6x36WS-FC

6x36WS-FC
technical infos

Average fill factor

  • 0.5

Core

  • fibre core

Lay direction

  • Right hand

Compacting

  • not compacted

Finish

  • choice of bright or galvanised

nominal metallic cross-sectional area factor C

  • 0.393

Indication

  • Please refer to our operating manual stranded ropes! Available at www.pfeifer.info/manual-strand-ropes

  • Sample schematic of rope construction used for representative purposes only. Actual construction dependent upon rope diameter.
Product variants
Nominal rope Ø [mm]
Minimum breaking force Fmin 1770 [kN]
Minimum breaking force Fmin 1960 [kN]
Details
  • 8
    40.3
    44.7
    Nominal rope Ø [mm] 8
    Weight approx. 26.2 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 40.3
    Minimum breaking force Fmin 1960 [kN] 44.7
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 9
    47.3
    56.5
    Nominal rope Ø [mm] 9
    Weight approx. 33.1 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 47.3
    Minimum breaking force Fmin 1960 [kN] 56.5
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 10
    58.4
    69.8
    Nominal rope Ø [mm] 10
    Weight approx. 40.9 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 58.4
    Minimum breaking force Fmin 1960 [kN] 69.8
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 11
    70.7
    84.4
    Nominal rope Ø [mm] 11
    Weight approx. 49.5 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 70.7
    Minimum breaking force Fmin 1960 [kN] 84.4
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 12
    84.1
    100
    Nominal rope Ø [mm] 12
    Weight approx. 58.9 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 84.1
    Minimum breaking force Fmin 1960 [kN] 100
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 13
    98.7
    118
    Nominal rope Ø [mm] 13
    Weight approx. 69.1 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 98.7
    Minimum breaking force Fmin 1960 [kN] 118
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 14
    114
    137
    Nominal rope Ø [mm] 14
    Weight approx. 80.2 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 114
    Minimum breaking force Fmin 1960 [kN] 137
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 16
    150
    179
    Nominal rope Ø [mm] 16
    Weight approx. 105 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 150
    Minimum breaking force Fmin 1960 [kN] 179
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 18
    189
    226
    Nominal rope Ø [mm] 18
    Weight approx. 133 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 189
    Minimum breaking force Fmin 1960 [kN] 226
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 20
    234
    279
    Nominal rope Ø [mm] 20
    Weight approx. 164 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 234
    Minimum breaking force Fmin 1960 [kN] 279
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 22
    283
    338
    Nominal rope Ø [mm] 22
    Weight approx. 198 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 283
    Minimum breaking force Fmin 1960 [kN] 338
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 24
    336
    402
    Nominal rope Ø [mm] 24
    Weight approx. 236 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 336
    Minimum breaking force Fmin 1960 [kN] 402
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 26
    395
    472
    Nominal rope Ø [mm] 26
    Weight approx. 276 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 395
    Minimum breaking force Fmin 1960 [kN] 472
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 28
    458
    547
    Nominal rope Ø [mm] 28
    Weight approx. 321 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 458
    Minimum breaking force Fmin 1960 [kN] 547
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 32
    598
    715
    Nominal rope Ø [mm] 32
    Weight approx. 419 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 598
    Minimum breaking force Fmin 1960 [kN] 715
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 36
    757
    904
    Nominal rope Ø [mm] 36
    Weight approx. 530 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 757
    Minimum breaking force Fmin 1960 [kN] 904
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 40
    935
    1120
    Nominal rope Ø [mm] 40
    Weight approx. 654 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 935
    Minimum breaking force Fmin 1960 [kN] 1120
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 48
    1350
    1610
    Nominal rope Ø [mm] 48
    Weight approx. 942 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1350
    Minimum breaking force Fmin 1960 [kN] 1610
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 52
    1580
    1890
    Nominal rope Ø [mm] 52
    Weight approx. 1110 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1580
    Minimum breaking force Fmin 1960 [kN] 1890
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 56
    1830
    2190
    Nominal rope Ø [mm] 56
    Weight approx. 1280 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1830
    Minimum breaking force Fmin 1960 [kN] 2190
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
  • 60
    2100
    2510
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 8
Minimum breaking force Fmin 1770 [kN] 40.3
Minimum breaking force Fmin 1960 [kN] 44.7
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 9
Minimum breaking force Fmin 1770 [kN] 47.3
Minimum breaking force Fmin 1960 [kN] 56.5
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 10
Minimum breaking force Fmin 1770 [kN] 58.4
Minimum breaking force Fmin 1960 [kN] 69.8
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 11
Minimum breaking force Fmin 1770 [kN] 70.7
Minimum breaking force Fmin 1960 [kN] 84.4
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 12
Minimum breaking force Fmin 1770 [kN] 84.1
Minimum breaking force Fmin 1960 [kN] 100
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 13
Minimum breaking force Fmin 1770 [kN] 98.7
Minimum breaking force Fmin 1960 [kN] 118
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 14
Minimum breaking force Fmin 1770 [kN] 114
Minimum breaking force Fmin 1960 [kN] 137
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 16
Minimum breaking force Fmin 1770 [kN] 150
Minimum breaking force Fmin 1960 [kN] 179
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 18
Minimum breaking force Fmin 1770 [kN] 189
Minimum breaking force Fmin 1960 [kN] 226
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 20
Minimum breaking force Fmin 1770 [kN] 234
Minimum breaking force Fmin 1960 [kN] 279
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 22
Minimum breaking force Fmin 1770 [kN] 283
Minimum breaking force Fmin 1960 [kN] 338
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 24
Minimum breaking force Fmin 1770 [kN] 336
Minimum breaking force Fmin 1960 [kN] 402
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 26
Minimum breaking force Fmin 1770 [kN] 395
Minimum breaking force Fmin 1960 [kN] 472
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 28
Minimum breaking force Fmin 1770 [kN] 458
Minimum breaking force Fmin 1960 [kN] 547
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 32
Minimum breaking force Fmin 1770 [kN] 598
Minimum breaking force Fmin 1960 [kN] 715
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 36
Minimum breaking force Fmin 1770 [kN] 757
Minimum breaking force Fmin 1960 [kN] 904
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 40
Minimum breaking force Fmin 1770 [kN] 935
Minimum breaking force Fmin 1960 [kN] 1120
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 48
Minimum breaking force Fmin 1770 [kN] 1350
Minimum breaking force Fmin 1960 [kN] 1610
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 52
Minimum breaking force Fmin 1770 [kN] 1580
Minimum breaking force Fmin 1960 [kN] 1890
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 56
Minimum breaking force Fmin 1770 [kN] 1830
Minimum breaking force Fmin 1960 [kN] 2190
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Nominal rope Ø [mm] 60
Minimum breaking force Fmin 1770 [kN] 2100
Minimum breaking force Fmin 1960 [kN] 2510
  • Details
    Nominal rope Ø [mm] 60
    Weight approx. 1470 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2100
    Minimum breaking force Fmin 1960 [kN] 2510
    Number of load-bearing wires in the external strands 216
    RCN according to ISO 4309 09
Other rope diameters and constructions on enquiry.
Downloads
Contact
Market Contact Location type
All other markets
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-301
Fax +49 8331 937-123
E-Mail wireropes@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Germany
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-181
Fax +49 8331 937-123
E-Mail seile@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Oktjaborskaja Nabereschnaja, No. 104, Korpus 23
RU-193079 St. Petersburg
Tel. +7 812 740 12-24
Fax +7 812 493 48-21
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Service centre
USA
PFEIFER Wire Rope & Lifting Technology Inc.
2023 Humble Westfield
US-Houston, TX 77037
Tel. +1 832 827 2923
Fax +1 281 784 2903
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Service centre
Austria
PFEIFER Seil- und Hebetechnik GmbH
Harterfeldweg 2
AT-4481 Asten
Tel. +43 7224 662 24-0
Fax +43 7224 662 24-13
E-Mail info@pfeifer-austria.at
Web www.pfeifer-austria.at
Sales subsidiary
China
PFEIFER Steel Wire Rope (Shanghai) Co., Ltd.
Building 1, No. 366 Chen Xiang Road, Nanxiang Town, Jiading District
CN-Shanghai 201802
Industrieseile/Industry ropes
Tel. +86 21 56 77 80 06
Fax +86 21 56 77 92 29
E-Mail info@pfeifer.com.cn
Web www.pfeifer.com.cn
Sales subsidiary
Great Britain
PFEIFER Rope & Tackle Ltd.
Unit 1A1, Marchwood Industrial Park, North Road
GB-Southampton SO40 4BL
Tel. +44 23 8066-5470
Fax +44 23 8066-5471
E-Mail sales@ropeandtackle.com
Web www.pfeifer-rt.com
Sales subsidiary
Hungary
PFEIFER Garant Kft.
Gyömrői út 108-126
HU-1103 Budapest
Tel. +36 1 260 10 14
Fax +36 1 262 09 27
E-Mail info@pfeifer-garant.hu
Web www.pfeifer-garant.hu
Sales subsidiary
Luxemburg
PFEIFER SOGEQUIP S.à.r.l.
Zone Ind. Schifflange-Foetz
LU-3844 Schifflange
Tel. +352 57 42-42
Fax +352 57 42-62
E-Mail info@pfeifer-sogequip.lu
Web www.pfeifer-sogequip.lu
Sales subsidiary
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Pyzhevskiy pereulok, h. 5, bld.1, office 108
RU-119017 Moskau
Tel. +7 495 363 01-27
Fax +7 495 363 01-28
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Sales subsidiary
Spain
PFEIFER Cables y Equipos de Elevación S.L.
Avda. de los Pirineos, 25 – Nave 20, San Sebastián de los Reyes
ES-28703 Madrid
Tel. +34 91 659-3185
Fax +34 91 659-3139
E-Mail p-es@pfeifer.es
Web www.pfeifer.es
Sales subsidiary
USA
PFEIFER Wire Rope & Lifting Technology Inc.
600 Industry Drive
US-Hampton, VA 23661
Tel. +1 757 825 2544
Fax +1 757 825 2546
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Sales subsidiary
United Arab Emirates
PFEIFER Middle East Wire Rope & Lifting Technology FZE
Jebel Ali Free Zone 1, RA08UA07, PO Box 263081
AE-Dubai
Tel. +971 4 883-8445
Fax +971 4 883-8446
E-Mail sales@pfeifer.ae
Web rope-lifting-ae.pfeifer.info
Sales subsidiary
Germany
PFEIFER Seil- und Hebetechnik GmbH
Krönenbarg 92b
DE-21077 Hamburg
Tel. +49 40 78 04 63-0
Fax +49 40 78 70 13
E-Mail psh-hamburg@pfeifer.de
Web www.pfeifer.info
Office
Switzerland
pewag Suisse AG
Hasentalstrasse 8
CH-8934 Knonau
Tel. +41 44 768 55-55
Fax +41 44 768 55-30
E-Mail info@pewag-suisse.ch
Web www.pewag-suisse.ch
Agency

Feel free to contact us

Tel.

+49 8331 937-301

Inquiry

please leave empty!
* Required fields

Cookie settings

We use cookies to optimise our web page for you. By continuing to use the web page you agree to the use of cookies. Further information about cookies can be found in our data protection declaration.

Required cookies

Required cookies are mandatory for the basic functions of the website. Without these cookies, you will unfortunately not be able to use our website. These cookies are always set when you use the website. No personal data is collected or stored.

Functional cookies

These cookies allow us to analyze website usage so that we can measure and improve its performance. No personal data is collected or stored.

Data protection declaration