PN 42/7

PN 42/7
technical infos

Average fill factor

  • 0.55

Core

  • steel core

Lay direction

  • Right hand

Compacting

  • not compacted

Finish

  • galvanized

nominal metallic cross-sectional area factor C

  • 0.432

Indication

  • Please refer to our operating manual stranded ropes! Available at www.pfeifer.info/manual-strand-ropes

  • Sample schematic of rope construction used for representative purposes only. Actual construction dependent upon rope diameter.
Safety

WARNING: Never use with a swivel – failure to comply may result in serious damages and injuries!
Product variants
Nominal rope Ø [mm]
Minimum breaking force Fmin 1770 [kN]
Minimum breaking force Fmin 1960 [kN]
Details
  • 2
    2.54
    2.81
    Nominal rope Ø 2
    Weight approx. 1.54 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2.54
    Minimum breaking force Fmin 1960 [kN] 2.81
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 2.5
    4
    4.4
    Nominal rope Ø 2.5
    Weight approx. 2.4 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4
    Minimum breaking force Fmin 1960 [kN] 4.4
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 3
    5.72
    6.33
    Nominal rope Ø 3
    Weight approx. 3.46 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 5.72
    Minimum breaking force Fmin 1960 [kN] 6.33
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 4
    10.2
    11.3
    Nominal rope Ø 4
    Weight approx. 6.14 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 10.2
    Minimum breaking force Fmin 1960 [kN] 11.3
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 5
    15.9
    17.6
    Nominal rope Ø 5
    Weight approx. 9.6 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 15.9
    Minimum breaking force Fmin 1960 [kN] 17.6
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 6
    22.9
    25.3
    Nominal rope Ø 6
    Weight approx. 13.8 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 22.9
    Minimum breaking force Fmin 1960 [kN] 25.3
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 7
    31.1
    34.5
    Nominal rope Ø 7
    Weight approx. 18.8 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 31.1
    Minimum breaking force Fmin 1960 [kN] 34.5
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 8
    40.7
    45
    Nominal rope Ø 8
    Weight approx. 24.6 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 40.7
    Minimum breaking force Fmin 1960 [kN] 45
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 9
    51.5
    57
    Nominal rope Ø 9
    Weight approx. 31.1 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 51.5
    Minimum breaking force Fmin 1960 [kN] 57
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 10
    63.5
    70.4
    Nominal rope Ø 10
    Weight approx. 38.4 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 63.5
    Minimum breaking force Fmin 1960 [kN] 70.4
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 11
    76.9
    85.1
    Nominal rope Ø 11
    Weight approx. 46.5 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 76.9
    Minimum breaking force Fmin 1960 [kN] 85.1
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 12
    91.5
    101
    Nominal rope Ø 12
    Weight approx. 55.3 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 91.5
    Minimum breaking force Fmin 1960 [kN] 101
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 13
    107
    119
    Nominal rope Ø 13
    Weight approx. 64.9 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 107
    Minimum breaking force Fmin 1960 [kN] 119
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 14
    125
    138
    Nominal rope Ø 14
    Weight approx. 75.3 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 125
    Minimum breaking force Fmin 1960 [kN] 138
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 16
    163
    180
    Nominal rope Ø 16
    Weight approx. 98.3 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 163
    Minimum breaking force Fmin 1960 [kN] 180
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 18
    206
    228
    Nominal rope Ø 18
    Weight approx. 124 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 206
    Minimum breaking force Fmin 1960 [kN] 228
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 20
    254
    281
    Nominal rope Ø 20
    Weight approx. 154 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 254
    Minimum breaking force Fmin 1960 [kN] 281
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 22
    308
    341
    Nominal rope Ø 22
    Weight approx. 186 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 308
    Minimum breaking force Fmin 1960 [kN] 341
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 24
    366
    405
    Nominal rope Ø 24
    Weight approx. 221 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 366
    Minimum breaking force Fmin 1960 [kN] 405
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 26
    430
    476
    Nominal rope Ø 26
    Weight approx. 260 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 430
    Minimum breaking force Fmin 1960 [kN] 476
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 28
    498
    552
    Nominal rope Ø 28
    Weight approx. 301 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 498
    Minimum breaking force Fmin 1960 [kN] 552
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 32
    651
    721
    Nominal rope Ø 32
    Weight approx. 393 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 651
    Minimum breaking force Fmin 1960 [kN] 721
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 36
    824
    912
    Nominal rope Ø 36
    Weight approx. 498 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 824
    Minimum breaking force Fmin 1960 [kN] 912
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
  • 40
    1020
    1130
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 2
Minimum breaking force Fmin 1770 [kN] 2.54
Minimum breaking force Fmin 1960 [kN] 2.81
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 2.5
Minimum breaking force Fmin 1770 [kN] 4
Minimum breaking force Fmin 1960 [kN] 4.4
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 3
Minimum breaking force Fmin 1770 [kN] 5.72
Minimum breaking force Fmin 1960 [kN] 6.33
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 4
Minimum breaking force Fmin 1770 [kN] 10.2
Minimum breaking force Fmin 1960 [kN] 11.3
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 5
Minimum breaking force Fmin 1770 [kN] 15.9
Minimum breaking force Fmin 1960 [kN] 17.6
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 6
Minimum breaking force Fmin 1770 [kN] 22.9
Minimum breaking force Fmin 1960 [kN] 25.3
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 7
Minimum breaking force Fmin 1770 [kN] 31.1
Minimum breaking force Fmin 1960 [kN] 34.5
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 8
Minimum breaking force Fmin 1770 [kN] 40.7
Minimum breaking force Fmin 1960 [kN] 45
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 9
Minimum breaking force Fmin 1770 [kN] 51.5
Minimum breaking force Fmin 1960 [kN] 57
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 10
Minimum breaking force Fmin 1770 [kN] 63.5
Minimum breaking force Fmin 1960 [kN] 70.4
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 11
Minimum breaking force Fmin 1770 [kN] 76.9
Minimum breaking force Fmin 1960 [kN] 85.1
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 12
Minimum breaking force Fmin 1770 [kN] 91.5
Minimum breaking force Fmin 1960 [kN] 101
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 13
Minimum breaking force Fmin 1770 [kN] 107
Minimum breaking force Fmin 1960 [kN] 119
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 14
Minimum breaking force Fmin 1770 [kN] 125
Minimum breaking force Fmin 1960 [kN] 138
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 16
Minimum breaking force Fmin 1770 [kN] 163
Minimum breaking force Fmin 1960 [kN] 180
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 18
Minimum breaking force Fmin 1770 [kN] 206
Minimum breaking force Fmin 1960 [kN] 228
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 20
Minimum breaking force Fmin 1770 [kN] 254
Minimum breaking force Fmin 1960 [kN] 281
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 22
Minimum breaking force Fmin 1770 [kN] 308
Minimum breaking force Fmin 1960 [kN] 341
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 24
Minimum breaking force Fmin 1770 [kN] 366
Minimum breaking force Fmin 1960 [kN] 405
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 26
Minimum breaking force Fmin 1770 [kN] 430
Minimum breaking force Fmin 1960 [kN] 476
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 28
Minimum breaking force Fmin 1770 [kN] 498
Minimum breaking force Fmin 1960 [kN] 552
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 32
Minimum breaking force Fmin 1770 [kN] 651
Minimum breaking force Fmin 1960 [kN] 721
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 36
Minimum breaking force Fmin 1770 [kN] 824
Minimum breaking force Fmin 1960 [kN] 912
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Nominal rope Ø 40
Minimum breaking force Fmin 1770 [kN] 1020
Minimum breaking force Fmin 1960 [kN] 1130
  • Details
    Nominal rope Ø 40
    Weight approx. 614 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1020
    Minimum breaking force Fmin 1960 [kN] 1130
    Number of load-bearing wires in the external strands 42
    RCN according to ISO 4309 01
Other rope diameters and constructions on enquiry.
Downloads
Contact
Market Contact Location type
All other markets
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-301
Fax +49 8331 937-123
E-Mail wireropes@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Germany
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-181
Fax +49 8331 937-123
E-Mail seile@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Oktjaborskaja Nabereschnaja, No. 104, Korpus 23
RU-193079 St. Petersburg
Tel. +7 812 740 12-24
Fax +7 812 493 48-21
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Service centre
USA
PFEIFER Wire Rope & Lifting Technology Inc.
2023 Humble Westfield
US-Houston, TX 77037
Tel. +1 832 827 2923
Fax +1 281 784 2903
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Service centre
Austria
PFEIFER Seil- und Hebetechnik GmbH
Harterfeldweg 2
AT-4481 Asten
Tel. +43 7224 662 24-0
Fax +43 7224 662 24-13
E-Mail info@pfeifer-austria.at
Web www.pfeifer-austria.at
Sales subsidiary
China
PFEIFER Steel Wire Rope (Shanghai) Co., Ltd.
Building 1, No. 366 Chen Xiang Road, Nanxiang Town, Jiading District
CN-Shanghai 201802
Industrieseile/Industry ropes
Tel. +86 21 56 77 80 06
Fax +86 21 56 77 92 29
E-Mail info@pfeifer.com.cn
Web www.pfeifer.com.cn
Sales subsidiary
Great Britain
PFEIFER Rope & Tackle Ltd.
Unit 1A1, Marchwood Industrial Park, North Road
GB-Southampton SO40 4BL
Tel. +44 23 8066-5470
Fax +44 23 8066-5471
E-Mail sales@ropeandtackle.com
Web www.pfeifer-rt.com
Sales subsidiary
Hungary
PFEIFER Garant Kft.
Gyömrői út 108-126
HU-1103 Budapest
Tel. +36 1 260 10 14
Fax +36 1 262 09 27
E-Mail info@pfeifer-garant.hu
Web www.pfeifer-garant.hu
Sales subsidiary
Luxemburg
PFEIFER SOGEQUIP S.à.r.l.
Zone Ind. Schifflange-Foetz
LU-3844 Schifflange
Tel. +352 57 42-42
Fax +352 57 42-62
E-Mail info@pfeifer-sogequip.lu
Web www.pfeifer-sogequip.lu
Sales subsidiary
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Pyzhevskiy pereulok, h. 5, bld.1, office 108
RU-119017 Moskau
Tel. +7 495 363 01-27
Fax +7 495 363 01-28
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Sales subsidiary
Spain
PFEIFER Cables y Equipos de Elevación S.L.
Avda. de los Pirineos, 25 – Nave 20, San Sebastián de los Reyes
ES-28703 Madrid
Tel. +34 91 659-3185
Fax +34 91 659-3139
E-Mail p-es@pfeifer.es
Web www.pfeifer.es
Sales subsidiary
USA
PFEIFER Wire Rope & Lifting Technology Inc.
600 Industry Drive
US-Hampton, VA 23661
Tel. +1 757 825 2544
Fax +1 757 825 2546
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Sales subsidiary
United Arab Emirates
PFEIFER Middle East Wire Rope & Lifting Technology FZE
Jebel Ali Free Zone 1, RA08UA07, PO Box 263081
AE-Dubai
Tel. +971 4 883-8445
Fax +971 4 883-8446
E-Mail sales@pfeifer.ae
Web rope-lifting-ae.pfeifer.info
Sales subsidiary
Germany
PFEIFER Seil- und Hebetechnik GmbH
Krönenbarg 92b
DE-21077 Hamburg
Tel. +49 40 78 04 63-0
Fax +49 40 78 70 13
E-Mail psh-hamburg@pfeifer.de
Web www.pfeifer.info
Office
Switzerland
pewag Suisse AG
Hasentalstrasse 8
CH-8934 Knonau
Tel. +41 44 768 55-55
Fax +41 44 768 55-30
E-Mail info@pewag-suisse.ch
Web www.pewag-suisse.ch
Agency

Feel free to contact us

Tel.

+49 8331 937-301

Inquiry

please leave empty!
* Required fields

Cookie settings

We use cookies to optimise our web page for you. By continuing to use the web page you agree to the use of cookies. Further information about cookies can be found in our data protection declaration.

Required cookies

Required cookies are mandatory for the basic functions of the website. Without these cookies, you will unfortunately not be able to use our website. These cookies are always set when you use the website. No personal data is collected or stored.

Functional cookies

These cookies allow us to analyze website usage so that we can measure and improve its performance. No personal data is collected or stored.

Data protection declaration