P 115

P 115
technical infos

Average fill factor

  • 0.7357

average spinning loss factor 1770

  • 0.845

average spinning loss factor 1960

  • 0.845

average spinning loss factor 2160

  • 0.825

Core

  • steel core compacted

Lay type

  • lang lay

Lay direction

  • choice of right hand or left hand

Compacting

  • strands compacted – thereby extra wear resistant

Finish

  • bright

Rope diameter tolerance

  • 0/+4%

Indication

  • Please refer to our operating manual stranded ropes! Available at www.pfeifer.info/manual-strand-ropes

  • Sample schematic of rope construction used for representative purposes only. Actual construction dependent upon rope diameter.
Product variants
Nominal rope Ø [mm]
Minimum breaking force Fmin 1770 [kN]
Minimum breaking force Fmin 1960 [kN]
Minimum breaking force Fmin 2160 [kN]
Details
  • 12
    123
    137
    148
    Nominal rope Ø [mm] 12
    Weight approx. 72 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 123
    Minimum breaking force Fmin 1960 [kN] 137
    Minimum breaking force Fmin 2160 [kN] 148
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 13
    147
    162
    175
    Nominal rope Ø [mm] 13
    Weight approx. 85 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 147
    Minimum breaking force Fmin 1960 [kN] 162
    Minimum breaking force Fmin 2160 [kN] 175
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 14
    169
    188
    202
    Nominal rope Ø [mm] 14
    Weight approx. 98 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 169
    Minimum breaking force Fmin 1960 [kN] 188
    Minimum breaking force Fmin 2160 [kN] 202
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 15
    194
    215
    232
    Nominal rope Ø [mm] 15
    Weight approx. 112 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 194
    Minimum breaking force Fmin 1960 [kN] 215
    Minimum breaking force Fmin 2160 [kN] 232
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 16
    223
    248
    266
    Nominal rope Ø [mm] 16
    Weight approx. 130 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 223
    Minimum breaking force Fmin 1960 [kN] 248
    Minimum breaking force Fmin 2160 [kN] 266
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 17
    250
    278
    299
    Nominal rope Ø [mm] 17
    Weight approx. 145 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 250
    Minimum breaking force Fmin 1960 [kN] 278
    Minimum breaking force Fmin 2160 [kN] 299
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 18
    281
    313
    337
    Nominal rope Ø [mm] 18
    Weight approx. 163 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 281
    Minimum breaking force Fmin 1960 [kN] 313
    Minimum breaking force Fmin 2160 [kN] 337
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 19
    312
    347
    373
    Nominal rope Ø [mm] 19
    Weight approx. 181 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 312
    Minimum breaking force Fmin 1960 [kN] 347
    Minimum breaking force Fmin 2160 [kN] 373
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 20
    347
    386
    416
    Nominal rope Ø [mm] 20
    Weight approx. 201 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 347
    Minimum breaking force Fmin 1960 [kN] 386
    Minimum breaking force Fmin 2160 [kN] 416
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 21
    386
    428
    461
    Nominal rope Ø [mm] 21
    Weight approx. 224 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 386
    Minimum breaking force Fmin 1960 [kN] 428
    Minimum breaking force Fmin 2160 [kN] 461
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 22
    422
    470
    505
    Nominal rope Ø [mm] 22
    Weight approx. 245 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 422
    Minimum breaking force Fmin 1960 [kN] 470
    Minimum breaking force Fmin 2160 [kN] 505
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 23
    460
    512
    550
    Nominal rope Ø [mm] 23
    Weight approx. 267 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 460
    Minimum breaking force Fmin 1960 [kN] 512
    Minimum breaking force Fmin 2160 [kN] 550
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 24
    500
    556
    598
    Nominal rope Ø [mm] 24
    Weight approx. 290 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 500
    Minimum breaking force Fmin 1960 [kN] 556
    Minimum breaking force Fmin 2160 [kN] 598
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 25
    532
    592
    637
    Nominal rope Ø [mm] 25
    Weight approx. 309 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 532
    Minimum breaking force Fmin 1960 [kN] 592
    Minimum breaking force Fmin 2160 [kN] 637
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 26
    577
    640
    689
    Nominal rope Ø [mm] 26
    Weight approx. 334 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 577
    Minimum breaking force Fmin 1960 [kN] 640
    Minimum breaking force Fmin 2160 [kN] 689
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 27
    620
    689
    740
    Nominal rope Ø [mm] 27
    Weight approx. 360 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 620
    Minimum breaking force Fmin 1960 [kN] 689
    Minimum breaking force Fmin 2160 [kN] 740
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 28
    678
    754
    811
    Nominal rope Ø [mm] 28
    Weight approx. 394 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 678
    Minimum breaking force Fmin 1960 [kN] 754
    Minimum breaking force Fmin 2160 [kN] 811
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 29
    719
    800
    860
    Nominal rope Ø [mm] 29
    Weight approx. 417 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 719
    Minimum breaking force Fmin 1960 [kN] 800
    Minimum breaking force Fmin 2160 [kN] 860
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 30
    770
    856
    919
    Nominal rope Ø [mm] 30
    Weight approx. 446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 770
    Minimum breaking force Fmin 1960 [kN] 856
    Minimum breaking force Fmin 2160 [kN] 919
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 31
    818
    909
    977
    Nominal rope Ø [mm] 31
    Weight approx. 474 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 818
    Minimum breaking force Fmin 1960 [kN] 909
    Minimum breaking force Fmin 2160 [kN] 977
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 32
    877
    975
    1048
    Nominal rope Ø [mm] 32
    Weight approx. 509 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 877
    Minimum breaking force Fmin 1960 [kN] 975
    Minimum breaking force Fmin 2160 [kN] 1048
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 33
    931
    1035
    1113
    Nominal rope Ø [mm] 33
    Weight approx. 540 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 931
    Minimum breaking force Fmin 1960 [kN] 1035
    Minimum breaking force Fmin 2160 [kN] 1113
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 34
    990
    1100
    1183
    Nominal rope Ø [mm] 34
    Weight approx. 575 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 990
    Minimum breaking force Fmin 1960 [kN] 1100
    Minimum breaking force Fmin 2160 [kN] 1183
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 35
    1054
    1171
    1258
    Nominal rope Ø [mm] 35
    Weight approx. 612 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1054
    Minimum breaking force Fmin 1960 [kN] 1171
    Minimum breaking force Fmin 2160 [kN] 1258
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 36
    1115
    1240
    1332
    Nominal rope Ø [mm] 36
    Weight approx. 647 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1115
    Minimum breaking force Fmin 1960 [kN] 1240
    Minimum breaking force Fmin 2160 [kN] 1332
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 37
    1178
    1309
    1406
    Nominal rope Ø [mm] 37
    Weight approx. 684 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1178
    Minimum breaking force Fmin 1960 [kN] 1309
    Minimum breaking force Fmin 2160 [kN] 1406
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 38
    1243
    1381
    1483
    Nominal rope Ø [mm] 38
    Weight approx. 721 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1243
    Minimum breaking force Fmin 1960 [kN] 1381
    Minimum breaking force Fmin 2160 [kN] 1483
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 39
    1309
    1455
    1562
    Nominal rope Ø [mm] 39
    Weight approx. 759 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1309
    Minimum breaking force Fmin 1960 [kN] 1455
    Minimum breaking force Fmin 2160 [kN] 1562
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 40
    1377
    1530
    1643
    Nominal rope Ø [mm] 40
    Weight approx. 799 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1377
    Minimum breaking force Fmin 1960 [kN] 1530
    Minimum breaking force Fmin 2160 [kN] 1643
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 41
    1446
    1608
    1727
    Nominal rope Ø [mm] 41
    Weight approx. 839 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1446
    Minimum breaking force Fmin 1960 [kN] 1608
    Minimum breaking force Fmin 2160 [kN] 1727
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 42
    1518
    1687
    1812
    Nominal rope Ø [mm] 42
    Weight approx. 880 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1518
    Minimum breaking force Fmin 1960 [kN] 1687
    Minimum breaking force Fmin 2160 [kN] 1812
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 43
    1591
    1769
    1899
    Nominal rope Ø [mm] 43
    Weight approx. 923 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1591
    Minimum breaking force Fmin 1960 [kN] 1769
    Minimum breaking force Fmin 2160 [kN] 1899
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 44
    1666
    1851
    1989
    Nominal rope Ø [mm] 44
    Weight approx. 966 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1666
    Minimum breaking force Fmin 1960 [kN] 1851
    Minimum breaking force Fmin 2160 [kN] 1989
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 45
    1743
    1936
    2080
    Nominal rope Ø [mm] 45
    Weight approx. 1011 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1743
    Minimum breaking force Fmin 1960 [kN] 1936
    Minimum breaking force Fmin 2160 [kN] 2080
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 46
    1821
    2023
    2173
    Nominal rope Ø [mm] 46
    Weight approx. 1056 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1821
    Minimum breaking force Fmin 1960 [kN] 2023
    Minimum breaking force Fmin 2160 [kN] 2173
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 47
    1901
    2113
    2269
    Nominal rope Ø [mm] 47
    Weight approx. 1102 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1901
    Minimum breaking force Fmin 1960 [kN] 2113
    Minimum breaking force Fmin 2160 [kN] 2269
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 48
    1983
    2203
    2366
    Nominal rope Ø [mm] 48
    Weight approx. 1149 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 1983
    Minimum breaking force Fmin 1960 [kN] 2203
    Minimum breaking force Fmin 2160 [kN] 2366
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 49
    2067
    2296
    2466
    Nominal rope Ø [mm] 49
    Weight approx. 1198 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2067
    Minimum breaking force Fmin 1960 [kN] 2296
    Minimum breaking force Fmin 2160 [kN] 2466
    Number of load-bearing wires in the external strands 105
    RCN according to ISO 4309 23-2
  • 50
    2152
    2391
    2567
    Nominal rope Ø [mm] 50
    Weight approx. 1248 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2152
    Minimum breaking force Fmin 1960 [kN] 2391
    Minimum breaking force Fmin 2160 [kN] 2567
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 51
    2239
    2488
    2672
    Nominal rope Ø [mm] 51
    Weight approx. 1298 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2239
    Minimum breaking force Fmin 1960 [kN] 2488
    Minimum breaking force Fmin 2160 [kN] 2672
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 52
    2327
    2586
    2778
    Nominal rope Ø [mm] 52
    Weight approx. 1350 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2327
    Minimum breaking force Fmin 1960 [kN] 2586
    Minimum breaking force Fmin 2160 [kN] 2778
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 53
    2417
    2687
    2885
    Nominal rope Ø [mm] 53
    Weight approx. 1402 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2417
    Minimum breaking force Fmin 1960 [kN] 2687
    Minimum breaking force Fmin 2160 [kN] 2885
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 54
    2510
    2788
    2995
    Nominal rope Ø [mm] 54
    Weight approx. 1455 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2510
    Minimum breaking force Fmin 1960 [kN] 2788
    Minimum breaking force Fmin 2160 [kN] 2995
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 55
    2603
    2893
    3107
    Nominal rope Ø [mm] 55
    Weight approx. 1509 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2603
    Minimum breaking force Fmin 1960 [kN] 2893
    Minimum breaking force Fmin 2160 [kN] 3107
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 56
    2699
    2999
    3221
    Nominal rope Ø [mm] 56
    Weight approx. 1565 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2699
    Minimum breaking force Fmin 1960 [kN] 2999
    Minimum breaking force Fmin 2160 [kN] 3221
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 57
    2803
    3105
    3340
    Nominal rope Ø [mm] 57
    Weight approx. 1621 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2803
    Minimum breaking force Fmin 1960 [kN] 3105
    Minimum breaking force Fmin 2160 [kN] 3340
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 58
    2902
    3214
    3459
    Nominal rope Ø [mm] 58
    Weight approx. 1679 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 2902
    Minimum breaking force Fmin 1960 [kN] 3214
    Minimum breaking force Fmin 2160 [kN] 3459
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 59
    3004
    3326
    3578
    Nominal rope Ø [mm] 59
    Weight approx. 1737 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3004
    Minimum breaking force Fmin 1960 [kN] 3326
    Minimum breaking force Fmin 2160 [kN] 3578
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 60
    3106
    3440
    3701
    Nominal rope Ø [mm] 60
    Weight approx. 1796 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3106
    Minimum breaking force Fmin 1960 [kN] 3440
    Minimum breaking force Fmin 2160 [kN] 3701
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 61
    3211
    3555
    3825
    Nominal rope Ø [mm] 61
    Weight approx. 1857 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3211
    Minimum breaking force Fmin 1960 [kN] 3555
    Minimum breaking force Fmin 2160 [kN] 3825
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 62
    3317
    3673
    3951
    Nominal rope Ø [mm] 62
    Weight approx. 1918 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3317
    Minimum breaking force Fmin 1960 [kN] 3673
    Minimum breaking force Fmin 2160 [kN] 3951
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 63
    3424
    3792
    4080
    Nominal rope Ø [mm] 63
    Weight approx. 1981 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3424
    Minimum breaking force Fmin 1960 [kN] 3792
    Minimum breaking force Fmin 2160 [kN] 4080
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 64
    3534
    3913
    4211
    Nominal rope Ø [mm] 64
    Weight approx. 2044 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3534
    Minimum breaking force Fmin 1960 [kN] 3913
    Minimum breaking force Fmin 2160 [kN] 4211
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 65
    3646
    4037
    4343
    Nominal rope Ø [mm] 65
    Weight approx. 2108 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3646
    Minimum breaking force Fmin 1960 [kN] 4037
    Minimum breaking force Fmin 2160 [kN] 4343
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 66
    3759
    4162
    4478
    Nominal rope Ø [mm] 66
    Weight approx. 2173 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3759
    Minimum breaking force Fmin 1960 [kN] 4162
    Minimum breaking force Fmin 2160 [kN] 4478
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 67
    3873
    4289
    4615
    Nominal rope Ø [mm] 67
    Weight approx. 2240 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3873
    Minimum breaking force Fmin 1960 [kN] 4289
    Minimum breaking force Fmin 2160 [kN] 4615
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 68
    3990
    4418
    4754
    Nominal rope Ø [mm] 68
    Weight approx. 2308 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 3990
    Minimum breaking force Fmin 1960 [kN] 4418
    Minimum breaking force Fmin 2160 [kN] 4754
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 69
    4108
    4549
    4894
    Nominal rope Ø [mm] 69
    Weight approx. 2376 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4108
    Minimum breaking force Fmin 1960 [kN] 4549
    Minimum breaking force Fmin 2160 [kN] 4894
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
  • 70
    4228
    4681
    5037
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 12
Minimum breaking force Fmin 1770 [kN] 123
Minimum breaking force Fmin 1960 [kN] 137
Minimum breaking force Fmin 2160 [kN] 148
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 13
Minimum breaking force Fmin 1770 [kN] 147
Minimum breaking force Fmin 1960 [kN] 162
Minimum breaking force Fmin 2160 [kN] 175
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 14
Minimum breaking force Fmin 1770 [kN] 169
Minimum breaking force Fmin 1960 [kN] 188
Minimum breaking force Fmin 2160 [kN] 202
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 15
Minimum breaking force Fmin 1770 [kN] 194
Minimum breaking force Fmin 1960 [kN] 215
Minimum breaking force Fmin 2160 [kN] 232
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 16
Minimum breaking force Fmin 1770 [kN] 223
Minimum breaking force Fmin 1960 [kN] 248
Minimum breaking force Fmin 2160 [kN] 266
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 17
Minimum breaking force Fmin 1770 [kN] 250
Minimum breaking force Fmin 1960 [kN] 278
Minimum breaking force Fmin 2160 [kN] 299
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 18
Minimum breaking force Fmin 1770 [kN] 281
Minimum breaking force Fmin 1960 [kN] 313
Minimum breaking force Fmin 2160 [kN] 337
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 19
Minimum breaking force Fmin 1770 [kN] 312
Minimum breaking force Fmin 1960 [kN] 347
Minimum breaking force Fmin 2160 [kN] 373
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 20
Minimum breaking force Fmin 1770 [kN] 347
Minimum breaking force Fmin 1960 [kN] 386
Minimum breaking force Fmin 2160 [kN] 416
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 21
Minimum breaking force Fmin 1770 [kN] 386
Minimum breaking force Fmin 1960 [kN] 428
Minimum breaking force Fmin 2160 [kN] 461
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 22
Minimum breaking force Fmin 1770 [kN] 422
Minimum breaking force Fmin 1960 [kN] 470
Minimum breaking force Fmin 2160 [kN] 505
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 23
Minimum breaking force Fmin 1770 [kN] 460
Minimum breaking force Fmin 1960 [kN] 512
Minimum breaking force Fmin 2160 [kN] 550
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 24
Minimum breaking force Fmin 1770 [kN] 500
Minimum breaking force Fmin 1960 [kN] 556
Minimum breaking force Fmin 2160 [kN] 598
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 25
Minimum breaking force Fmin 1770 [kN] 532
Minimum breaking force Fmin 1960 [kN] 592
Minimum breaking force Fmin 2160 [kN] 637
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 26
Minimum breaking force Fmin 1770 [kN] 577
Minimum breaking force Fmin 1960 [kN] 640
Minimum breaking force Fmin 2160 [kN] 689
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 27
Minimum breaking force Fmin 1770 [kN] 620
Minimum breaking force Fmin 1960 [kN] 689
Minimum breaking force Fmin 2160 [kN] 740
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 28
Minimum breaking force Fmin 1770 [kN] 678
Minimum breaking force Fmin 1960 [kN] 754
Minimum breaking force Fmin 2160 [kN] 811
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 29
Minimum breaking force Fmin 1770 [kN] 719
Minimum breaking force Fmin 1960 [kN] 800
Minimum breaking force Fmin 2160 [kN] 860
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 30
Minimum breaking force Fmin 1770 [kN] 770
Minimum breaking force Fmin 1960 [kN] 856
Minimum breaking force Fmin 2160 [kN] 919
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 31
Minimum breaking force Fmin 1770 [kN] 818
Minimum breaking force Fmin 1960 [kN] 909
Minimum breaking force Fmin 2160 [kN] 977
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 32
Minimum breaking force Fmin 1770 [kN] 877
Minimum breaking force Fmin 1960 [kN] 975
Minimum breaking force Fmin 2160 [kN] 1048
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 33
Minimum breaking force Fmin 1770 [kN] 931
Minimum breaking force Fmin 1960 [kN] 1035
Minimum breaking force Fmin 2160 [kN] 1113
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 34
Minimum breaking force Fmin 1770 [kN] 990
Minimum breaking force Fmin 1960 [kN] 1100
Minimum breaking force Fmin 2160 [kN] 1183
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 35
Minimum breaking force Fmin 1770 [kN] 1054
Minimum breaking force Fmin 1960 [kN] 1171
Minimum breaking force Fmin 2160 [kN] 1258
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 36
Minimum breaking force Fmin 1770 [kN] 1115
Minimum breaking force Fmin 1960 [kN] 1240
Minimum breaking force Fmin 2160 [kN] 1332
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 37
Minimum breaking force Fmin 1770 [kN] 1178
Minimum breaking force Fmin 1960 [kN] 1309
Minimum breaking force Fmin 2160 [kN] 1406
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 38
Minimum breaking force Fmin 1770 [kN] 1243
Minimum breaking force Fmin 1960 [kN] 1381
Minimum breaking force Fmin 2160 [kN] 1483
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 39
Minimum breaking force Fmin 1770 [kN] 1309
Minimum breaking force Fmin 1960 [kN] 1455
Minimum breaking force Fmin 2160 [kN] 1562
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 40
Minimum breaking force Fmin 1770 [kN] 1377
Minimum breaking force Fmin 1960 [kN] 1530
Minimum breaking force Fmin 2160 [kN] 1643
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 41
Minimum breaking force Fmin 1770 [kN] 1446
Minimum breaking force Fmin 1960 [kN] 1608
Minimum breaking force Fmin 2160 [kN] 1727
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 42
Minimum breaking force Fmin 1770 [kN] 1518
Minimum breaking force Fmin 1960 [kN] 1687
Minimum breaking force Fmin 2160 [kN] 1812
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 43
Minimum breaking force Fmin 1770 [kN] 1591
Minimum breaking force Fmin 1960 [kN] 1769
Minimum breaking force Fmin 2160 [kN] 1899
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 44
Minimum breaking force Fmin 1770 [kN] 1666
Minimum breaking force Fmin 1960 [kN] 1851
Minimum breaking force Fmin 2160 [kN] 1989
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 45
Minimum breaking force Fmin 1770 [kN] 1743
Minimum breaking force Fmin 1960 [kN] 1936
Minimum breaking force Fmin 2160 [kN] 2080
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 46
Minimum breaking force Fmin 1770 [kN] 1821
Minimum breaking force Fmin 1960 [kN] 2023
Minimum breaking force Fmin 2160 [kN] 2173
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 47
Minimum breaking force Fmin 1770 [kN] 1901
Minimum breaking force Fmin 1960 [kN] 2113
Minimum breaking force Fmin 2160 [kN] 2269
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 48
Minimum breaking force Fmin 1770 [kN] 1983
Minimum breaking force Fmin 1960 [kN] 2203
Minimum breaking force Fmin 2160 [kN] 2366
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 49
Minimum breaking force Fmin 1770 [kN] 2067
Minimum breaking force Fmin 1960 [kN] 2296
Minimum breaking force Fmin 2160 [kN] 2466
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 50
Minimum breaking force Fmin 1770 [kN] 2152
Minimum breaking force Fmin 1960 [kN] 2391
Minimum breaking force Fmin 2160 [kN] 2567
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 51
Minimum breaking force Fmin 1770 [kN] 2239
Minimum breaking force Fmin 1960 [kN] 2488
Minimum breaking force Fmin 2160 [kN] 2672
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 52
Minimum breaking force Fmin 1770 [kN] 2327
Minimum breaking force Fmin 1960 [kN] 2586
Minimum breaking force Fmin 2160 [kN] 2778
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 53
Minimum breaking force Fmin 1770 [kN] 2417
Minimum breaking force Fmin 1960 [kN] 2687
Minimum breaking force Fmin 2160 [kN] 2885
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 54
Minimum breaking force Fmin 1770 [kN] 2510
Minimum breaking force Fmin 1960 [kN] 2788
Minimum breaking force Fmin 2160 [kN] 2995
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 55
Minimum breaking force Fmin 1770 [kN] 2603
Minimum breaking force Fmin 1960 [kN] 2893
Minimum breaking force Fmin 2160 [kN] 3107
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 56
Minimum breaking force Fmin 1770 [kN] 2699
Minimum breaking force Fmin 1960 [kN] 2999
Minimum breaking force Fmin 2160 [kN] 3221
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 57
Minimum breaking force Fmin 1770 [kN] 2803
Minimum breaking force Fmin 1960 [kN] 3105
Minimum breaking force Fmin 2160 [kN] 3340
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 58
Minimum breaking force Fmin 1770 [kN] 2902
Minimum breaking force Fmin 1960 [kN] 3214
Minimum breaking force Fmin 2160 [kN] 3459
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 59
Minimum breaking force Fmin 1770 [kN] 3004
Minimum breaking force Fmin 1960 [kN] 3326
Minimum breaking force Fmin 2160 [kN] 3578
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 60
Minimum breaking force Fmin 1770 [kN] 3106
Minimum breaking force Fmin 1960 [kN] 3440
Minimum breaking force Fmin 2160 [kN] 3701
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 61
Minimum breaking force Fmin 1770 [kN] 3211
Minimum breaking force Fmin 1960 [kN] 3555
Minimum breaking force Fmin 2160 [kN] 3825
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 62
Minimum breaking force Fmin 1770 [kN] 3317
Minimum breaking force Fmin 1960 [kN] 3673
Minimum breaking force Fmin 2160 [kN] 3951
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 63
Minimum breaking force Fmin 1770 [kN] 3424
Minimum breaking force Fmin 1960 [kN] 3792
Minimum breaking force Fmin 2160 [kN] 4080
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 64
Minimum breaking force Fmin 1770 [kN] 3534
Minimum breaking force Fmin 1960 [kN] 3913
Minimum breaking force Fmin 2160 [kN] 4211
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 65
Minimum breaking force Fmin 1770 [kN] 3646
Minimum breaking force Fmin 1960 [kN] 4037
Minimum breaking force Fmin 2160 [kN] 4343
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 66
Minimum breaking force Fmin 1770 [kN] 3759
Minimum breaking force Fmin 1960 [kN] 4162
Minimum breaking force Fmin 2160 [kN] 4478
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 67
Minimum breaking force Fmin 1770 [kN] 3873
Minimum breaking force Fmin 1960 [kN] 4289
Minimum breaking force Fmin 2160 [kN] 4615
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 68
Minimum breaking force Fmin 1770 [kN] 3990
Minimum breaking force Fmin 1960 [kN] 4418
Minimum breaking force Fmin 2160 [kN] 4754
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 69
Minimum breaking force Fmin 1770 [kN] 4108
Minimum breaking force Fmin 1960 [kN] 4549
Minimum breaking force Fmin 2160 [kN] 4894
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Nominal rope Ø [mm] 70
Minimum breaking force Fmin 1770 [kN] 4228
Minimum breaking force Fmin 1960 [kN] 4681
Minimum breaking force Fmin 2160 [kN] 5037
  • Details
    Nominal rope Ø [mm] 70
    Weight approx. 2446 [kg/100 m]
    Minimum breaking force Fmin 1770 [kN] 4228
    Minimum breaking force Fmin 1960 [kN] 4681
    Minimum breaking force Fmin 2160 [kN] 5037
    Number of load-bearing wires in the external strands 255
    RCN according to ISO 4309 27
Other rope diameters and constructions on enquiry.
Downloads
Contact
Market Contact Location type
All other markets
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-301
Fax +49 8331 937-123
E-Mail wireropes@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Germany
PFEIFER Seil- und Hebetechnik GmbH
Dr.-Karl-Lenz-Strasse 66
DE-87700 Memmingen
Tel. +49 8331 937-181
Fax +49 8331 937-123
E-Mail seile@pfeifer.de
Web www.pfeifer.info
Parent company/Head office
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Oktjaborskaja Nabereschnaja, No. 104, Korpus 23
RU-193079 St. Petersburg
Tel. +7 812 740 12-24
Fax +7 812 493 48-21
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Service centre
USA
PFEIFER Wire Rope & Lifting Technology Inc.
2023 Humble Westfield
US-Houston, TX 77037
Tel. +1 832 827 2923
Fax +1 281 784 2903
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Service centre
Austria
PFEIFER Seil- und Hebetechnik GmbH
Harterfeldweg 2
AT-4481 Asten
Tel. +43 7224 662 24-0
Fax +43 7224 662 24-13
E-Mail info@pfeifer-austria.at
Web www.pfeifer-austria.at
Sales subsidiary
China
PFEIFER Steel Wire Rope (Shanghai) Co., Ltd.
Building 1, No. 366 Chen Xiang Road, Nanxiang Town, Jiading District
CN-Shanghai 201802
Industrieseile/Industry ropes
Tel. +86 21 56 77 80 06
Fax +86 21 56 77 92 29
E-Mail info@pfeifer.com.cn
Web www.pfeifer.com.cn
Sales subsidiary
Great Britain
PFEIFER Rope & Tackle Ltd.
Unit 1A1, Marchwood Industrial Park, North Road
GB-Southampton SO40 4BL
Tel. +44 23 8066-5470
Fax +44 23 8066-5471
E-Mail sales@ropeandtackle.com
Web www.pfeifer-rt.com
Sales subsidiary
Hungary
PFEIFER Garant Kft.
Gyömrői út 108-126
HU-1103 Budapest
Tel. +36 1 260 10 14
Fax +36 1 262 09 27
E-Mail info@pfeifer-garant.hu
Web www.pfeifer-garant.hu
Sales subsidiary
Luxemburg
PFEIFER SOGEQUIP S.à.r.l.
Zone Ind. Schifflange-Foetz
LU-3844 Schifflange
Tel. +352 57 42-42
Fax +352 57 42-62
E-Mail info@pfeifer-sogequip.lu
Web www.pfeifer-sogequip.lu
Sales subsidiary
Russia
OOO PFEIFER Kanati & Podjömnie Tehnologii
Pyzhevskiy pereulok, h. 5, bld.1, office 108
RU-119017 Moskau
Tel. +7 495 363 01-27
Fax +7 495 363 01-28
E-Mail info@pfeiferrussia.ru
Web www.pfeiferrussia.ru
Sales subsidiary
Spain
PFEIFER Cables y Equipos de Elevación S.L.
Avda. de los Pirineos, 25 – Nave 20, San Sebastián de los Reyes
ES-28703 Madrid
Tel. +34 91 659-3185
Fax +34 91 659-3139
E-Mail p-es@pfeifer.es
Web www.pfeifer.es
Sales subsidiary
USA
PFEIFER Wire Rope & Lifting Technology Inc.
600 Industry Drive
US-Hampton, VA 23661
Tel. +1 757 825 2544
Fax +1 757 825 2546
E-Mail info@pfeifer.us.com
Web www.pfeifer.us.com
Sales subsidiary
United Arab Emirates
PFEIFER Middle East Wire Rope & Lifting Technology FZE
Jebel Ali Free Zone 1, RA08UA07, PO Box 263081
AE-Dubai
Tel. +971 4 883-8445
Fax +971 4 883-8446
E-Mail sales@pfeifer.ae
Web rope-lifting-ae.pfeifer.info
Sales subsidiary
Germany
PFEIFER Seil- und Hebetechnik GmbH
Krönenbarg 92b
DE-21077 Hamburg
Tel. +49 40 78 04 63-0
Fax +49 40 78 70 13
E-Mail psh-hamburg@pfeifer.de
Web www.pfeifer.info
Office
Switzerland
pewag Suisse AG
Hasentalstrasse 8
CH-8934 Knonau
Tel. +41 44 768 55-55
Fax +41 44 768 55-30
E-Mail info@pewag-suisse.ch
Web www.pewag-suisse.ch
Agency

Feel free to contact us

Tel.

+49 8331 937-301

Inquiry

please leave empty!
* Required fields

Cookie settings

We use cookies to optimise our web page for you. By continuing to use the web page you agree to the use of cookies. Further information about cookies can be found in our data protection declaration.

Required cookies

Required cookies are mandatory for the basic functions of the website. Without these cookies, you will unfortunately not be able to use our website. These cookies are always set when you use the website. No personal data is collected or stored.

Functional cookies

These cookies allow us to analyze website usage so that we can measure and improve its performance. No personal data is collected or stored.

Data protection declaration