subsidiary
China
PFEIFER Steel Wire Rope (Shanghai) Co., Ltd.
Building 1, No. 366 Chen Xiang Road, Nanxiang Town, Jiading District
CN-Shanghai 201802
Industrieseile/Industry ropes
Tel. +86 21 56 77 80 06
Fax +86 21 56 77 92 29
E-Mail info@pfeifer.com.cn
Web www.pfeifer.com.cn
Sales subsidiary
Great Britain
PFEIFER Rope & Tackle Ltd.
Unit 1A1, Marchwood Industrial Park, North Road
GB-Southampton SO40 4BL
Tel. +44 23 8066-5470
Fax +44 23 8066-5471
E-Mail sales@ropeandtackle.com
Web www.pfeifer-rt.com
Sales subsidiary
Hungary
PFEIFER Garant Kft.
Gyömrői út 108-126
HU-1103 Budapest
Tel. +36 1 260 10 14
Fax +36 1 262 09 27
E-Mail info@pfeifer-garant.hu
Web www.pfeifer-garant.hu
Sales subsidiary
Luxemburg
PFEIFER SOGEQUIP S.à.r.l.
Zone Ind. Schifflange-Foetz
LU-3844 Schifflange
Tel. +352 57 42-42
Fax +352 57 42-62
E-Mail info@pfeifer-sogequip.lu
Web www.pfeifer-sogequip.lu
Sales subsidiary
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Pyzhevskiy pereulok, h. 5, bld.1, office 108
RU-119017 Moskau
Tel. +7 495 363 01-27
Fax +7 495 363 01-28
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Sales subsidiary
Spain
PFEIFER Cables y Equipos de Elevación S.L.
Avda. de los Pirineos, 25 – Nave 20, San Sebastián de los Reyes
ES-28703 Madrid
Tel. +34 91 659-3185
Fax +34 91 659-3139
E-Mail p-es@pfeifer.es
Web www.pfeifer.es
Sales subsidiary
USA
PFEIFER Wire Rope & Lifting Technology Inc.
600 Industry Drive
US-Hampton, VA 23661
Tel. +1 757 825 2544
Fax +1 757 825 2546
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Sales subsidiary
United Arab Emirates
PFEIFER Middle East Wire Rope & Lifting Technology FZE
Jebel Ali Free Zone 1, RA08UA07, PO Box 263081
AE-Dubai
Tel. +971 4 883-8445
Fax +971 4 883-8446
E-Mail sales@pfeifer.ae
Web rope-lifting-ae.pfeifer.info
Sales subsidiary
Germany
PFEIFER Seil- und Hebetechnik GmbH
Krönenbarg 92b
DE-21077 Hamburg
Tel. +49 40 78 04 63-0
Fax +49 40 78 70 13
E-Mail psh-hamburg@pfeifer.de
Web www.pfeifer.info
Office
Switzerland
pewag Suisse AG
Hasentalstrasse 8
CH-8934 Knonau
Tel. +41 44 768 55-55
Fax +41 44 768 55-30
E-Mail info@pewag-suisse.ch
Web www.pewag-suisse.ch
Agency

Feel free to contact us

Tel.

+49 8331 937-301

Inquiry

please leave empty!
* Required fields

Cookie settings

We use cookies to optimise our web page for you. By continuing to use the web page you agree to the use of cookies. Further information about cookies can be found in our data protection declaration.

Required cookies

Required cookies are mandatory for the basic functions of the website. Without these cookies, you will unfortunately not be able to use our website. These cookies are always set when you use the website. No personal data is collected or stored.

Functional cookies

These cookies allow us to analyze website usage so that we can measure and improve its performance. No personal data is collected or stored.

Data protection declaration