P 129

P 129
technical infos

Average fill factor

  • 0.675

average spinning loss factor 1770

  • 0.85

average spinning loss factor 1960

  • 0.85

average spinning loss factor 2160

  • 0.84

Core

  • plastic coated steel core – therefore increased structural strength

Lay type

  • choice of regular/ordinary lay or langs lay

Lay direction

  • choice of right hand or left hand

Compacting

  • strands compacted – thereby extra wear resistant

Finish

  • choice of bright or galvanised

Rope diameter tolerance

  • 0 / +4,5%

Indication

  • Please refer to our operating manual stranded ropes! Available at www.pfeifer.info/manual-strand-ropes

  • Sample schematic of rope construction used for representative purposes only. Actual construction dependent upon rope diameter.
Safety

WARNING: Never use with a swivel – failure to comply may result in serious damages and injuries!
Product variants
Nominal rope Ø [mm]
Minimum breaking force Fmin 1770 [kN]
Minimum breaking force Fmin 1960 [kN]
Minimum breaking force Fmin 2160 [kN]
Details
  • 4
    12.8
    14.1
    15.4
    Nominal rope Ø 4
    Weight approx. 8 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 12.8
    Minimum breaking force Fmin 1960 [kN] 14.1
    Minimum breaking force Fmin 2160 [kN] 15.4
    Number of load-bearing wires in the external strands 56
    RCN according to ISO 4309 02
  • 5
    19.9
    22.1
    24
    Nominal rope Ø 5
    Weight approx. 12 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 19.9
    Minimum breaking force Fmin 1960 [kN] 22.1
    Minimum breaking force Fmin 2160 [kN] 24
    Number of load-bearing wires in the external strands 56
    RCN according to ISO 4309 02
  • 6
    28.7
    31.8
    34.6
    Nominal rope Ø 6
    Weight approx. 17 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 28.7
    Minimum breaking force Fmin 1960 [kN] 31.8
    Minimum breaking force Fmin 2160 [kN] 34.6
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 04
  • 7
    39.1
    43.3
    47.1
    Nominal rope Ø 7
    Weight approx. 23 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 39.1
    Minimum breaking force Fmin 1960 [kN] 43.3
    Minimum breaking force Fmin 2160 [kN] 47.1
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 04
  • 8
    51
    56.5
    61.6
    Nominal rope Ø 8
    Weight approx. 30 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 51
    Minimum breaking force Fmin 1960 [kN] 56.5
    Minimum breaking force Fmin 2160 [kN] 61.6
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 04
  • 9
    64.6
    71.5
    77.9
    Nominal rope Ø 9
    Weight approx. 38 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 64.6
    Minimum breaking force Fmin 1960 [kN] 71.5
    Minimum breaking force Fmin 2160 [kN] 77.9
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 04
  • 10
    79.8
    88.4
    96.6
    Nominal rope Ø 10
    Weight approx. 47 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 79.8
    Minimum breaking force Fmin 1960 [kN] 88.4
    Minimum breaking force Fmin 2160 [kN] 96.6
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 04
  • 11
    96.9
    107
    117
    Nominal rope Ø 11
    Weight approx. 57 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 96.9
    Minimum breaking force Fmin 1960 [kN] 107
    Minimum breaking force Fmin 2160 [kN] 117
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 04
  • 12
    115
    128
    139
    Nominal rope Ø 12
    Weight approx. 68 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 115
    Minimum breaking force Fmin 1960 [kN] 128
    Minimum breaking force Fmin 2160 [kN] 139
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 04
  • 13
    135
    150
    163
    Nominal rope Ø 13
    Weight approx. 80 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 135
    Minimum breaking force Fmin 1960 [kN] 150
    Minimum breaking force Fmin 2160 [kN] 163
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 04
  • 14
    156
    173
    188
    Nominal rope Ø 14
    Weight approx. 92 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 156
    Minimum breaking force Fmin 1960 [kN] 173
    Minimum breaking force Fmin 2160 [kN] 188
    Number of load-bearing wires in the external strands 152
    RCN according to ISO 4309 04
  • 15
    179
    199
    217
    Nominal rope Ø 15
    Weight approx. 106 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 179
    Minimum breaking force Fmin 1960 [kN] 199
    Minimum breaking force Fmin 2160 [kN] 217
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 16
    204
    226
    246
    Nominal rope Ø 16
    Weight approx. 121 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 204
    Minimum breaking force Fmin 1960 [kN] 226
    Minimum breaking force Fmin 2160 [kN] 246
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 17
    230
    255
    278
    Nominal rope Ø 17
    Weight approx. 136 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 230
    Minimum breaking force Fmin 1960 [kN] 255
    Minimum breaking force Fmin 2160 [kN] 278
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 18
    258
    286
    312
    Nominal rope Ø 18
    Weight approx. 153 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 258
    Minimum breaking force Fmin 1960 [kN] 286
    Minimum breaking force Fmin 2160 [kN] 312
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 19
    288
    319
    347
    Nominal rope Ø 19
    Weight approx. 170 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 288
    Minimum breaking force Fmin 1960 [kN] 319
    Minimum breaking force Fmin 2160 [kN] 347
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 20
    319
    354
    385
    Nominal rope Ø 20
    Weight approx. 189 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 319
    Minimum breaking force Fmin 1960 [kN] 354
    Minimum breaking force Fmin 2160 [kN] 385
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 21
    352
    389
    424
    Nominal rope Ø 21
    Weight approx. 208 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 352
    Minimum breaking force Fmin 1960 [kN] 389
    Minimum breaking force Fmin 2160 [kN] 424
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 22
    386
    428
    465
    Nominal rope Ø 22
    Weight approx. 228 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 386
    Minimum breaking force Fmin 1960 [kN] 428
    Minimum breaking force Fmin 2160 [kN] 465
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 23
    422
    468
    509
    Nominal rope Ø 23
    Weight approx. 250 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 422
    Minimum breaking force Fmin 1960 [kN] 468
    Minimum breaking force Fmin 2160 [kN] 509
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 24
    459
    509
    554
    Nominal rope Ø 24
    Weight approx. 272 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 459
    Minimum breaking force Fmin 1960 [kN] 509
    Minimum breaking force Fmin 2160 [kN] 554
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 25
    498
    552
    601
    Nominal rope Ø 25
    Weight approx. 295 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 498
    Minimum breaking force Fmin 1960 [kN] 552
    Minimum breaking force Fmin 2160 [kN] 601
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 26
    539
    597
    650
    Nominal rope Ø 26
    Weight approx. 319 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 539
    Minimum breaking force Fmin 1960 [kN] 597
    Minimum breaking force Fmin 2160 [kN] 650
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 27
    581
    643
    701
    Nominal rope Ø 27
    Weight approx. 344 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 581
    Minimum breaking force Fmin 1960 [kN] 643
    Minimum breaking force Fmin 2160 [kN] 701
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 28
    626
    693
    754
    Nominal rope Ø 28
    Weight approx. 370 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 626
    Minimum breaking force Fmin 1960 [kN] 693
    Minimum breaking force Fmin 2160 [kN] 754
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 29
    671
    743
    809
    Nominal rope Ø 29
    Weight approx. 397 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 671
    Minimum breaking force Fmin 1960 [kN] 743
    Minimum breaking force Fmin 2160 [kN] 809
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 30
    718
    795
    866
    Nominal rope Ø 30
    Weight approx. 425 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 718
    Minimum breaking force Fmin 1960 [kN] 795
    Minimum breaking force Fmin 2160 [kN] 866
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 31
    772
    855
    932
    Nominal rope Ø 31
    Weight approx. 457 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 772
    Minimum breaking force Fmin 1960 [kN] 855
    Minimum breaking force Fmin 2160 [kN] 932
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 32
    823
    911
    992
    Nominal rope Ø 32
    Weight approx. 487 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 823
    Minimum breaking force Fmin 1960 [kN] 911
    Minimum breaking force Fmin 2160 [kN] 992
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 33
    875
    969
    1055
    Nominal rope Ø 33
    Weight approx. 518 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 875
    Minimum breaking force Fmin 1960 [kN] 969
    Minimum breaking force Fmin 2160 [kN] 1055
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 34
    929
    1030
    1121
    Nominal rope Ø 34
    Weight approx. 549 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 929
    Minimum breaking force Fmin 1960 [kN] 1030
    Minimum breaking force Fmin 2160 [kN] 1121
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 35
    984
    1090
    1187
    Nominal rope Ø 35
    Weight approx. 582 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 984
    Minimum breaking force Fmin 1960 [kN] 1090
    Minimum breaking force Fmin 2160 [kN] 1187
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 36
    1041
    1153
    1256
    Nominal rope Ø 36
    Weight approx. 616 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1041
    Minimum breaking force Fmin 1960 [kN] 1153
    Minimum breaking force Fmin 2160 [kN] 1256
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 37
    1100
    1221
    1328
    Nominal rope Ø 37
    Weight approx. 651 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1100
    Minimum breaking force Fmin 1960 [kN] 1221
    Minimum breaking force Fmin 2160 [kN] 1328
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 38
    1168
    1298
    1413
    Nominal rope Ø 38
    Weight approx. 686 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1168
    Minimum breaking force Fmin 1960 [kN] 1298
    Minimum breaking force Fmin 2160 [kN] 1413
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 39
    1222
    1353
    1474
    Nominal rope Ø 39
    Weight approx. 723 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1222
    Minimum breaking force Fmin 1960 [kN] 1353
    Minimum breaking force Fmin 2160 [kN] 1474
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 40
    1285
    1424
    1551
    Nominal rope Ø 40
    Weight approx. 761 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1285
    Minimum breaking force Fmin 1960 [kN] 1424
    Minimum breaking force Fmin 2160 [kN] 1551
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 41
    1351
    1496
    1629
    Nominal rope Ø 41
    Weight approx. 799 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1351
    Minimum breaking force Fmin 1960 [kN] 1496
    Minimum breaking force Fmin 2160 [kN] 1629
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 42
    1418
    1574
    1713
    Nominal rope Ø 42
    Weight approx. 838 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1418
    Minimum breaking force Fmin 1960 [kN] 1574
    Minimum breaking force Fmin 2160 [kN] 1713
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 43
    1486
    1645
    1792
    Nominal rope Ø 43
    Weight approx. 879 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1486
    Minimum breaking force Fmin 1960 [kN] 1645
    Minimum breaking force Fmin 2160 [kN] 1792
    Number of load-bearing wires in the external strands 208
    RCN according to ISO 4309 09
  • 44
    1556
    1723
    1876
    Nominal rope Ø 44
    Weight approx. 920 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1556
    Minimum breaking force Fmin 1960 [kN] 1723
    Minimum breaking force Fmin 2160 [kN] 1876
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 45
    1615
    1788
    1948
    Nominal rope Ø 45
    Weight approx. 955 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1615
    Minimum breaking force Fmin 1960 [kN] 1788
    Minimum breaking force Fmin 2160 [kN] 1948
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 46
    1700
    1883
    2050
    Nominal rope Ø 46
    Weight approx. 1006 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1700
    Minimum breaking force Fmin 1960 [kN] 1883
    Minimum breaking force Fmin 2160 [kN] 2050
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 47
    1762
    1951
    2125
    Nominal rope Ø 47
    Weight approx. 1042 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1762
    Minimum breaking force Fmin 1960 [kN] 1951
    Minimum breaking force Fmin 2160 [kN] 2125
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 48
    1851
    2050
    2233
    Nominal rope Ø 48
    Weight approx. 1095 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1851
    Minimum breaking force Fmin 1960 [kN] 2050
    Minimum breaking force Fmin 2160 [kN] 2233
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 49
    1915
    2121
    2309
    Nominal rope Ø 49
    Weight approx. 1133 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1915
    Minimum breaking force Fmin 1960 [kN] 2121
    Minimum breaking force Fmin 2160 [kN] 2309
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 50
    2009
    2224
    2423
    Nominal rope Ø 50
    Weight approx. 1188 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2009
    Minimum breaking force Fmin 1960 [kN] 2224
    Minimum breaking force Fmin 2160 [kN] 2423
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 51
    2075
    2298
    2502
    Nominal rope Ø 51
    Weight approx. 1227 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2075
    Minimum breaking force Fmin 1960 [kN] 2298
    Minimum breaking force Fmin 2160 [kN] 2502
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 52
    2173
    2406
    2620
    Nominal rope Ø 52
    Weight approx. 1285 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2173
    Minimum breaking force Fmin 1960 [kN] 2406
    Minimum breaking force Fmin 2160 [kN] 2620
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 53
    2241
    2481
    2702
    Nominal rope Ø 53
    Weight approx. 1325 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2241
    Minimum breaking force Fmin 1960 [kN] 2481
    Minimum breaking force Fmin 2160 [kN] 2702
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 54
    2343
    2594
    2826
    Nominal rope Ø 54
    Weight approx. 1386 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2343
    Minimum breaking force Fmin 1960 [kN] 2594
    Minimum breaking force Fmin 2160 [kN] 2826
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 55
    2413
    2672
    2910
    Nominal rope Ø 55
    Weight approx. 1427 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2413
    Minimum breaking force Fmin 1960 [kN] 2672
    Minimum breaking force Fmin 2160 [kN] 2910
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 56
    2519
    2791
    3039
    Nominal rope Ø 56
    Weight approx. 1491 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2519
    Minimum breaking force Fmin 1960 [kN] 2791
    Minimum breaking force Fmin 2160 [kN] 3039
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 57
    2592
    2870
    3125
    Nominal rope Ø 57
    Weight approx. 1533 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2592
    Minimum breaking force Fmin 1960 [kN] 2870
    Minimum breaking force Fmin 2160 [kN] 3125
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 58
    2703
    2993
    3260
    Nominal rope Ø 58
    Weight approx. 1599 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2703
    Minimum breaking force Fmin 1960 [kN] 2993
    Minimum breaking force Fmin 2160 [kN] 3260
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 59
    2776
    3074
    3348
    Nominal rope Ø 59
    Weight approx. 1642 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2776
    Minimum breaking force Fmin 1960 [kN] 3074
    Minimum breaking force Fmin 2160 [kN] 3348
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 60
    2893
    3203
    3489
    Nominal rope Ø 60
    Weight approx. 1711 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2893
    Minimum breaking force Fmin 1960 [kN] 3203
    Minimum breaking force Fmin 2160 [kN] 3489
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 61
    2968
    3286
    3579
    Nominal rope Ø 61
    Weight approx. 1756 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2968
    Minimum breaking force Fmin 1960 [kN] 3286
    Minimum breaking force Fmin 2160 [kN] 3579
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 62
    3089
    3420
    3725
    Nominal rope Ø 62
    Weight approx. 1827 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3089
    Minimum breaking force Fmin 1960 [kN] 3420
    Minimum breaking force Fmin 2160 [kN] 3725
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 63
    3165
    3505
    3818
    Nominal rope Ø 63
    Weight approx. 1873 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3165
    Minimum breaking force Fmin 1960 [kN] 3505
    Minimum breaking force Fmin 2160 [kN] 3818
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 64
    3291
    3645
    3969
    Nominal rope Ø 64
    Weight approx. 1947 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3291
    Minimum breaking force Fmin 1960 [kN] 3645
    Minimum breaking force Fmin 2160 [kN] 3969
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 65
    3370
    3732
    4064
    Nominal rope Ø 65
    Weight approx. 1993 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3370
    Minimum breaking force Fmin 1960 [kN] 3732
    Minimum breaking force Fmin 2160 [kN] 4064
    Number of load-bearing wires in the external strands 288
    RCN according to ISO 4309 13
  • 66
    3500
    3876
    4221
    Nominal rope Ø 66
    Weight approx. 2071 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3500
    Minimum breaking force Fmin 1960 [kN] 3876
    Minimum breaking force Fmin 2160 [kN] 4221
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 67
    3580
    3964
    4318
    Nominal rope Ø 67
    Weight approx. 2118 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3580
    Minimum breaking force Fmin 1960 [kN] 3964
    Minimum breaking force Fmin 2160 [kN] 4318
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 68
    3715
    4114
    4481
    Nominal rope Ø 68
    Weight approx. 2198 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3715
    Minimum breaking force Fmin 1960 [kN] 4114
    Minimum breaking force Fmin 2160 [kN] 4481
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 69
    3798
    4205
    4580
    Nominal rope Ø 69
    Weight approx. 2246 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3798
    Minimum breaking force Fmin 1960 [kN] 4205
    Minimum breaking force Fmin 2160 [kN] 4580
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 70
    3937
    4360
    4749
    Nominal rope Ø 70
    Weight approx. 2329 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3937
    Minimum breaking force Fmin 1960 [kN] 4360
    Minimum breaking force Fmin 2160 [kN] 4749
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 71
    4021
    4452
    4849
    Nominal rope Ø 71
    Weight approx. 2378 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4021
    Minimum breaking force Fmin 1960 [kN] 4452
    Minimum breaking force Fmin 2160 [kN] 4849
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 72
    4134
    4579
    4986
    Nominal rope Ø 72
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4134
    Minimum breaking force Fmin 1960 [kN] 4579
    Minimum breaking force Fmin 2160 [kN] 4986
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 73
    4251
    4706
    5126
    Nominal rope Ø 73
    Weight approx. 2514 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4251
    Minimum breaking force Fmin 1960 [kN] 4706
    Minimum breaking force Fmin 2160 [kN] 5126
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 74
    4367
    4837
    5268
    Nominal rope Ø 74
    Weight approx. 2584 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4367
    Minimum breaking force Fmin 1960 [kN] 4837
    Minimum breaking force Fmin 2160 [kN] 5268
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 75
    4486
    4968
    5410
    Nominal rope Ø 75
    Weight approx. 2654 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4486
    Minimum breaking force Fmin 1960 [kN] 4968
    Minimum breaking force Fmin 2160 [kN] 5410
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 76
    4607
    5102
    Nominal rope Ø 76
    Weight approx. 2725 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4607
    Minimum breaking force Fmin 1960 [kN] 5102
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 77
    4729
    5237
    Nominal rope Ø 77
    Weight approx. 2797 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4729
    Minimum breaking force Fmin 1960 [kN] 5237
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 78
    4853
    5374
    Nominal rope Ø 78
    Weight approx. 2871 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4853
    Minimum breaking force Fmin 1960 [kN] 5374
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 79
    4978
    5512
    Nominal rope Ø 79
    Weight approx. 2945 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4978
    Minimum breaking force Fmin 1960 [kN] 5512
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 80
    5104
    5653
    Nominal rope Ø 80
    Weight approx. 3020 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5104
    Minimum breaking force Fmin 1960 [kN] 5653
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 81
    5233
    5794
    Nominal rope Ø 81
    Weight approx. 3096 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5233
    Minimum breaking force Fmin 1960 [kN] 5794
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 82
    5364
    5939
    Nominal rope Ø 82
    Weight approx. 3173 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5364
    Minimum breaking force Fmin 1960 [kN] 5939
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 83
    5494
    6084
    Nominal rope Ø 83
    Weight approx. 3250 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5494
    Minimum breaking force Fmin 1960 [kN] 6084
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 84
    5628
    6232
    Nominal rope Ø 84
    Weight approx. 3329 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5628
    Minimum breaking force Fmin 1960 [kN] 6232
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 85
    5763
    6381
    Nominal rope Ø 85
    Weight approx. 3409 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5763
    Minimum breaking force Fmin 1960 [kN] 6381
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 86
    5899
    6532
    Nominal rope Ø 86
    Weight approx. 3490 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5899
    Minimum breaking force Fmin 1960 [kN] 6532
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 87
    6037
    6685
    Nominal rope Ø 87
    Weight approx. 3571 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 6037
    Minimum breaking force Fmin 1960 [kN] 6685
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 88
    6177
    6840
    Nominal rope Ø 88
    Weight approx. 3654 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 6177
    Minimum breaking force Fmin 1960 [kN] 6840
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 89
    6318
    6996
    Nominal rope Ø 89
    Weight approx. 3737 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 6318
    Minimum breaking force Fmin 1960 [kN] 6996
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 90
    6461
    7154
    Nominal rope Ø 90
    Weight approx. 3822 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 6461
    Minimum breaking force Fmin 1960 [kN] 7154
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 91
    6605
    7314
    Nominal rope Ø 91
    Weight approx. 3907 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 6605
    Minimum breaking force Fmin 1960 [kN] 7314
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 92
    6751
    7476
    Nominal rope Ø 92
    Weight approx. 3994 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 6751
    Minimum breaking force Fmin 1960 [kN] 7476
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 93
    6899
    7639
    Nominal rope Ø 93
    Weight approx. 4081 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 6899
    Minimum breaking force Fmin 1960 [kN] 7639
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 94
    7047
    7804
    Nominal rope Ø 94
    Weight approx. 4169 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7047
    Minimum breaking force Fmin 1960 [kN] 7804
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 95
    7199
    7971
    Nominal rope Ø 95
    Weight approx. 4258 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7199
    Minimum breaking force Fmin 1960 [kN] 7971
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 96
    7351
    8140
    Nominal rope Ø 96
    Weight approx. 4348 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7351
    Minimum breaking force Fmin 1960 [kN] 8140
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 97
    7505
    8310
    Nominal rope Ø 97
    Weight approx. 4439 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7505
    Minimum breaking force Fmin 1960 [kN] 8310
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 98
    7660
    8482
    Nominal rope Ø 98
    Weight approx. 4531 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7660
    Minimum breaking force Fmin 1960 [kN] 8482
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 99
    7817
    8656
    Nominal rope Ø 99
    Weight approx. 4624 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7817
    Minimum breaking force Fmin 1960 [kN] 8656
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
  • 100
    7976
    8832
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 4
Minimum breaking force Fmin 1770 [kN] 12.8
Minimum breaking force Fmin 1960 [kN] 14.1
Minimum breaking force Fmin 2160 [kN] 15.4
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 5
Minimum breaking force Fmin 1770 [kN] 19.9
Minimum breaking force Fmin 1960 [kN] 22.1
Minimum breaking force Fmin 2160 [kN] 24
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 6
Minimum breaking force Fmin 1770 [kN] 28.7
Minimum breaking force Fmin 1960 [kN] 31.8
Minimum breaking force Fmin 2160 [kN] 34.6
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 7
Minimum breaking force Fmin 1770 [kN] 39.1
Minimum breaking force Fmin 1960 [kN] 43.3
Minimum breaking force Fmin 2160 [kN] 47.1
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 8
Minimum breaking force Fmin 1770 [kN] 51
Minimum breaking force Fmin 1960 [kN] 56.5
Minimum breaking force Fmin 2160 [kN] 61.6
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 9
Minimum breaking force Fmin 1770 [kN] 64.6
Minimum breaking force Fmin 1960 [kN] 71.5
Minimum breaking force Fmin 2160 [kN] 77.9
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 10
Minimum breaking force Fmin 1770 [kN] 79.8
Minimum breaking force Fmin 1960 [kN] 88.4
Minimum breaking force Fmin 2160 [kN] 96.6
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 11
Minimum breaking force Fmin 1770 [kN] 96.9
Minimum breaking force Fmin 1960 [kN] 107
Minimum breaking force Fmin 2160 [kN] 117
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 12
Minimum breaking force Fmin 1770 [kN] 115
Minimum breaking force Fmin 1960 [kN] 128
Minimum breaking force Fmin 2160 [kN] 139
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 13
Minimum breaking force Fmin 1770 [kN] 135
Minimum breaking force Fmin 1960 [kN] 150
Minimum breaking force Fmin 2160 [kN] 163
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 14
Minimum breaking force Fmin 1770 [kN] 156
Minimum breaking force Fmin 1960 [kN] 173
Minimum breaking force Fmin 2160 [kN] 188
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 15
Minimum breaking force Fmin 1770 [kN] 179
Minimum breaking force Fmin 1960 [kN] 199
Minimum breaking force Fmin 2160 [kN] 217
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 16
Minimum breaking force Fmin 1770 [kN] 204
Minimum breaking force Fmin 1960 [kN] 226
Minimum breaking force Fmin 2160 [kN] 246
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 17
Minimum breaking force Fmin 1770 [kN] 230
Minimum breaking force Fmin 1960 [kN] 255
Minimum breaking force Fmin 2160 [kN] 278
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 18
Minimum breaking force Fmin 1770 [kN] 258
Minimum breaking force Fmin 1960 [kN] 286
Minimum breaking force Fmin 2160 [kN] 312
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 19
Minimum breaking force Fmin 1770 [kN] 288
Minimum breaking force Fmin 1960 [kN] 319
Minimum breaking force Fmin 2160 [kN] 347
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 20
Minimum breaking force Fmin 1770 [kN] 319
Minimum breaking force Fmin 1960 [kN] 354
Minimum breaking force Fmin 2160 [kN] 385
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 21
Minimum breaking force Fmin 1770 [kN] 352
Minimum breaking force Fmin 1960 [kN] 389
Minimum breaking force Fmin 2160 [kN] 424
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 22
Minimum breaking force Fmin 1770 [kN] 386
Minimum breaking force Fmin 1960 [kN] 428
Minimum breaking force Fmin 2160 [kN] 465
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 23
Minimum breaking force Fmin 1770 [kN] 422
Minimum breaking force Fmin 1960 [kN] 468
Minimum breaking force Fmin 2160 [kN] 509
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 24
Minimum breaking force Fmin 1770 [kN] 459
Minimum breaking force Fmin 1960 [kN] 509
Minimum breaking force Fmin 2160 [kN] 554
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 25
Minimum breaking force Fmin 1770 [kN] 498
Minimum breaking force Fmin 1960 [kN] 552
Minimum breaking force Fmin 2160 [kN] 601
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 26
Minimum breaking force Fmin 1770 [kN] 539
Minimum breaking force Fmin 1960 [kN] 597
Minimum breaking force Fmin 2160 [kN] 650
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 27
Minimum breaking force Fmin 1770 [kN] 581
Minimum breaking force Fmin 1960 [kN] 643
Minimum breaking force Fmin 2160 [kN] 701
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 28
Minimum breaking force Fmin 1770 [kN] 626
Minimum breaking force Fmin 1960 [kN] 693
Minimum breaking force Fmin 2160 [kN] 754
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 29
Minimum breaking force Fmin 1770 [kN] 671
Minimum breaking force Fmin 1960 [kN] 743
Minimum breaking force Fmin 2160 [kN] 809
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 30
Minimum breaking force Fmin 1770 [kN] 718
Minimum breaking force Fmin 1960 [kN] 795
Minimum breaking force Fmin 2160 [kN] 866
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 31
Minimum breaking force Fmin 1770 [kN] 772
Minimum breaking force Fmin 1960 [kN] 855
Minimum breaking force Fmin 2160 [kN] 932
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 32
Minimum breaking force Fmin 1770 [kN] 823
Minimum breaking force Fmin 1960 [kN] 911
Minimum breaking force Fmin 2160 [kN] 992
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 33
Minimum breaking force Fmin 1770 [kN] 875
Minimum breaking force Fmin 1960 [kN] 969
Minimum breaking force Fmin 2160 [kN] 1055
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 34
Minimum breaking force Fmin 1770 [kN] 929
Minimum breaking force Fmin 1960 [kN] 1030
Minimum breaking force Fmin 2160 [kN] 1121
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 35
Minimum breaking force Fmin 1770 [kN] 984
Minimum breaking force Fmin 1960 [kN] 1090
Minimum breaking force Fmin 2160 [kN] 1187
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 36
Minimum breaking force Fmin 1770 [kN] 1041
Minimum breaking force Fmin 1960 [kN] 1153
Minimum breaking force Fmin 2160 [kN] 1256
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 37
Minimum breaking force Fmin 1770 [kN] 1100
Minimum breaking force Fmin 1960 [kN] 1221
Minimum breaking force Fmin 2160 [kN] 1328
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 38
Minimum breaking force Fmin 1770 [kN] 1168
Minimum breaking force Fmin 1960 [kN] 1298
Minimum breaking force Fmin 2160 [kN] 1413
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 39
Minimum breaking force Fmin 1770 [kN] 1222
Minimum breaking force Fmin 1960 [kN] 1353
Minimum breaking force Fmin 2160 [kN] 1474
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 40
Minimum breaking force Fmin 1770 [kN] 1285
Minimum breaking force Fmin 1960 [kN] 1424
Minimum breaking force Fmin 2160 [kN] 1551
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 41
Minimum breaking force Fmin 1770 [kN] 1351
Minimum breaking force Fmin 1960 [kN] 1496
Minimum breaking force Fmin 2160 [kN] 1629
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 42
Minimum breaking force Fmin 1770 [kN] 1418
Minimum breaking force Fmin 1960 [kN] 1574
Minimum breaking force Fmin 2160 [kN] 1713
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 43
Minimum breaking force Fmin 1770 [kN] 1486
Minimum breaking force Fmin 1960 [kN] 1645
Minimum breaking force Fmin 2160 [kN] 1792
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 44
Minimum breaking force Fmin 1770 [kN] 1556
Minimum breaking force Fmin 1960 [kN] 1723
Minimum breaking force Fmin 2160 [kN] 1876
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 45
Minimum breaking force Fmin 1770 [kN] 1615
Minimum breaking force Fmin 1960 [kN] 1788
Minimum breaking force Fmin 2160 [kN] 1948
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 46
Minimum breaking force Fmin 1770 [kN] 1700
Minimum breaking force Fmin 1960 [kN] 1883
Minimum breaking force Fmin 2160 [kN] 2050
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 47
Minimum breaking force Fmin 1770 [kN] 1762
Minimum breaking force Fmin 1960 [kN] 1951
Minimum breaking force Fmin 2160 [kN] 2125
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 48
Minimum breaking force Fmin 1770 [kN] 1851
Minimum breaking force Fmin 1960 [kN] 2050
Minimum breaking force Fmin 2160 [kN] 2233
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 49
Minimum breaking force Fmin 1770 [kN] 1915
Minimum breaking force Fmin 1960 [kN] 2121
Minimum breaking force Fmin 2160 [kN] 2309
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 50
Minimum breaking force Fmin 1770 [kN] 2009
Minimum breaking force Fmin 1960 [kN] 2224
Minimum breaking force Fmin 2160 [kN] 2423
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 51
Minimum breaking force Fmin 1770 [kN] 2075
Minimum breaking force Fmin 1960 [kN] 2298
Minimum breaking force Fmin 2160 [kN] 2502
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 52
Minimum breaking force Fmin 1770 [kN] 2173
Minimum breaking force Fmin 1960 [kN] 2406
Minimum breaking force Fmin 2160 [kN] 2620
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 53
Minimum breaking force Fmin 1770 [kN] 2241
Minimum breaking force Fmin 1960 [kN] 2481
Minimum breaking force Fmin 2160 [kN] 2702
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 54
Minimum breaking force Fmin 1770 [kN] 2343
Minimum breaking force Fmin 1960 [kN] 2594
Minimum breaking force Fmin 2160 [kN] 2826
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 55
Minimum breaking force Fmin 1770 [kN] 2413
Minimum breaking force Fmin 1960 [kN] 2672
Minimum breaking force Fmin 2160 [kN] 2910
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 56
Minimum breaking force Fmin 1770 [kN] 2519
Minimum breaking force Fmin 1960 [kN] 2791
Minimum breaking force Fmin 2160 [kN] 3039
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 57
Minimum breaking force Fmin 1770 [kN] 2592
Minimum breaking force Fmin 1960 [kN] 2870
Minimum breaking force Fmin 2160 [kN] 3125
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 58
Minimum breaking force Fmin 1770 [kN] 2703
Minimum breaking force Fmin 1960 [kN] 2993
Minimum breaking force Fmin 2160 [kN] 3260
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 59
Minimum breaking force Fmin 1770 [kN] 2776
Minimum breaking force Fmin 1960 [kN] 3074
Minimum breaking force Fmin 2160 [kN] 3348
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 60
Minimum breaking force Fmin 1770 [kN] 2893
Minimum breaking force Fmin 1960 [kN] 3203
Minimum breaking force Fmin 2160 [kN] 3489
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 61
Minimum breaking force Fmin 1770 [kN] 2968
Minimum breaking force Fmin 1960 [kN] 3286
Minimum breaking force Fmin 2160 [kN] 3579
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 62
Minimum breaking force Fmin 1770 [kN] 3089
Minimum breaking force Fmin 1960 [kN] 3420
Minimum breaking force Fmin 2160 [kN] 3725
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 63
Minimum breaking force Fmin 1770 [kN] 3165
Minimum breaking force Fmin 1960 [kN] 3505
Minimum breaking force Fmin 2160 [kN] 3818
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 64
Minimum breaking force Fmin 1770 [kN] 3291
Minimum breaking force Fmin 1960 [kN] 3645
Minimum breaking force Fmin 2160 [kN] 3969
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 65
Minimum breaking force Fmin 1770 [kN] 3370
Minimum breaking force Fmin 1960 [kN] 3732
Minimum breaking force Fmin 2160 [kN] 4064
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 66
Minimum breaking force Fmin 1770 [kN] 3500
Minimum breaking force Fmin 1960 [kN] 3876
Minimum breaking force Fmin 2160 [kN] 4221
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 67
Minimum breaking force Fmin 1770 [kN] 3580
Minimum breaking force Fmin 1960 [kN] 3964
Minimum breaking force Fmin 2160 [kN] 4318
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 68
Minimum breaking force Fmin 1770 [kN] 3715
Minimum breaking force Fmin 1960 [kN] 4114
Minimum breaking force Fmin 2160 [kN] 4481
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 69
Minimum breaking force Fmin 1770 [kN] 3798
Minimum breaking force Fmin 1960 [kN] 4205
Minimum breaking force Fmin 2160 [kN] 4580
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 70
Minimum breaking force Fmin 1770 [kN] 3937
Minimum breaking force Fmin 1960 [kN] 4360
Minimum breaking force Fmin 2160 [kN] 4749
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 71
Minimum breaking force Fmin 1770 [kN] 4021
Minimum breaking force Fmin 1960 [kN] 4452
Minimum breaking force Fmin 2160 [kN] 4849
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 72
Minimum breaking force Fmin 1770 [kN] 4134
Minimum breaking force Fmin 1960 [kN] 4579
Minimum breaking force Fmin 2160 [kN] 4986
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 73
Minimum breaking force Fmin 1770 [kN] 4251
Minimum breaking force Fmin 1960 [kN] 4706
Minimum breaking force Fmin 2160 [kN] 5126
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 74
Minimum breaking force Fmin 1770 [kN] 4367
Minimum breaking force Fmin 1960 [kN] 4837
Minimum breaking force Fmin 2160 [kN] 5268
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 75
Minimum breaking force Fmin 1770 [kN] 4486
Minimum breaking force Fmin 1960 [kN] 4968
Minimum breaking force Fmin 2160 [kN] 5410
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 76
Minimum breaking force Fmin 1770 [kN] 4607
Minimum breaking force Fmin 1960 [kN] 5102
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 77
Minimum breaking force Fmin 1770 [kN] 4729
Minimum breaking force Fmin 1960 [kN] 5237
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 78
Minimum breaking force Fmin 1770 [kN] 4853
Minimum breaking force Fmin 1960 [kN] 5374
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 79
Minimum breaking force Fmin 1770 [kN] 4978
Minimum breaking force Fmin 1960 [kN] 5512
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 80
Minimum breaking force Fmin 1770 [kN] 5104
Minimum breaking force Fmin 1960 [kN] 5653
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 81
Minimum breaking force Fmin 1770 [kN] 5233
Minimum breaking force Fmin 1960 [kN] 5794
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 82
Minimum breaking force Fmin 1770 [kN] 5364
Minimum breaking force Fmin 1960 [kN] 5939
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 83
Minimum breaking force Fmin 1770 [kN] 5494
Minimum breaking force Fmin 1960 [kN] 6084
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 84
Minimum breaking force Fmin 1770 [kN] 5628
Minimum breaking force Fmin 1960 [kN] 6232
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 85
Minimum breaking force Fmin 1770 [kN] 5763
Minimum breaking force Fmin 1960 [kN] 6381
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 86
Minimum breaking force Fmin 1770 [kN] 5899
Minimum breaking force Fmin 1960 [kN] 6532
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 87
Minimum breaking force Fmin 1770 [kN] 6037
Minimum breaking force Fmin 1960 [kN] 6685
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 88
Minimum breaking force Fmin 1770 [kN] 6177
Minimum breaking force Fmin 1960 [kN] 6840
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 89
Minimum breaking force Fmin 1770 [kN] 6318
Minimum breaking force Fmin 1960 [kN] 6996
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 90
Minimum breaking force Fmin 1770 [kN] 6461
Minimum breaking force Fmin 1960 [kN] 7154
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 91
Minimum breaking force Fmin 1770 [kN] 6605
Minimum breaking force Fmin 1960 [kN] 7314
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 92
Minimum breaking force Fmin 1770 [kN] 6751
Minimum breaking force Fmin 1960 [kN] 7476
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 93
Minimum breaking force Fmin 1770 [kN] 6899
Minimum breaking force Fmin 1960 [kN] 7639
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 94
Minimum breaking force Fmin 1770 [kN] 7047
Minimum breaking force Fmin 1960 [kN] 7804
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 95
Minimum breaking force Fmin 1770 [kN] 7199
Minimum breaking force Fmin 1960 [kN] 7971
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 96
Minimum breaking force Fmin 1770 [kN] 7351
Minimum breaking force Fmin 1960 [kN] 8140
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 97
Minimum breaking force Fmin 1770 [kN] 7505
Minimum breaking force Fmin 1960 [kN] 8310
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 98
Minimum breaking force Fmin 1770 [kN] 7660
Minimum breaking force Fmin 1960 [kN] 8482
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 99
Minimum breaking force Fmin 1770 [kN] 7817
Minimum breaking force Fmin 1960 [kN] 8656
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Nominal rope Ø 100
Minimum breaking force Fmin 1770 [kN] 7976
Minimum breaking force Fmin 1960 [kN] 8832
  • Details
    Nominal rope Ø 100
    Weight approx. 4718 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 7976
    Minimum breaking force Fmin 1960 [kN] 8832
    Number of load-bearing wires in the external strands 328
    RCN according to ISO 4309 13
Other rope diameters and constructions on enquiry.
Downloads
Contact
Market Contact Location type
All other markets
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-301
Fax +49 8331 937-123
E-Mail wireropes@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Germany
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-181
Fax +49 8331 937-123
E-Mail seile@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Oktjaborskaja Nabereschnaja, No. 104, Korpus 23
RU-193079 St. Petersburg
Tel. +7 812 740 12-24
Fax +7 812 493 48-21
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Service centre
USA
PFEIFER Wire Rope & Lifting Technology Inc.
2023 Humble Westfield
US-Houston, TX 77037
Tel. +1 832 827 2923
Fax +1 281 784 2903
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Service centre
Austria
PFEIFER Seil- und Hebetechnik GmbH
Harterfeldweg 2
AT-4481 Asten
Tel. +43 7224 662 24-0
Fax +43 7224 662 24-13
E-Mail info@pfeifer-austria.at
Web www.pfeifer-austria.at
Sales subsidiary
China
PFEIFER Steel Wire Rope (Shanghai) Co., Ltd.
Building 1, No. 366 Chen Xiang Road, Nanxiang Town, Jiading District
CN-Shanghai 201802
Industrieseile/Industry ropes
Tel. +86 21 56 77 80 06
Fax +86 21 56 77 92 29
E-Mail info@pfeifer.com.cn
Web www.pfeifer.com.cn
Sales subsidiary
Great Britain
PFEIFER Rope & Tackle Ltd.
Unit 1A1, Marchwood Industrial Park, North Road
GB-Southampton SO40 4BL
Tel. +44 23 8066-5470
Fax +44 23 8066-5471
E-Mail sales@ropeandtackle.com
Web www.pfeifer-rt.com
Sales subsidiary
Hungary
PFEIFER Garant Kft.
Gyömrői út 108-126
HU-1103 Budapest
Tel. +36 1 260 10 14
Fax +36 1 262 09 27
E-Mail info@pfeifer-garant.hu
Web www.pfeifer-garant.hu
Sales subsidiary
Luxemburg
PFEIFER SOGEQUIP S.à.r.l.
Zone Ind. Schifflange-Foetz
LU-3844 Schifflange
Tel. +352 57 42-42
Fax +352 57 42-62
E-Mail info@pfeifer-sogequip.lu
Web www.pfeifer-sogequip.lu
Sales subsidiary
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Pyzhevskiy pereulok, h. 5, bld.1, office 108
RU-119017 Moskau
Tel. +7 495 363 01-27
Fax +7 495 363 01-28
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Sales subsidiary
Spain
PFEIFER Cables y Equipos de Elevación S.L.
Avda. de los Pirineos, 25 – Nave 20, San Sebastián de los Reyes
ES-28703 Madrid
Tel. +34 91 659-3185
Fax +34 91 659-3139
E-Mail p-es@pfeifer.es
Web www.pfeifer.es
Sales subsidiary
USA
PFEIFER Wire Rope & Lifting Technology Inc.
600 Industry Drive
US-Hampton, VA 23661
Tel. +1 757 825 2544
Fax +1 757 825 2546
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Sales subsidiary
United Arab Emirates
PFEIFER Middle East Wire Rope & Lifting Technology FZE
Jebel Ali Free Zone 1, RA08UA07, PO Box 263081
AE-Dubai
Tel. +971 4 883-8445
Fax +971 4 883-8446
E-Mail sales@pfeifer.ae
Web rope-lifting-ae.pfeifer.info
Sales subsidiary
Germany
PFEIFER Seil- und Hebetechnik GmbH
Krönenbarg 92b
DE-21077 Hamburg
Tel. +49 40 78 04 63-0
Fax +49 40 78 70 13
E-Mail psh-hamburg@pfeifer.de
Web www.pfeifer.info
Office
Switzerland
pewag Suisse AG
Hasentalstrasse 8
CH-8934 Knonau
Tel. +41 44 768 55-55
Fax +41 44 768 55-30
E-Mail info@pewag-suisse.ch
Web www.pewag-suisse.ch
Agency

Feel free to contact us

Tel.

+49 8331 937-301

Inquiry

please leave empty!
* Required fields

Cookie settings

We use cookies to optimise our web page for you. By continuing to use the web page you agree to the use of cookies. Further information about cookies can be found in our data protection declaration.

Required cookies

Required cookies are mandatory for the basic functions of the website. Without these cookies, you will unfortunately not be able to use our website. These cookies are always set when you use the website. No personal data is collected or stored.

Functional cookies

These cookies allow us to analyze website usage so that we can measure and improve its performance. No personal data is collected or stored.

Data protection declaration